Customer:
James from Virginia Beach, VA
Parts Used:
WR17X11653
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Flapper was stuck open. Old and warped.
Replaced flapper
16 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ronnie from Scottsville, KY
Parts Used:
WR51X10101, WR50X10068
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
It would freeze up and then it would not cool.
First I unplugged the refrigerator, then I had to open up the back of the freezer, use the hair dryer to defrost the ice that had built up in it. Then I unscrewed the screws on both ends of the existing heater unplugged the old heater and plugged in the new one. Then with the sensor, I cut and stripped the 2 wires attached to the old sensor 1 inch away from the sensor. Then I spliced it with the wires on the new sensor, applied wire nut and black tape tightly. Then I put it all back together.
12 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marion from Palm Coast, FL
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Refridgerator Freezer stoped making ice
Turned off power, removed cover from Ice maker, checked resistance across thermostat for zero (read open), all other switches read proper value (when activated). Ordered and received thermostat. Removed Ice Maker from freezer, removed two screws holding ice tray to Control Assembly. Removed Thermostat and replaced with new one. Applied Silicone Sealant to face of Thermostat for adhesion to ice tray when assembled. Remounted Ice Tray to Control Assembly and remounted in freezer. Works Great...
17 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Laura from Manchester, NH
Parts Used:
WR02X11330
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
16 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Russ from Bella Vista, AR
Parts Used:
WR51X10101, WR50X10068, WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers, Screw drivers
Freezer would have ice blockage and eventually both sides would quit cooling. Starting with the refriidgerator side then the freezer side temp would eventually begin to rise all over the course of 2 to 3 days.
Unplugged the refrigerator and removed inside back panel from the freezer compartment and left doors open to allow all ice to thaw. I chose not to use a hair dryer and speed up the process as this could possibly cause more damage if not done with caution. After all ice was melted i took both screws from heat element assembly and followed the simple instructions that came with the new part. Since meters an i dont really work well together and since defrost thermostat and temp sensor were so inexpensive. I opted to purchase those as well in my initial order. They were as simple to replace as a lightbulb. Unscrew the wire nuts from existing sensors and screw wire nuts back on to the new sensors. Buy purchasing all three items at once i felt it just ensured the fiz was complete and the unit has been operating for 7 days like new. One thing i would pass on. If it is the heating element that is burned out, the glass tuve on mine was very black and charred looking. Also when you take it out of the assembly the element was actually in two pieces. Did something cause the element to stay on until it burned out or just old age i dont know. Again, for less than 20 bucks i purchased the additional parts that would seem most obvious to replace and i would recommebd the same. Part select saved us a lot of money not only in parts but in allowing someone with no considerable knowledge in this areato make repairs without hiring an expensive repairman.
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
roy from spring hill, KS
Parts Used:
WR02X10552
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
going from warm to to cold
i used the video it showed on the site or iwould not have been able to do it
16 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Auburn, AL
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice machine wasnt making ice
First I turned the refrigerator and water line off. Then moved to the freezer section, followed the directions, removed the two screws. Directions state to not remove them but I had to in this case. Unplugged the ice maker and removed it from the freezer. I installed the two mounting screws then tried to plug the electrical connection back in but had to use the adaptor cord furnished in the kit. The cord was a little long but I tucked it in and mounted the ice maker. Turned it on then turned the refrigerator and water back on and in a few hours had ice! Very easy to do!
14 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
xiaopeng from canton, MI
Parts Used:
WR51X10101
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
defrost heater burned out. Lots of ice in and ont he evaporator. Both breezer and refrigerator do not cool right.
Disconnected power. Removed evaporator cover in freezer. Removed the bad defrost heater. It is a glass tube about 10" long. The tube was black since the internal heater wire burned out. Use a hair dryer to melt ice in evaporator. Since there was excessive water coming from melt ice, I removed the back panel and took out the white plastic drain tube and collected water from the tube in a bucket. I put everything back and used the refrigerator for three days without problem, before the new heater arrived. Then I put on the new tube and everything was fine so far.
