- Roger from CAMARILLO, CA
- Parts Used:
- WR17X22070
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Leaking around filter bypass plug
Took old one out with my fingers. Put new one in with my fingers.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- NICK from COCOA bEACH, FL
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice dispenser door will not shut completely
I removed the door cover plate and disconnected the circuit board, then four screws. The part was corroded in place. Upon removing three screws and cleaning the surface, the new part was an exact fit, replaced it and everything works like new.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- jeff from stillwater, OK
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
solenoid quit working
repair was easy, just removed control panel and removed screws from solenoid, switched out with new, was done in minutes
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from W Berlin, NJ
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice forming around shoot. Flapper door not shutting letting warm air in.
I followed they instructions from the other "do it your selfers" but only replaced the solenoid. This was the cause. Rust was keeping solenoid plunger from moving and this held the flapper door open. Very easy to repair!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joanne from Fort Smith, AR
- Parts Used:
- MWFP
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Auto water stopped working, found that filter needed replacement
Unscrewed old cartridge, ordered new cartridge, installed new cartridge by following very simple instructions. Took only one day for part to arrive from PartSelect although I paid for cheapest shipping, which was "ground." I was amazed!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- david from LANSING, NC
- Parts Used:
- WR62X10055
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
broken Ice maker dispenser
with a philips screw driver and that's all it was that easy
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dennis from Rogers, AR
- Parts Used:
- WR17X11653
- Difficulty Level:
- Difficult
- Total Repair Time:
- 30 - 60 mins
Watched video on flapper assembly replacement looked real ready. Video failed to mention ice dispenser trim was glued in place . Had to buy real small paint scrapper that would fit in dispenser outlet to free inside edge of trim piece. Once I got it all loose job went very easy.
Use small putty knife to cut internal sealant on ice maker door trim piece. Then you can easily remove it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- J Stephen from BETHESDA, MD
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Warm air enters ice dispenser on door
Replaced flapper. Followed the video. The lamp caused the removable plastic bracket (which supports the control panel and the ice chute) to fuse with the plastic frame in the door. Eventually broke the fused plastic, removed the bracket, and filed the rough broken plastic before reassembly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephen from Richmond, VA
- Parts Used:
- WR62X10055
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Socket set
Ice wouldn't come out of door. It backed up in door
I followed the instructions on a posted desctiption. It workded perfectly. Replacing the inner door panel was not as difficult as described. Just start the process with the screws in the middle of the door. Those two screw holes were not slots. All of the remaining screw holes had slots. I installed all of the door screws before tightening any. I workded right the first time.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Maurice from PALM BCH GDNS, FL
- Parts Used:
- WR62X10055, WR17X11653
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set
Ice dispencer door does not close properly causing ice formation
Used the instruction provide by Part Select, which are easy to follow.
When it came to replacing the Solenoid, the two bottom screws were easy to remove, The third screw (located on the top) needed lo be loosened, That screw was very difficult to remove because it was rusted, and I had to replace it.
I suggest that a spare screw should be supplied wit the solenoid.
When it came to replacing the Solenoid, the two bottom screws were easy to remove, The third screw (located on the top) needed lo be loosened, That screw was very difficult to remove because it was rusted, and I had to replace it.
I suggest that a spare screw should be supplied wit the solenoid.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from NEW YORK, NY
- Parts Used:
- WR02X10540
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set
noisy refrigerator
I followed your video and completely dismantled the refrigerator evaporator motor, fan, brackets, and grommet, I completely cleaned the refrigerator including the cooling coils. I then ordered the evaporator motor ,fan, grommets, lid bumper, and brackets. The order would take a week to arrive. In the meantime I cleaned and reassembled all the old parts, waiting for the new ones to come. Guess what! The refrigerator was quiet as a mouse. I really did not need the new parts, but I kept them anyway just for good luck. Not bad for a refrigerator that's twenty four years old.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Randy from VALLEY CENTER, CA
- Parts Used:
- WR02X12008
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- More than 2 hours
Loud whirling noises when the motor started up, then they subside (and stop) in a short time
I have not yet done the repair. After watching this repair video two problems came to mind. First I only ordered one grommet not knowing that there were two (or more I don't yet know). The second problem is that this video must be for a fridge from like the 1940, but it looks NOTHING like mine from 2008. The manual shows a bazillion parts and frankly I'm just a wee bit afraid to get started, and I am generally very handy, buuuttttttttt I don't know about this one
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gail from LEXINGTON, SC
- Parts Used:
- WR17X11653
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- More than 2 hours
Thought flapper in ice dispenser was problem. - more serious, more costly - not a DIY! New fridge here we come!
Opened, discovered not flapper but more complicated
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Brentwood, CA
- Parts Used:
- WR60X10185
- Difficulty Level:
- Easy
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Screw drivers, Wrench (Adjustable)
My son's Refrigerator
I started out replacing a bad thermostat, no problem,
when I hooked up the water, I found that the water resovior had a leak.
I replaced the resovior, easy fix, but I had to buy two 5/16 brass couplers.
then I found that the box would not get below 10 degrees, and the suction pressure was very low.
I figured that the fan motor was burned out, so I opened up the access covers, the fan motor was hanging there with broken mounts, so I replaced the motor, and repaired the mount.
Everything works great now, The parts shiping was very fast, I was impressed.
I thought I was going to get away without fixing everyones
HVAC problems when I retired.
Friends and family still remember that you are the HVAC man.
Tom
when I hooked up the water, I found that the water resovior had a leak.
I replaced the resovior, easy fix, but I had to buy two 5/16 brass couplers.
then I found that the box would not get below 10 degrees, and the suction pressure was very low.
I figured that the fan motor was burned out, so I opened up the access covers, the fan motor was hanging there with broken mounts, so I replaced the motor, and repaired the mount.
Everything works great now, The parts shiping was very fast, I was impressed.
I thought I was going to get away without fixing everyones
HVAC problems when I retired.
Friends and family still remember that you are the HVAC man.
Tom
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Zephyrhills, FL
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Screw drivers
Leaking And Making Stalactites
Had to defrost the freezer to melt off all the ice before servicing. Once that was done the icemaker replacement only took about 15-30 minutes to complete. The new icemaker came with many accessories and adaptors that were not needed and the instructions were based on replacing an older model and not really clear for my model. They mentioned not being able to use the new stripper but it was exactly the same as the old one so I left the new one in place. All in all it was easy and did the job.
Was this instruction helpful to you?
Thank you for voting!