David from KNOXVILLE, TN
Parts Used:
WR60X30922
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Ice built up around evaporator fan blades and blades chipped and broke. Refrigerator was making loud vibrating noises.
Removed ice bucket, and unplugged ice maker. Removed light cover. Removed ice maker. Pulled fan blades straight up and removed. Pushed new blades on to motor shaft. Fairly easy .
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
brian from CLOQUET, MN
Parts Used:
WR23X29170
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Interior light would not come on when right hand door was open
Remove the screws from the two door pivot covers. Remove the covers and set aside. Remove the screws from the control board; disconnect the electrical connections; remove the door light switch, install door light switch then reinstall everything.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from WEST HARTFORD, CT
Parts Used:
WR50X10069
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Temperature
I couldn’t repair the problem because the part that came did not have the clips to crimp on the end that go into the modular connection,
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barbara from EASTON, PA
Parts Used:
WR71X38291
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
The refrigerator door handle broke
I Googled how to fix a ge door handle. It was super easy. Just slide it up, take it off and replace by putting the new one in place and sliding down till it clicks.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michelle from LAWTON, PA
Parts Used:
WR55X40448
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Refrigerator kept shutting off
Pulled the fridge out. Removed the back panel over the mother board. Removed and replaced. Easy peasy and working well.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from AMELIA CT HSE, VA
Parts Used:
WR71X38291
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Door shelf cracked
Removed and replaced correct item received however one was cracked right out of undamaged properly packed box submitted claim and refund quickly processed by the seller recommend inspect upon receipt.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from SARASOTA, FL
Parts Used:
WR71X38291
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Replaced door shelf
Just placed the shelf on the door
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
QUOC-LOC from LYNN HAVEN, FL
Parts Used:
WR55X24064
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
The control board generated clicking noise. Temperature display wrong values.
On the internet forum I read that if the control board needs to be changed , do the same for the Run Capacitor/relay.
The Ge profile refrigerator was 15 years old. First I disconnect the power cord,
I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor.
Plugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rose from Dorr, MI
Parts Used:
WR60X30922
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Broke the fan blade when replacing the Evaporator motor
Took cover off, pushed blade on, and replaced cover
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michelle from Chimacum, WA
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
fridge to warm
followed part select video instructions
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chuck from TARRYTOWN, NY
Parts Used:
WR55X24064, WR55X10025
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
coils were icing up and refrigerator section was warm freezer was cold
Unplugged unit and removed vented cover over compressor section. The run capacitor is a simple fix 1 Phillips head screw and 2 spade wire connectors. For the temperature sensor I had to remove all drawers and the ice maker to remove the back cover to expose the condenser. Put a bowl at the drain stem in the rear of the unit and used a heat gun to defrost the coils on the condenser. Cut the wire about 3" from the sensor end . cut about the same off the new sensor stripped the wires put shrink wrap on each wire, attached butt connecors . heat gun for the shrink wrap and reassembled everything. Simple job that took about a half hour to do both. I will monitor the fridge for a couple of weeks to see if I need to change the control board.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Nesquehoning, PA
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Fridge wouldn't keep temp
My son replaced both temperature sensors and the fridge works great now!!! Like brand new again!!!!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Nick from Burnt Cabins, PA
Parts Used:
WR55X10025
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers, Socket set
Fridge/Freezer getting too warm
What an awesome site! After putting in my model number and finding the problem I was having, I simply picked the 2 parts that were most likely to solve the problem. I bought a defrost thermostat, and defrost heater. To a high certainty, they would solve my problem. They didn't however! I ended up having to buy a temperature sensor on another order a few weeks later when the problem resurfaced! My own fault. I should have bought it the first time. As others have written: the longest part of the job is defrosting the ice from the coil. One thing I did that I didn't see suggested: plug the drain hole below the coil. I put a couple towels in the bottom of the freezer and ran the hair dryer. Didn't take long. I read that the amount of water created will overflow the pan under the refrigerator, so I plugged the drain hole. Once you clean that mess up, the repair is pretty straight forward. Great site. Even through I had to make two separate purchases, I still saved a lot of money. Thanks!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edwin from Quincy, CA
Parts Used:
WR55X10025
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers
Refrigerator Running Warm, evaporator is not defrosting.
1. Removed and tested defrost heater, tests good. 2. Reinstalled defrost heater. 3. Removed and tested defrost over-temperature sensor, tests good. 4. Reinstalled over-temperature sensor using soldering iron, dielectric silicone grease, and heat-shrink tubing. 5. Removed the control printed circuit board and checked for blown fuse's, fuse's are all good. 6. Removed the defrost relay from the printed circuit board using soldering iron, bench tested the relay, it is good. 7. Soldered defrost relay back onto the circuit board, and reinstalled control board. 8. Removed and bench tested evaporator thermistor, the resistance is out of specification, ordered new thermister. 9. Installed new thermistor using soldering iron, dielectric silicone grease, and heat-shrink tubing. 10. Re-assembled refrigerator. 11. Installed temperature monitoring and recording instrumentation for 72 hour test. The defrost cycle is running correctly with a defrost termination temperature of around 90 deg-f. The defrost cycle ran twice while running the 72 hour test. 11. Removed test instrumentation and Put the unit back into service, The thermistor was the culprit. I bought the right part on the first shot, nice.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Durham, CA
Parts Used:
WR55X24064
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
compressor running and hot, refer and fridge room temp.
Watched a youtube on capacitors- though on a motor with a pulley, the symptoms were the same, motor running and pulley not turning-bad capacitor. Took a chance for a 17+ dollar part vs a new compressor. It worked.
Was this instruction helpful to you?
Thank you for voting!