Paula from Boca Raton, FL
Parts Used:
WR72X209
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
slides were broken and draws cracked
Emptied the old draws and removed the old sliders. Took time to screw the new ones in. The draws are not as nice as the original ones.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alan from Spring Valley, IL
Parts Used:
WR60X177
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Socket set, Wrench (Adjustable)
The motor was making a thumping out of balance sound.
Naturally you have to push the frig from the wall and unplug it form the wall outlet and while you are removing and installing the old motor and installing the new motor. Do not open any of the frig and freezer door untill you are finished and you plug the power cord back into the wall outlet. Remove the lower back panel with a screw driver or a 5/16th hex driver. It is a kind of carboard. Once all the screws are out of that panel pull the top out from behind the steel above and then pull it out from the bottom and set it aside. Unplug the power line off of the motor. There are 3 separate brakets holding the motor in place. 1st remove the fan from the motor by romving the finger nut off the motor shaft and then remove the 1st bracket screw from the bracket all the way. Then use a light to see the other 2 screws and you will see that you do not have to take them all the way out like the first one. Just loosen the other 2 and then turn the motor and brackets counter clockwise and then pull the motor and brackets all out as one from the right hand side of where the brackets were mounted. I took the motor and brackets to the counter and removed te brackets from the motor and installed them to the new motor making sure that the bracket with the one screw hole in it is mounted at the right place so that when you reenstall the motor and brackets will let the motor wire connector be the closest to the outside where you can replug the power cord back onto the motor. Install the fan onto the new motor with the new finger nut that comes with the new motor. replace the back panel and pkug in the power cord fot the frig and let it run. Mine ran a lot quieter after the new motor was plugged in. Have fun if you have to do it. It is worth it.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frank from Villa Rica, GA
Parts Used:
WR2X4550
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
The drive cup was old,worn,slipping and appeared to have never reached deep enough.
I removed the front of the unit assembly and removed the entire auger unit and drive assembly. I married the old drive cup and new drive cup back to back using vise grip pliers, drilled 4 3mm holes, installed 4 phillips head stainless steel screws and, using an emory wheel, ground off the exposed screw ends. I then re-installed the drive assembly and auger unit. This increased the length of the drive cup allowing the drive to fit without any slippage. The entire cost was less than $18.00 including shipping and screws and took about 1 hour. It works great.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Denison, TX
Parts Used:
WR17X4341
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers
The ice auger was rusting getting rust on the ice cubes. This also hindered the auger from working properly.
I removed the ice container with the auger inside. I removed the front panel, then the auger and housing. I had to clean all of the parts that had rust on them. I got some of the parts mixed up and was having a hard time putting them back where they belonged. I went back on the PartSelect web site and with my IPad and opened the exploded view of the parts. This enabled me to put the auger back together. It works perfectly now. Saved a lot of money by doing it myself. Thanks PartSelect.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Central City, KY
Parts Used:
WR50X55, WR49X391
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Screw drivers
unit s coils would freeze up
made sure def. timer was operative. removed back panel of freezer section. found heaters bad, replaced elements also replaced sensor. I am 72yrs old so it took me longer than it should have,PartSlect send me the exact replacements parts that was needed. one day service
Was this instruction helpful to you?
Thank you for voting!