Kenneth from Milford, CT
Parts Used:
WR23X21444
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer Light switch broke
Your instructions were "spot on"! Pried out broken switch with screwdriver-reinstalled new switch. Very easy! Ordered on line on a Wednesday new part arrived on following Saturday-Great service and will definately use again. Highly recommend PartSelect!
8 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lloyd from PITTSBURG, CA
Parts Used:
WR55X24064
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Refrigerator to warm
Instructions say run capacitor is by motor, but on this frige its in the refrigerator compartment. The capacitors looks different, one square and the other long
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Benjamin from Pittsburgh, PA
Parts Used:
WR72X10153
Difficulty Level:
A Bit Difficult
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Frame lower pan had cracked severely in several places
The only tough part was getting all the other parts off the old frame so that I could attach them to the new frame. In particular, the center rail required a lot of prying to remove, and I was concerned that it would break. Also, removing the sliders for the crisper drawer vents was a bit tricky; I ended up having to break the tabs that hold the vent covers in place, removing the vent covers, then removing the sliders.

Once I had reclaimed all the other parts, putting the new assembly together was pretty easy. My only concern is that the frame does not quite seat into the fridge in the correct way, it rides over the support knobs at the front.
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jonathan from NEW ORLEANS, LA
Parts Used:
WR55X10942C
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Refrigerator and freezer would stop cooling. Would happen suddenly without warning. Reset of refrigerator would solve the problem and it would run fine for several days before doing it again.
Only tool I used was 1/4 inch socket. Using the 1/4 inch socket, the screws were removed from the panel covering the control board. (this is on the back in the lower right corner). When this panel is off you are looking at the control board. Next remove all the plug in connectors. Don't worry about remembering where they go. They all are different and can only go in their specific place. After removing the connectors, pull the board out. Replace the plug in connectors before putting the new board back in , then snap the board back into place.(held in by four pins). Replace the cover.
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ron from ORANGE, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Unit had stopped making ice
Ordered the icemaker replacement. unplugged the unit, followed the simple instructions and got it done in less than 30 minutes. It did take a LONG time to start making ice. But it's working now.
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from White Pine, TN
Parts Used:
WR55X10942C
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Would not cool top or bottom
Everything looked to be working but the compressor. As a pro checked every thing came down to a relay on the main board.

Just removed cover from back top left. marked and removed all wires. removed old board and installed new board very easy. Must read paper sent with it,
you may need to cut wires on some models.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
louis from floral park, NY
Parts Used:
WR55X10942C
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
evap fan not working.
first i removed the three screws that covered the circuit board that was bad. then i removed the 6 connectors that went from the refrigerator to the board then popped out the old board , popped in the new board reconnected the circuit connectors covered everything back up and my refrigerator is back on line. this all took about 10 to 15 minutes time ... thank you for your product it really did the job..
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chip from Mandeville, LA
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
broken auger in the bucket assembly.
I ordered the wrong part, the ice maker assembly, because your diagram was not marked properly. I returned the part and you credited my account. Thanks. Ordered the new bucket. It worked fine. Now I have ice and crushed Ice whenever I want. Thanks.

p.s. I didnt use any tools, but to satisfy you I select nut driver.
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Keller, TX
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice Maker would not fill.
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.

Went ahead and installed the unit, using the supplied electric cable adapter.

A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dean from Folsom, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The Icemaker failed to make ice
I pulled the refrigerator away from the wall and turned off the water to the refrigerator and unplugged it from the wall. After removing the icebucket from the freezer I located the mounting screws, loosened them, unplugged the electrical connection below the icemaker and carefully removed it from the freezer. I unpacked the replacement icemaker, matched it against the original and attached the electrical connection adapter. Using the slots provided on the new icemaker I placed it over the mounting screws after aligning the water inlet pipe properly. I tightened the mounting screws while maintaining the icemaker in a level position. I plugged in the electrical connector. Then I replaced the icebucket, plugged in the refigerator back into the 110VAC outlet, turned on the water and repositioned the refrigerator in it's normal position.
8 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from Fresno, CA
Parts Used:
WR02X11706
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
broken dairy door cover
removed old one and installed new one. 30 seconds.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Johnnie from KANSAS CITY, MO
Parts Used:
WR55X10942C
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
The Ground wires wasn't in same location on board
i had to improvise And relocate ground wire to get a proper ground .. That's all , the video was a GREAT HELP...
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Clarksville, GA
Parts Used:
WR55X10942C, WR55X24064
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Electric surge from lightening strike close to house
Obvious that main electronic board was fried. Refrigerator and freezer both not working although fan was running. Replaced main board and run capacitor. Compressor not running. Pulled starter relay and checked compressor connections for continuity. Checked ok. Ordered starter relay and installed with new capacitor. Compressor started and has been running quiet and cold ever since. Thanks to videos on partsselect website for offering the confidence to try the fix myself. Total spent on parts and shipping,$350. I had electric provider install surge protection behind meter for a cost of $5.70 a month. Hope it works as advertised.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from San Marcos, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
no ice made
Performed self test.turned off ice maker switch four 5 minutes.Then turn on switch,within 10 seconds,pushed ice paddle 3 times,with 1 second in between each push.Push all the way back and release. Ice maker should cycle and squirt water. My ice maker did neither.I unplugged cord from fridge.So i replaced the ice maker.After a couple of screws had ice again !
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tim from Mountain View, AR
Parts Used:
WR55X10942C
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Ice cream melting, lettuce freezing
Removed the back cover over the control board, and made sure that the board was the same. It didn't look exactly the same, but figured that it was the same, just updated. Took out the board, moved the wires to the new board and reinstalled. Plugged it in and it came on, so I reinstalled the cover. Seems to be working to this day.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GBS20KBRCWW