Noel from San Jose, CA
Parts Used:
WR57X33326
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers, Wrench (Adjustable)
Water continuously pours out of the icemaker
A week earlier, we had frozen water all over the freezer section which obviously dripped from the icemaker. We turn off the icemaker and cleaned the freezer. Upon turning the icemaker back on, water continuously pours out of the ice tray. This time, even turning off the icemaker does not stop the water from flowing through. I checked and cleaned the water valve, reinstalled it and it still does not work. I had to crimp the water line and even remove the water filter to make sure there will be no water leaks.

When I got the new water valve, installation was a snap as I have already removed the old one. After installing the new valve and putting back the filter, everything is back to normal.

Procedure for removing/replacing the water valve:
(1) Unplug the refrigerator and move it so that you have some working space in the back. If there is a mechanical valve in the water line, close it so that when the hoses are unplugged, there will be no spills. If there is no mechanical water valve, you can simply crimp the hose with a rubber band or a cable tie.
(2) Use an adjustable wrench or a screw driver to remove the screws on the bottom panel. My refrigerator has 4 big screws and 1 small one that is used to anchor the water hose.
(3) Pull the panel up slightly to remove it. The water valve is mounted with one screw at the bottom-left corner.
(4) Use a screwdriver to dismount the water valve.
(5) Unplug the electrical connections to the water valve. My refrigerator has one Brown and one Blue connector. Remember which plug goes to which connector.
(6) Place a towel under the water valve and use the adjustable wrench to remove the main hose connection.
(7) Next, remove the hoses that to into the water valve outlets. On my refrigerator, these hoses are of different sizes and have quick-disconnects. I simply have to press on the collar at end of the hose, pushing it towards the valve to release the hose, then pull on the hose.
(8) Prepare the new water valve by removing the plastic cover that protects the connector for the main water line.
(9) Connect the main water line to the new valve using the adjustable wrench.
(10) Connect the two hoses of different sizes to the valve. You only have to push them all the way into each valve and slightly tug on them to make sure they are locked in place.
(11) Re-connect the Brown and Blue electrical connectors to their original location.
(12) Mount the new water valve into the back of the refrigerator (one screw).
(13) If possible, quickly check that the new valve is working properly: If you have a mechanical valve in the water line, open it and make sure there are no leaks near the valve or inside in the icemaker. You may have to plug in the refrigerator power to complete the initial test.
(14) Replace the back panel with the 4 screws and anchor the hose to the back with 1 screw.
(15) Once everything is back in its place and the refrigerator is on, cycle the water dispenser several times to run fresh water into the hoses and the new valve.
72 of 78 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from American Fork, UT
Parts Used:
WR50X10068, WR55X10025, WR51X10055
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Wrench (Adjustable)
Freezer compartment would freeze sold so the fridge would go warm.
Emptied the fridge and freezer. Unplugged it and in so do doing defrosted the freezer coils. Replace the listed parts, for they were right there easy to get at and replace. Between the three of them we had an 80% chance of getting what was wrong. The freezer and the refridgerator are both working just fine. No more warm milk.
77 of 93 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dan from West Bloomfield, MI
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Ice maker stopped working
I unplugged the electrical connection. Then I removed the 2 screws holding the icemaker in place. I lifted out the old icemaker unit and put the new one in place. Then put the 2 screws back in and plugged in the new unit.

The icemaker started making ice very soon after turning the unit on.
83 of 112 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Laura Beth from Mandeville, LA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
broken ice maker part
used a screwdriver to remove screw and unplugged part. Plugged in new one and secured with a screw.