10 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ernest W. from Charlotte, NC
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Ice maker Stripper lost a tooth
First turn off the power, remove the ice tray, remove the two screws holding the ice maker to the side of the freezer, use the screw driver to gently open the electrical clip for the power cord inside the freezer, remove the complete unit from freezer, bend the old stripper from the holding pin- it is flexible- it will bend, replace the new stripper on the holding pin and bend into the slot to hold it firmly, no water will come out from the fill cup into the freezer, plug in the power cord, mount back to side of freezer, you are done.
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Columbia, CA
Parts Used:
WR11X10010
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Feezer door would not always seal
Because the lever was broken, when you close the refrigerator door, the freezer door would unseal slightly causing frost to build up on the inside and outside of the door.

After removing the base grille, the repair was made by simply placing the new part in the slot where the old part was then re-attaching the spring from the part to the hook in the base of the refrigerator. Now replace the base grille with the two screws. Time: About 10 minutes. Tools: Phillips screwdriver, needle nose pliers.
11 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
robert from bensalem, PA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
broken ice maker
removed 3 screws unplug and remove old unit. install two screws install new ice maker, tighten screws plug in and turn on. had ice in 20 min.
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David G from Walpole, MA
Parts Used:
WR17X11459
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
replacing ice maker drive dispensing cup
followed instructions already posted on your website, but had a very difficult time getting the dispensing side of the auger assembly to slide out, even after I disengaged the plastic tabs. There is no easy way or place to grab the assembly to pull it out. Finally turned the unit upside down and pounded on the edges of the assembly with a wood block and a small hammer. Once the part started coming out a couple of inches, I flipped over the ice bin and was able to pull it out the rest of the way, once I had something to grab on to. After the auger assembly was out the cup replacement was easy per posted instructions and the unit snapped back together easily.
11 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
mike from Aguilar, CO
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
refrigerator and freezer stopped working
I replaced the three sensors, 2 in the freezer 1 in the refrigerator. This was rated as the most common problem. Did not fix the problem. I then checked the ohms on the new sensors then the old sensors they were all within .5 of each other. So I got smart and went down the list of causes on their list. I emailed partselect and asked what the parts should read. They replied with that information and it turned out to be the voltage converter on the compressor. I ordered the part on friday payed for overnight delivery and it arrived tuesday. This as you can imagine makes me angry. But the part was easy to install and my refrigerator started working right away. I would advise anyone with this problem to start at the top of the problem list use a multi meter check everything on the list and only replace part or parts that don't come up to standards. This will save time and money and hopefully fix the problem the first time as you are not switching out parts and hoping that it solves the problem.
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Cape Canaveral, FL
Parts Used:
WR51X10101, WR50X10068
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
The Factory "Single" Defrost Element Was Burned Out.
Unplugged frig. Emptied freezer shelves of food, removed ice container, removed all shelves, removed light bulb cover and light bulb, removed rear panel over coils (2 phillips on bottom and 2 1/4" hex on top/staggered. Used hair dryer hung on a wire to defrost the "ice block" over the coils. Used heavy towels to catch the water in the bottom so the condensate drain didn't just overflow. Removed the 2 screws holding the old element. Unplugged the quick disconnects. The new 2 element heater purchased at partselect is not "encapsulated" like a florescent tube as was the original. Much greater efficiency with exposed element coils. Re-routed blue wire on left of coil bank to the right-used the same split insulator that pink wire is in to keep it safe, did not need to use the jumper extention that comes with the kit. Plugged in both the blue and pink wire quick disconnects, installed the new defrost element with the 2 screws. Cut the old thermostat right up against it's sensor pot. Stripped existing wires, used my own wire nuts to mate the new thermostat, wrapped tight with electrical tape, then tucked them up underneath. Snapped the new sensor on the evaporator line at original location. Replaced panel, plugged frig back in, turned control in frig side to 1, and it works like new now. No more freezer burn. Ice cubes better. Still, this design is poor and no more ge major appliances for me.
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
GEORGE from ELIOT, ME
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Will not make ice
Bing , Bang, Boom.
13 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!