Customer:
Rich from san marcos, CA
Parts Used:
WR23X21444
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
No ice from door, but did have water
I got the wrong switch before so just need to put the right 1 in. Super easy, pop off old, plug in new, click back into place. Done. REALLY REALLY EASY for anyone to do
4 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Hugh from LADSON, SC
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Ice Maker stopped making ice.
Did the repair just as the instruction said, once I read it. The part I didn't read was that if the plug was under the ice maker, you had to take the wire out of the clip on the side. So, had to dismount ice maker, unclip wire, remount maker, plug it in. Still under 30 minutes. Thank you.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Wyckoff, NJ
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice maker stopped making ice
I had made a dry run at the repair after watching the instructional film provided by part select and it seemed easy enough.
The only problem was that i needed to use the electrical cord extender (provided) to adapt to my plug type. That presented a problm because it needed to be tucked up out of the way to allow the ice bin to clear. Just needed to be creative in how you wrapped the cord behind the ice maker unit before snugging the attachment screws.
Cranking out ice like crazy.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fred from LA QUINTA, CA
Parts Used:
WR17X22070
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Replace water filter with bypass plug - filter is redundant with home osmosis system
If you have a reverse osmosis system for filtered water system in your home that also feeds the refrigerator, using another water filter in the refrigerator is redundant, so GE makes a Water filter Bypass Cap that allows you to run using the already filtered water without needing to expensive water filter. FIRST - using a phillips screw driver remove the toe kick plate at the bottom front of the refrigerator - two screws - one on each side of the plate that extends the entire width of the refrigerator. SECOND - Locate the water line (should be right in front) and the valve to turn off the water. Turn valve clockwise (right) until completely closed. Then test by attempting to fill a glass with water using the dispenser on the door. If any water continues to come out, continue turning the valve (without forcing it) clockwise until it has been turned as much as possible. If water still comes from dispenser, locate the source of the water line - most likely from under the kitchen sink. There should be another valve under the sink, or simply turn off (turn the cold water valve clockwise) until water cold water completely turned off. Test again as required. THIRD - clear the top right hand back shelf directly under the water filter screwed into the ceiling of the refrigerator in the rear top right side of the refrigerator. Place a small towel under the water filter, and slowly turn the filter 1/4 turn clockwise without using force. Continue turning until the full 1/4 turn is complete and the filter will drop down without pulling. Place the old filter upside down in the sink, thereby allowing the filter to drain any water present in the filter. FOURTH - remove the filter plug from package, notice notches in top of plug that align with gaps in the area where a filter would typically be screwed into the filter location in the ceiling above the top right shelf in the refrigerator. After aligning notches in the bypass plug with gaps in the screw mechanism, carefully turn the bypass plug 1/4 turn counter- clockwise - at which time the bypass plug should be firmly installed. FIFTH - Reverse step SECOND, and turn valve Counter-Clockwise until valve is completely open. Test to ensure no water is leaking from the Bypass Plug. SIXTH - Finally reverse step FIRST by reattaching the toe kick plate using the two phillips screws removed in Step FIRST. NOTE: The Bypass Plug is quite inexpensive, but after adding shipping from Canada - the cost is about the same as purchasing a new filter for the refrigerator. :-(
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Roger from Colleyville, TX
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
No water through door dispenser
Replaced flapper valve per website instructions. GE factory technician took two weeks to get here, charged over $100 for the call and told us we needed a new refrigerator door at a cost of over $500 to fix the problem. We sent him packing. After visiting the PartSelect website, the $5.88 PartSelect flapper valve fixed the problem. Amazing.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from ROSEMOUNT, MN
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of freezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Myrtle Beach, SC
Parts Used:
MWFP
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Yearly replacement of filter
Moved stuff out of my way on the top shelf, reached in and turned old filter to remove. Filled new filter with water, lined up and turned to lock in place. Whew, never thought I would get that job done. :-)
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Shelly from WATERLOO, IN
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The ice flapper would not go close .
remove the front of were the ice and water comes out
then un scerw 4 scerw and the solenoid slides out unhook the wires and put the new one in
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Benjamin from Goldsboro, NC
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice flap in door wouldn't close
Take the face (the part with the buttons on the outside) off, disconnect wired connectors (three), take the screws out of the part behind that (4), and then find the solenoid value (on the right). It's attached with three screws. Mine was rusted beyond belief. I knew this was the problem, ordered a new solenoid valve, put it back in place with three screws (use new screws that fit, not the old rusty ones if possible). When testing, make sure you give the flap a couple of seconds to close. There is a delay, and I initially wasn't patient enough so I had to disassemble and assemble an extra time because of this.

Simply put: If your solenoid value is rusted and the value won't operate smoothly, order the part and install it. This is as easy as any repair could be.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Coppell, TX
Parts Used:
WR62X10055
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice dispensor door would not open all the way and did not close
I used a mirror to locate the two small plastic tabs located on the underside of the ice dispenser light. I used a small flat blade screwdirver to push the plastic tabs forward to release the ice/water selector unit. I read about someone that did not see the tabs and ended up removing the inside of the freezer door, a two hour task! The ice and water control unit then slides out. remove the four rusty screws holding the dispensert and ice chute, the selenoid isthen easy to see.
Just replace the solenoid if your are having problems, I tried to lube it but to now avail. There is some rust in there so good time to clean up and put new screws in. Be care when removing the plastic lock tab on the circut board it breaks easely. If it does no big deal just make sure the connection is pushed in all the way. test your handy work before buttoning up. The solenoid comes with a new plunger so don't worry about cleaning the old one. The screws do not come with.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rick from VACAVILLE, CA
Parts Used:
WR17X11653, WR17X10706, WR02X10585
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
ice door not closing
looked at the video you supplied for repair.. that made it so easy to repair the problem. I felt quite confident in myself after the video.The repair went smoothly and the refridgerator wotks super thank you so much Rick
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bryan from Fairfax, VA
Parts Used:
WR62X10055
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer frosting up around ice dispenser chute.
Ordered new solenoid so the flap would close. That did the trick.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Anaheim, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers, Wrench (Adjustable)
The icemaker quit making ice and the water started forming on the bottom of the ice bucket.
First I removed the electrical plug from the back of the freezer that plugs into the icemaker. I then removed the two hex head screws that hold the icemaker to the wall of the freezer and removed the icemaker. I removed the plastic cover, which incidentally protects the gears, by prying it off with a srewdriver. I removed three small nuts(7mm) which holds the internal cam in place. I removed the cam by pulling it off the shaft. Once I got the part from you folks I reversed the procedure that I just mentioned, and put the icemaker back together. It works great. The part with shipping was around $16.00. A new icemaker was roughly $159.00. If I would have called a technician it would have cost around $300.00 to repair.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Stephen from Los Angeles, CA
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Door flapper would not self-close
I replaced the original solenoid, which had rusted into one solid piece. OMG how easy was that!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
john from st aug, FL
Parts Used:
WR62X10055
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
the cecular door for the ice was geting stuck opened
with a small screwdriver push in tabs in upword movement to remove the face cover for the three botons of ice crushed ice and water .
once removed remove four screw to take out the circular door .
solinoid plunger will be atached to the door and it has to screws holding the solinoid .
instolation is the oposit steps of removing the part
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!