Simple
78 of 104 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from North Salt Lake, UT
Parts Used:
WR17X22070, WR57X33326
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Getting ice but not water from the dispenser
On the web site I explained the problem and the solution was immediate. I went to the installation video and was instructed how to install the double outlet valve. It took about 10 minutes to take out the old part and install the new one. I didn't have water immediately so I viewed comments by others and learned that I may have a frozen line in the door. I tried thawing out the line and in about 3 hours and I had water. I figure I saved about $200.00 by doing it myself. Thank you partselect.com
75 of 98 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gene from The Woodlands, TX
Parts Used:
WR50X10068, WR17X11843, WR17X11446, WR55X10025, WR32X10200, WR02X10668, WR02X10647
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
not cooling, water in refrigerator
For several years, had problem with water accumulating in the bottom of the refrigerator...took out the "custom cool" drawer and assigned my kids the responsibility to dry it out daily after supper (about a fourth of cup of water daily)...the water was condensing and dripping down the left side of the refrigerator... NOT coming from the refregerator evaporator drip pan area. Then the refrigerator and freeezer had erratic cooling...paid 4 grand for this GE stainless steel on the front/sides frig about 5 years ago... then my wife said she wanted a new refrigerator...what the heck...went on to numerous websites and finally decided to do my own "overall"...had nothing to lose except the price of the parts. A helpful web site is the GE technician site at...www.manualinstruction.com/wp-content/uploads/2011/10/ge-sidebyside.pdf. I ordered the four thermisters, a new freezer defroster (the old one was probably OK...the freezer coils were not "iced Up"), and a new defroster thermonmeter. While I was at it, I ordered a new refrigerator evaporator drip pan that was rusting a bit. As per other instructions in this website, just spliced in the new thermisters,used wire twist caps and eletrical tape to seal them. The GE site is a bit more elaborate on the "correct" way to do this. The refrigerator evaporator coil is a bit tricky...see the above ge site...but I just cut the rubber thermister holder down the middle and then tracked the thermister through the holder and stuck it in the block and taped the holder back together...(removed the block first ) and then zip-lined the block back to the coil like it was originally. It was about 3 hours to do everything...and guess what...temp in the freezer is -5...temp in the frig is 36...and NO MORE WATER IN THE BOTTOM OF THE REFRIGERATOR, NO MORE WATER DRIPPING DOWN THE LEFT SIDE OF THE REFRIGERATOR...what will my kids do...I feel like the refrigerator guru now. Wish I had done this several years ago. The parts I ordered came in 3 days. I'm lovin my refrigerator now and my wife is lovin me. It's really easier than I thought it would be...the GE tech website has some "diagnostic" info to isolate different problems... but I just decided to replace "everything" since the parts were not that expensive and it was going to be a "do or die" on getting a new refrigerator.
67 of 78 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ray from Bensalem, PA
Parts Used:
WR60X10209
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
fan not running
Removed rear and front grills,brushed and vacuumed area- probably caused the fan motor to fail- unplugged fan, removed fan,motor,and shroud in 1 piece, carefully slipped fan off motor shaft, unscrewed shroud and motor. assembled in reverse order. Frige is in tight area, .I'll now roll it out and clean often
74 of 104 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Turcotte's Housing Service, In from Newmarket, NH
Parts Used:
WR62X10055, WR17X11653, WR2X8818, WR17X10706, WR02X10585
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Recessed door on ice dispenser would stay open causing the freezer to frost up
I inserted the tip of a very small screwdriver from a eye glass repair kit into the three small holes under the panel near where the ice is dispensed. I never would have known about this simple procedure if it wasn't for the feedback you post from your parts cumtomers. Once I did this the front panel with the buttons on it poped off and it was just a matter of removing a few screws at that point. The wires from the new solenoid easily plugged into the board on the front panel. I would recommend changing the screws at the same time. The old one's worked but they were rusty. I feel the solenoid was my only problem but I changed all the parts in between the dispenser door and the solenoid just to be sure.
70 of 92 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Romeo, MI
Parts Used:
WR60X10185
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
The evaporator fan motor stopped running, freezer was warmer than normal
First ,I placed all the frozen food from the freezer into the lower fridge compartment. Removed the main shelf. Removed the ice cube tray shelf. Removed the center plastic covers using a nut driver. Removed the complete inside back wall of the freezer to get access to the fan. Simply removed about 5 screws, and cut 3 tie straps that held the wiring in place. Unplugged the fan connector and removed fan with its brackets and placed them on the kitchen table. Then used the nut driver to remove 2 screws which hald the fan to its bracket. Simply pulled off the fan blades and pressed them onto the new motor. Mounted new motor onto the bracket. Reinstalled the fan assembly back into freezer. Reconnected the wiring and the fan began to run... BE CAREFUL NOT TO TOUCH THE FAN WITH YOUR FINGERS!
Finally replaced all the covers, panels, and shelf etc. and everything is once again nice and cold.
66 of 88 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lorinda from Dallas, TX
Parts Used:
WR23X31507
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
dropped something on the light switch and it broke off
we just pried out the old switch and pulled it out the rest of the way with a pair of needle nose pliers. Pulled off the wires on the broken switch and reattached to the new one and just slid/clicked it back into the hole.
