TPS24BICGBS General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Charles from Rose Bud, AR
- Parts Used:
- WR50X122
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench set
Refrigerat
rerfrigator side not cooling After determinating that the defrost timer was running I turned it to defrost and watched tosee if frost started to melt. When it didn't I checked the heater with ohmeter, checked OK, so the only other component in the defrost system is the thermostat. Then just a matter of cutting and splicing wires and snapping the new thermost in place
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- robert from WOONSOCKET, RI
- Parts Used:
- WR51X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Freezer coils were iced up,was not cold enough,suspected the heater was the culprit
I had looked at videos on you tube,it looked simple enough. I mostly do my own repairs so I gave it a shot. the job went well,if you do not fix things around the house don't try to do the repair,find a handyman in your neighborhood to help you out,cheaper than calling a refrigeration man. It is not that hard to do.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kathrine from FORT MILL, SC
- Parts Used:
- WR60X187
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set
There was a warm spot at the front edge of dividing wall. The fan motor was not working.
I followed the directions of Steve on the installation video. He makes it easy to do the repair with his step by step description of the installation. I have repaired three different aging appliances with help of Steve and PartSelect's very helpful Customer Service.
I wish Steve a wonderful retirement and hope PartSelect can find someone as easy to follow for future videos. The videos are priceless for the repairs.
I wish Steve a wonderful retirement and hope PartSelect can find someone as easy to follow for future videos. The videos are priceless for the repairs.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from San Marcos, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
no ice made
Performed self test.turned off ice maker switch four 5 minutes.Then turn on switch,within 10 seconds,pushed ice paddle 3 times,with 1 second in between each push.Push all the way back and release. Ice maker should cycle and squirt water. My ice maker did neither.I unplugged cord from fridge.So i replaced the ice maker.After a couple of screws had ice again !
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from St George, UT
- Parts Used:
- WR51X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator temp went to 60 degrees
Freezer section defroster heater was inoperative.
turned off the refrigerator by turning the right knob in top rear refrigerator to 0.
Used hose on a vacuum sweeper blower side to feed warm air into the bottom rear section. Removed the top plastic panel behind the ice maker to allow air flow to exit through the fan to defrost the freezer coils.
Placed a flat oven pan into the area beside the vacuum hose and sponged up the melted frost water. After 30 minutes, water ceased to drain.
Removed freezer shelves, and 5 screws on rear freezer wall. It took about 2 minutes to remove the heater & braw assembly at the bottom of the coils. 2 screws have to be removed and wires just clip off and back on again. Replaced the 2 screws.
Replace rear coil wall cover and turn on the refrigerator to 5 to 7 and replace cover and shelves.
turned off the refrigerator by turning the right knob in top rear refrigerator to 0.
Used hose on a vacuum sweeper blower side to feed warm air into the bottom rear section. Removed the top plastic panel behind the ice maker to allow air flow to exit through the fan to defrost the freezer coils.
Placed a flat oven pan into the area beside the vacuum hose and sponged up the melted frost water. After 30 minutes, water ceased to drain.
Removed freezer shelves, and 5 screws on rear freezer wall. It took about 2 minutes to remove the heater & braw assembly at the bottom of the coils. 2 screws have to be removed and wires just clip off and back on again. Replaced the 2 screws.
Replace rear coil wall cover and turn on the refrigerator to 5 to 7 and replace cover and shelves.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- barry from HARTFORD CITY, IN
- Parts Used:
- WR51X10055, WR50X122
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
warm refrigerator, and freezer not defrostt
i replace the defrost thermostat and defrost heater and bracket assembly. i did not know what was wrong with the refrigerator until i found your web site. i would like to thank all the friends who explain this process. this save me the price of a service call. this was a very easy job
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ELLIOT from COS COB, CT
- Parts Used:
- WR60X10009
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Freezer Evporator Fan Motor Failed
Unplugged power supply, dis-assembled fan motor housing, opened back panel partially to remove entire fan unit, took off fan, put onto new motor, re-assembled in reverse order and plugged in power supply. Wha la!! Everything running smoothly, original settings '3' for freezer '5' for refrig and evp fan motor running about 1 hour then shut off all night until next morning came back on as usual. Thanks parts select for making a headache go away so quickly. Ordered part online, received tracking details, received part in 3 biz days, and installed in 30mins. Refrigerator good as new, infact, better because I cleaned up freezer of food spills, and wiped clean all trays. Brgds elliot rund satisfied consumer, repeat customer for future.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marie from Elk Grove Village, IL
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
My ice breaker started leaking and making noise anf the stripper broke.
I ended up needing to order a new ice maker because the one I had is discontinued. I'm a 65yr old grandma and I did it myself!!!! The hardest part was finding the tool to loosed the nuts. I took the old one out and just put the new one right in it's place. Easy as pie.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Karen from SAN ANTONIO, TX
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice maker filled too full and ice froze in the basket and a piece was broke on the icemaker itself.f
My son did it , and showed me what he did when he was finished.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- mark from butler, PA
- Parts Used:
- WR51X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
The freezer keep freezing up, and food in fridge was freezing in the bottom.
Called the repair guy, he came and said the heater was ok and changed the thermastat.Well that didnt work and the heater looked real bad.So i got one and changed it. Well that worked for two weeks, next i got the motherboard. I looked into it and they have alot of problems with them.And My water and ice machine quitto, so i got one an put t in. So far its not freezing, its been two weeks. But my water and ice machine still wont lite up or work.I was told not to buy Ge buy a service guy before we got it. But the wife went with her cousin and when they got back that is what she got.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from PLYMOUTH, MA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Ice maker needed replacement
Unplug refridge then loosened two bolts holding old ice maker. Lower then unplug and removed. Plugged in new harness and tightened two bolts to secure new ice maker. Plug in frig and wait for ice.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lynn from MOUNTAIN HOME, ID
- Parts Used:
- WR30X10093
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Made ice would not eject from ice holder bin
removed broken bin , slid new ice bin in closed door. I bought the complete part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Catherine from Stamford, NY
- Parts Used:
- WR51X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
iced up freezer coils
took out heating element while ice was still on coils..replaced w/new one, thought it would go on to defrost right away ,but freezer had to run it's cycle . Then after about 4 hours all ice was gone and all went ok..back to normal and it is now set on #4 working fine .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ted from Harrisonburg, VA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
icemaker stripper fall a part
instalation was very easy - but the part was 3/4 inch to long and a 1/32 inch to wide.Trimmed it with the "faithfull"
Dremel and it works!The instalation part of the "job" was less then 10 min.
Dremel and it works!The instalation part of the "job" was less then 10 min.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from Callaway, FL
- Parts Used:
- WR30X10093
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers, Wrench (Adjustable)
Ice maker arm disconnected from frame causing problems.
The icemaker arm disconnected from the metal frame. This caused the icemaker to cycle and the heater to come on and stay on until the plastic parts melted causing a mess and stink. This action melted the ice and then the water fell through the frozen items in the freezer and refreezed in the lower portion. OK, I remover the dead icemaker and tossed it away. I installed the new icemaker and the wiring harness didn't fit right (way to long). I retrieved the old icemaker and removed the wiring harness from it. I removerd the new ice maker and installed the old wiring harness to the new icemaker. I then installed the new icemaker, plugged it in and turned on the power. No water, I ordered the dual solenoid water valve, installed it with difficulty (another story) the turned on the power. I reinstalled the ice bin and found it didn't fit. The icemaker was to low and couldn't be adjusted, 1/4" higher would have been great. I shoved in the bin anyway, I was out of ice for my scotch, and it started making ice.
Was this instruction helpful to you?
Thank you for voting!