Models > GFE24JGKGFWW > Instructions

GFE24JGKGFWW General Electric Refrigerator - Instructions

Jump to:

All Instructions for the GFE24JGKGFWW
1 - 15 of 99
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
michele from North Smithfield, RI
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers
my refigerator was warm but the freezer was cold and working correcttly
I went to a GE repair center to explain my problem, the service center reccomended that I have a techinician come out o look at it. $75.00 for the visit and what ever labor and materials wuld cost.

I went on line to see if there were others having this same problem and found that there were many with the same problem.

After reading some of the ways that people found out what was wrong ...it became a matter of three components, the timer, heater or thermostat.

I tried the most common component and the less expensive one first , the thermostat switch I installed it very easily snipping two wires and attaching the news using wire nuts I used the diagram on this website to pinpoint the component and there has not been a problem since.
272 of 342 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Menomonie, WI
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
refrigerator was getting too cold
I removed the old temperature sensor by cutting the wires. I attached the wires of the new sensor with wire nuts and mounted it in the same bracket.
143 of 199 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
DOUG from MARYSVILLE, OH
Parts Used:
WR60X10185
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Evaporator motor sounded like wind in the trees howling
I had to remove all of the shelves.....part of the ice maker.....the rear cover over the freezer coils.....There were two wires that came from the back of the freezer that were also incorporated with the fan motor plug from the factory....This caused me to cut all of the wires from the new motor and soider them to the existing plug and shrink wrap the connections. If GE would have supplied two new ends I could have cut only those wires added the ends and inserted them into the new motor plug thus eliminating an extra hour and a soildering iron,,,,In my case not a big deal however not a project for those who have trouble with repairs using these type of tools.
111 of 137 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Romeo, MI
Parts Used:
WR60X10185
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
The evaporator fan motor stopped running, freezer was warmer than normal
First ,I placed all the frozen food from the freezer into the lower fridge compartment. Removed the main shelf. Removed the ice cube tray shelf. Removed the center plastic covers using a nut driver. Removed the complete inside back wall of the freezer to get access to the fan. Simply removed about 5 screws, and cut 3 tie straps that held the wiring in place. Unplugged the fan connector and removed fan with its brackets and placed them on the kitchen table. Then used the nut driver to remove 2 screws which hald the fan to its bracket. Simply pulled off the fan blades and pressed them onto the new motor. Mounted new motor onto the bracket. Reinstalled the fan assembly back into freezer. Reconnected the wiring and the fan began to run... BE CAREFUL NOT TO TOUCH THE FAN WITH YOUR FINGERS!
Finally replaced all the covers, panels, and shelf etc. and everything is once again nice and cold.
65 of 87 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Anthony from Murfreesboro, TN
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
fridge side freezes some items
went to your website and viewed exploded view to find the sensor( there are two I just picked one to replace for now), pried the cover off carfully and pulled out the sensor. I snipped the wire in the middle leaving plenty to work with. I shortened the wire on the new piece, spliced the wires together and with some 3M rubberized, tape wrapped them up, replaced the sensor back into the cover and snapped in place.
54 of 75 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Mancos, CO
Parts Used:
WR55X10025
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
freezer cold / fridge warm
put fridge into test mode, failed One sensor. Took it out, Tested it, Ordered part also picked up splice kit from electric store spliced it truned on and good to go
46 of 54 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Madison, CT
Parts Used:
WR60X10185
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
The freezer was whining and growling like a baby
I replaced the motor that runs the fan in the freezer compartment. Had to remove a number of shields to get to the fan and then some wires and screws to get at the motor. It came with a plug with 4 wires in it and I was supposed to pull 2 wires out of the old plug and place them in the new plug. Long story short the pins would not extract from the plug and the wiring harness was molded in solid plastic, so I ended up cutting the 4 wires to the motor and splicing in the new one and taping them with electrical tape. So far no more moaning and the ice cream is still hard, so I think we nailed it.
43 of 54 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Milton, FL
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Freezer would not defrost correctly
Took panel off back of inside of freezer section, took off old sensor from the evaporator, spliced new sensor into the existing wires, waterproofed spliced connections, snapped sensor back onto evaporator, then put panel back on the inside of the freezer. Really, it took only 10 minutes to fix. Now refrigerator defrosts like it used to, and temps have settled in at specified temps.
32 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joe from Suffolk, VA
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Ice & Ice Cream would melt and refreeze
Noticed the problem in November 2009. Replaced Hi Limit Sesor for Defrost thinking it was the freezor temperature sensor. Did not fix the problem. Replaced Motherboard. Did not fix the problem. Called Sears Repair. They mis-diagnosed the problem and told me it was the sealed system. I doubted them and sent them home. Replaced the correct freezer temperature sensor that connects to the motherboard. FIXED.
Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.
30 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from College Station, TX
Parts Used:
WR60X10185, WR02X10668
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Pliers, Screw drivers, Socket set
Freezer and fresh food compartments too warm
After having replaced the main control board and three thermistors, the fridge was still having difficulting getting cold enough - it wouldn't get colder than 15F / 42 F. Uniform frost on the evaporator coil ruled out a sealed system leak, so the remaining culprits were the either the evaporator fan motor or the compressor.

