CWE19SP2NBS1 General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Jason Mcgee from Catawissa, MO
- Parts Used:
- WR55X10025
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
freezer would not defrost or maintain temperature
luckly i have a bit of experience in refrigeration im an hvac technician by trade. this repair was a bit tricky in that i did not know at first if it was a Temperature Sensor issue or the main control board. I had tested the defrost termination thermostat and the defrost heater and as i suspected they were ok. Next i wanted to test the thermistors (temp sensors) it is hard to find technical data on these fridges. I needed to test the thermistors resistance @ a certian temperature to ensure they were working properly but where do u get such data? I also wanted to know some information about the logic programmed into the board (i.e when do you initiate defrost etc. . .). I had no such luck so i figured since i tested the defrost heater and thermostat and they were ok and all of the evap fans and such were working i'd order a circuit board and new thermistors. Got the CORRECT PARTS from this site in 2 business days and my fridge is working great! changing the parts was really easy, figuring out which parts to change was the only difficult thing about this job.
Was this instruction helpful to you?
Thank you for voting!