Light switch inside refrigerator wasn't working
First turned off power and removed top shelf.
Then I used a flathead to slowly pry the switch out by the two sides. You just anlge ita bit and it slideds out easily. Then I disconnected the wires from the old switch, connected the new one and installed the new switch by snapping it back into the cutout.
Then I used a flathead to slowly pry the switch out by the two sides. You just anlge ita bit and it slideds out easily. Then I disconnected the wires from the old switch, connected the new one and installed the new switch by snapping it back into the cutout.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marcus from SLC, UT
- Parts Used:
- WR60X10172
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
My fridge and freezer were not getting cold enough.
The Fridge and freezer were not very cold except for in the very back of the freezer (where the coils are). So I opened up the back of the freezer by first removing the dome light cover and removing all the visible screws. I then lifted up and pulled out the vent in the center of the back panel and removed the two remaining screws on the back panel. At that point I removed the back panel exposing the coils and fan. I saw that the fan was not spinning so I used a screw driver to manually turn the defrost timer found on the top of the inside of the fridge. Once I had turned the defrost timer once complete rotation, and the fan didn't turn on, I was pretty sure that it was the fan. I still wasn't sure that the fan was the only problem, but I couldnt see anything else that wasn't working properly. I decided to take a chance and order the fan motor (not the entire assembly. it is easy to replace the moter only leaving the original fan blades and housing). Once I got the part, I unplugged the old fan motor, put in the new fan motor, and pugged it in and it started spinning right away. I put everything back together the same way I took it apart and it has worked great ever since.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- GARY from PARRISH, FL
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Wrench set
Failed Icemaker
Shut off power to the refrige. Removed old icemaker, using large hammer. Installed new unit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from worthington, OH
- Parts Used:
- WR9X502
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
refrigerator would not defrost
Look were timer was located, in my refigerator is next to the dial to ajust the temperature. used a screwdriver to get panel off. replaced timer then used a straight screwdriver to advance timer to turn on compessor . monitor temperature . checked out.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Raymond from Concord Twp., OH
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set, Wrench (Adjustable)
water valve didn't shut off completly
The valve is not a direct replacement,seems they
are not available,had to bend mtg. brkt. so valve
would mount in same position and cut off screw
type pressure fitting so could slide discharge
tube into new type connection, no instructions
come with replacement valve,asked several
places for info wanted to be sure before cutting
off end of discharge tube. Now valve shuts off
but water still in base of refrigerator must be a
leak in inlet tube behind freezer compartment.
are not available,had to bend mtg. brkt. so valve
would mount in same position and cut off screw
type pressure fitting so could slide discharge
tube into new type connection, no instructions
come with replacement valve,asked several
places for info wanted to be sure before cutting
off end of discharge tube. Now valve shuts off
but water still in base of refrigerator must be a
leak in inlet tube behind freezer compartment.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jania from Novato, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from Glendale, AZ
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Replace ice maker
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- erik from cut bank, MT
- Parts Used:
- WR9X502, WR50X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
the freezer worked but the refrigerator did not cool. The freezer iced up and did not defrost.
Replaced the defrost timer . It plugged in under the cover for the lights and controls in the refrigerator area. Replaced the deforst thermosat, took the rear cover off (at the back of the freezer) , cut the two wires and relaced the thermosat using wire nuts. Total repair time 30 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tracy from Yuba City, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Stripper on the icemaker broke into pieces.
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tom from Bradenton, FL
- Parts Used:
- WR30X10154
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Ice bucket missing
I discovered the ice bucket missing from my rental unit at the beach. I was able to go online with my Blackberry, easily navigate your website using the model number to look up the part information , order it, and have it in place for the next renter.
Without access to a friendly user website, I would have faced considerable delay in getting this part.
Without access to a friendly user website, I would have faced considerable delay in getting this part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from Bellevue, WA
- Parts Used:
- WR57X10033
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench set
Ice maker did not work
I removed one screw to loosen the cardboard panel that covered the old valve and one screw to remove the valve assembly. I disconnected the two wiring connections and unscrewed the two water line connections. Replacement was really easy since the bracket was the same as the old valve. The down stream water connection was different for the new (push in) than the old (threaded) but I cut the old threaded connector off and figured out that the new push in connection was solid (directions would have really helped here) Reconnected the inlet tubing and electrical wires and replace the panel and it was done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cristina from Los Angeles, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
ice maker not making ice
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Terry from Simi Valley, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- debbie from chino hills, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
icemaker developed a leak and froze over
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Barry from Phoenix, AZ
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice maker ot making ice
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.