Customer:
James M. from Belfair, WA
Parts Used:
WR55X10025
Difficulty Level:
Very Difficult
Total Repair Time:
More than 2 hours
The frig was not cooling in main section or freezer
I ordered 3 temperature Sensors Part#PS304103 and viewed the video. Got there, opened the frig. and it looked totally different and no place in any part of this frig. that took these sensors as viewed on the video. Totally baffled why these parts were listed for this frig. there was no place in this frig that would access for these parts. Serial # was HR443071.Maybe this model is out of date for these parts. Trying to find someone who can repair it. Any ideas???Purchased this GE in 2008. Model #is GSS25WSTFSS Thanks, for your help. JIM
Was this instruction helpful to you?
Thank you for voting!
Customer:
Brandon from Bruceton Mills, WV
Parts Used:
WR55X10025
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers, Socket set
Defroster stopped working and iced up evaporator coil
I have a GE Profile French door refrig. It's only about 4 yrs old and the defroster stopped working. I read the other repair stories and was able to narrow it down to either the temp sensor, defrost timer, or main board. The refrig section was up to about 47 degrees and freezer was around 25. I could tell it was trying to cool but couldn't. So I tried the temp sensor first. I cut and spliced the new sensor on the outlet of the Evap. Coil and it took about 15 mins. Turned refrig back on and waited. The coil started to ice over after about 5 hrs I left the back panel off so I could see if and when then heater kicked on. After about 8 hrs I looked in and saw a faint glow and water trickling down and running out the drain. Turned out the sensor was bad and wasn't telling the main board it needed to defrost. I would try the sensor if you are having the same issues before spending a lot of money on the main board, defrost heater and or timer.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Laura from Brentwood, MD
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Wrench set
freezer and refrigerator wasn't cold
Replaced all the sensors in both the feezer and refrigerator.Even though it colder now it still is not cold enough.Freezer won't freeze items but is cold and refrigerator still not real cold
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chuck from TARRYTOWN, NY
Parts Used:
WR55X24064, WR55X10025
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
coils were icing up and refrigerator section was warm freezer was cold
Unplugged unit and removed vented cover over compressor section. The run capacitor is a simple fix 1 Phillips head screw and 2 spade wire connectors. For the temperature sensor I had to remove all drawers and the ice maker to remove the back cover to expose the condenser. Put a bowl at the drain stem in the rear of the unit and used a heat gun to defrost the coils on the condenser. Cut the wire about 3" from the sensor end . cut about the same off the new sensor stripped the wires put shrink wrap on each wire, attached butt connecors . heat gun for the shrink wrap and reassembled everything. Simple job that took about a half hour to do both. I will monitor the fridge for a couple of weeks to see if I need to change the control board.
Was this instruction helpful to you?
Thank you for voting!