HTS16HBMW General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- ronald from springfield, VT
- Parts Used:
- WR60X31522
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
noisy fan
removed cover over fan, four screws. removed two screws ,that holds fan in place,removed two more screws that holds fan in bracket,then reinstalled
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edwin from BELLINGHAM, WA
- Parts Used:
- WR22X10068
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
replace broken door dairy
a-ok. no problems
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Coto de Caza, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Interior Light did not go on due to faulty switch
I ordered two switches, replaced both with a knife in 10 minutes. Interior light works, thanks.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Anthony from COVINGTON, LA
- Parts Used:
- WR09X20002
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The unit cycles but does not achieve proper temperature
Remove power from the unit. With short length #2 Phillips loosen and remove the two(2) screws on the control panel located center top of the refrigeration area. Slide the control panel back about 1/2 inch and allow it to dangle from its wiring harness. Pinch the locking tab on the harness connector with one hand and use the other hand to separate the two sides. A little force is required. Remove the control panel from the refrigerator and shut the refrigerator door. Examine and note the routing of the temperature probe (Silver colored flexible wire) take a picture for later reference. Remove the old and replace with new unit. route temperature probe like the replaced unit. Reverse the steps and reinstall the control panel. It is a good idea to also purchase and replace the defrost timer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- joan from STERLING HTS, MI
- Parts Used:
- WR60X31522, WR60X46086
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set
Fan not working
Took out old put new in. Watched a u tube, no problems
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- LARRY. T from KNOXVILLE, TN
- Parts Used:
- WR60X31522, WR60X46086, WR02X12008
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
intermittent loud screeching,,humming sound
removed food from freezer section removed fan guard, partially remove ice maker, remove back panel, then fan assembly,disaasembled fan motor from brackets, fan from motor, grommet from bracket. assembled grommet in bracket, fan blade on motor, motor in bracket, fan assembly back in compartment, installed back panel,then ice maker, replaced fan guard and food. no more noise.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from RNCHO CORDOVA, CA
- Parts Used:
- WR07X26748
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Does not start , trips breaker
I pried the relay from compressor with small screwdriver, cut and replaced burnt wire going to relay,pushed new relay on compressor and wires unfortunately it did not fix the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mackenzie from Williston, ND
- Parts Used:
- WR09X20002
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Compressor would randomly not turn on. Fridge too warm sometimes.
Replace temperature control. That fixed it. Also, removed plastic bag obstructing air vent in freezer which added performance. Fridge works good now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Scott from NAPLES, FL
- Parts Used:
- WR24X10228
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Socket set
Replace the door gasket on the freezer door of my top-freezer refrigerator
Removed the door by removing the two screws holding it on. Do not try to do this repair with the door attached. Easily removed the old gasket. Getting the new one on the door was EXTREMELY difficult. I couldn't do it. After 90 minutes, I gave up and called my appliance repairman. When he arrived, he and I worked together to get the new gasket on the door. It took 2 sets of hands to do this. It still took us about 40 minutes. My repairman had a few choice words about the design of the system holding the gasket on the door. Ditto for me. So the cost of my repair was doubled because I had to pay the repairman to help me attach the new gasket. I should have just bought a new fridge.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Henry from DOUGLASVILLE, GA
- Parts Used:
- WR09X20002
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Fridge never cuts off.freeze everything inside of fridge.
To remove the temp sensor.2 Phillip head screws not remove the cover inside fridge .the temp control knob cover.removed that and unplugged switch.installed new switch.reinstalled cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eileen from Coto de Caza, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers
switchlight on my refrigerator was not working
I found instructions on the web about how to do this repair, so I ordered the part with confidence. But the instructions simply said "pull out the old switchlight". That was actually somewhat difficult as the clip on the side intended to hold the part in was stubborn. I eventually used a utility to slice off the clip. From that point, it was just a matter of plugging in the new switchlight , which was very simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Boyd from Blaine, WA
- Parts Used:
- WR09X20002
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Could not adjust temperature
Replaced temp controller
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from Ridgecrest, CA
- Parts Used:
- WR60X31522, WR02X12008, WR60X46086
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Freezer was not freezing food.
Inspected freezer because food was not freezing, getting cold, but not freezing. Noticed fan was not blowing air, but making a little motor noise, like it's trying to turn. Removed cover panel, and found the fan blade rubbing on the panel, fan shaft was worn out and very loose, wobley. That told me the fan needed to be replaced. Found part on the GE Partselect website and ordered the parts via the website order process. This was easy. The parts were shipped quickley and were at my front door the next day. Couldn't believe it. The actual process was very easy: Remove cover, remove bracket holding fan motor, remove and replace motor, re-assemble parts. About 20-25 minutes from start to finish. Freezer is working like it's suppose to.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Fred from FLUSHING, NY
- Parts Used:
- WR60X10168
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
The freezer just cool but could not freeze the water and the front of door is quite hot to touch.
First I observe that the compressor motor is running since the freezer is cooling. The purchase of the condenser fan is initiated and when the part arrive it is just easy to reinstall the replacement condenser fan.
The problem on the front of the freezer door remains hot to touch and the compressor runs for a while and stop. The freezer is cold but still could not freeze the water. Inspection of the condenser fan reveals that it is not running. The order for the condenser fan from PARTSELECT came in a few days. Cleaning of the condenser of lint was first done and the process of removing the defective fan is just easy so with the installation.
The refrigerator as of now is running in perfect condition!
The problem on the front of the freezer door remains hot to touch and the compressor runs for a while and stop. The freezer is cold but still could not freeze the water. Inspection of the condenser fan reveals that it is not running. The order for the condenser fan from PARTSELECT came in a few days. Cleaning of the condenser of lint was first done and the process of removing the defective fan is just easy so with the installation.
The refrigerator as of now is running in perfect condition!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from BERLIN, MD
- Parts Used:
- WR07X26748
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
refrigerator would not get cold
got on part select web site and found other customers that had same problem and on their site they had comments from them to fix problem. I then took off back panel on frig where compressor is by removing 6 screws and found the relay attached to the compressor then pressing down on holding spring removed 2 wire alligator clips and it was bad ordered one from part select put the new one on an frig was fixed. entire fix took about 30 minutes from isolating problem to fixing it. thank you part select
Was this instruction helpful to you?
Thank you for voting!