I read that a failed control board is almost always the fault of a bad evaporator fan motor, so this item was the most likely suspect.

To get to the evaporator fan motor, I had to remove, in this order:

1) Icemaker
2) Auger motor and brackets
3) Icemaker bracket
4) Freezer lights and bulb sockets
5) Evaporator panel
6) Evaporator plenum cover
7) Evaporator fan motor bracket

The greatest difficulty lay in swapping the new fan motor harness. Two pins in the harness connector were used for the evaporator thermistor.

I had to carefully cut through the old connector (using a Dremel) to extract the crimped-on pins for the thermistor, then reuse them on the new connector.

The fridge is now maintaining -5 F / 35 F in the freezer / fresh food sections.
25 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
ronald from kissimmee, FL
Parts Used:
WR60X10185
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Very high pitch whine. Not real loud but really annoying.
First I hired a repairman and he said that it was in the unit and would not be worth the expense to fix.

I started to research on the net and this was one possible source. ( evaporator fan). I had to take it apart to verify it. Then put it back together to use until the part came.

The next time went much faster as I did not have to take near as many screws out to access the fan motor. Very Happy to have it working fine again as a new relacement would cost $1200. Thanks much. Ron
22 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Windham, NH
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers, Socket set
Freezer and fresh food section getting warm due to inside coils frosting over.
No self defrost. Measured heater coil with ohm meter which was OK (not open). Ordered 2 temp sensors (there are 2 in freezer, 2 in fresh food sections). The original and the new all meaured ~150 ohms. Replaced one by one. This did not fix problem. Ordered defrost thermostat. Original measured ~150 ohms - new one was ~100 ohms. Unpluged refridgerator. Removed coil panel (4 nut screws) in freezer and light cover (1 small phillips screw). Locate defrost thermostat clipped to top of coils (orange / pink wires). Cut wires and unclipped thermostat. Stripped insulation off of wires and reconnect using wire nuts. Clipped thermostat back to coils. Ran refridgerator without panel on coils to see if coils frosted up again and listend for fans/compressor to stop ( took hours). Opened freezer and viewed glow of defrost heater. Problem resolved.
23 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jason` from Colchester, CT
Parts Used:
WR60X10185
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
freezer fan failing; veried speed making whirling sounds
First, I removed all the shelves and the light guard. Second, I removed the nuts that held the fan guard and the freezer back in place (2 just under the fan guard and removed the freezer back. Third, lifted fan guard out of way (being very careful not to crack it..... cold plastic). Fourth, unpugged fan from pug then removed nuts that held fan bracket in place...removed fan. fifth, then removed fan blade and remove fan motor from bracket, removed two wires that went to freezer light (pay attention to where they go) and installed them into the new wireing harness. Sixth, installed fan blade on new motor, bolted new assembly in fan bracket, plugged in and reistalled fan into the freezer, replaced fan guard and freezer back (reverse order of above) and then replaced freezer racks. works beautiful.
14 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
lk from carlsbad, CA
Parts Used:
WR60X10185
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Loud knocking noise with the evaporator fan
I had taken the noise long enough and wanted to get this repaired. I didn't want to pay a repair man hundreds of dollars to do it so i decided to do it myself. I went on to YouTube and found a few videos that showed me how easy it was to do (very helpful).

I wasn't so sure all that noise would come from the Evaporator Fan motor so i ordered it and took the chance. For the small cost, it was worth the try.

All went well accessing the unit and removing the old part. Very fast indeed. However, the snag came when i went to plug in the new part electrical to the existing electrical adapters. The old part had 4 lead connections. The new part had 6. and the wires on the new part were different colors than the existing. I had to use some logic and courage to cut the wires on the new part and rewire the old adapter to this piece. Luckily, i wired everything correctly.

Calling Part Select got me a phone number for the parts manufacturer to help with the splicing but i opted to do it on my own.

The result is i have a noiseless refrigerator again. What should have taken 10 to 15 minutes took half an hour because of the wiring but overall, very easy.
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from BENICIA, CA
Parts Used:
WR01X39781
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
lower pull out drawer handle fastener to freezer was broken on one side.
I ordered the plastic fastener, that held the handle to the freezer door.
after I received the part I used a screw driver to attach the fastener to the door. Then I placed the handle onto the fastener and bumped the handle with my hand to the left. this attached the handle to the door.
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GFE24JGKGFWW