59 of 68 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Terrence from Escalon, CA
Parts Used:
WR50X10068, WR55X10025
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Ice maker failure due to chunks of ice building up in tray
My problem began with having to replace the auger due to damage (broken blade). Unknown at that time the unit was having a defrost cycle issue. Once auger was repaired, then the motor to auger failed. Once repaired the GE unit then began shutting down without warning. Mother board replaced. All was fine for two weeks then noticed odd performance by ice-maker (chunks of Ice again)and frozen package containers showing signs of dampness and then refreezing. Read through the Parts Select web site to see what other users may have had gone wrong with their GE's and what the parts overview section may reveal for me. Found that the defrost thermo and temp-sensor controlled defrost functions. The parts were cheap, $20.00 for the pair so I replaced them both since they are both located next to one another in the freezer compartment. The repair video furnished on the P/S web was great and very accurate. The entire job only took about an hour. The repair video indicated using wire-nuts and electircal tape Instead, I chose to solder the wires and use shrink-tubing to provide the moisture barrier. PartSelect folks are great not only for their parts pricing but also for the informative videos. The GE works better than ever
63 of 84 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
randy from vancouver, WA
Parts Used:
WR02X11330, WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers, Wrench set
Water Leaking @ Quick Releases (Blue and White)
Had previously replace the plastic Water Tank, but when installing it I didn't realize how the quick connects worked. Instead of simply pushing inward in the direction of the blue part of the disconnect, I had pulled out the white ring on the outside of the disconnects. This ruined the inside connections and caused them to leak thus requiring these repairs. Had I known that I wouldnt have bought these parts too. Just Always REMEMBER to push in outside white ring on the quick disconnect and as you push it in pull out the hose when you remove it. To put the hose back in, just push it back in without pushing on ring this time at all and it will lock in place, and shouldn't be leaking. I had to run water into a glass to test if it was leaking, otherwise the line had no water pressure.
57 of 70 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bill from Corona Del Mar, CA
Parts Used:
WR17X11459, WR17X11458
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
ice dispenser would not turn
It appeared that the helix lock wore out first, then the cutter teeth dug into the side of the plastic housing. Then the cup drive broke in half from the helix being jammed. Removed the ice bin from the refrigerator. removed 4 screws around the edge of the bin. Pry open clips that hold the auger assembly in place. Remove the clip from the end of the auger. Pry old plate helix lock from holder. Pull out helix auger removing cutters and keeping everything in order. Replace old plate helix lock with new one. Replace cutters in order and tighten nut and install clip. Put new cup drive on end of helix. Snap assembly back together. Replace screws.
61 of 83 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Gainesville, VA
Parts Used:
WR60X30922, WR60X10185
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Fan motor making noise due to broken fan blade
1) Unplugged fridge and removed cover over light in freezer.
2)Removed screws holding cover over motor.
3) Removed screws on bracket holding motor in place.
4) Un plugged motor and used razor blade to cut grommet holding wires in place.
5) Plugged in new motor and routed wires through grommet. Then used zip ties to hold grommet together.
5) Re-attached motor bracket and installed new fan.
6) Reinstalled cover over motor.
64 of 93 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jon from Fenton, MO
Parts Used:
WR60X30922, WR60X10185, WR02X12008
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Socket set
Refrigerator fan was very noisy and we started to notice frost on our food in the freezer.
I should state first that I am a DIYer and have no experience fixing appliances. The fan noise seems to be a common problem. It has something to do with the bearings. Mine was actually hitting the housing in front on the fan as well. Getting into the installation, I knew I had to take the back panel and fan housing off. But I found out that everything needs to come off. This is the ice maker, the housing underneath the ice maker as well as the fan housing and back panel. This isn't difficult but good to know before hand. A quick note, the light bulb housings come out by pulling them forward. It's a good idea to label the screws as you take them out as there are quite a few that need to come out. I replaced the evaporator fan the fan blade and one grommet. In hind sight I should have replaced both grommets as they both showed wear. They are both exactly the same so you can order two of the above. All in all this is a pretty easy fix. It takes a bit of time, but it's not to difficult. Th most difficult thing was the wiring. The fan comes with a six prong connector and has four prongs taken up. There is, what I think is a temperature sensor, that takes up the other two prongs. Since I didn't order that part, I had to cut it out of the old connector and insert it into the new evaporator fan connector. This was a bit difficult and would have been much easier if I had ordered the part. Unfortunately, I don't know what that part is called, but it must be some kind of temperature sensor as it clips on the coil. The wires also run through a blue rubber wire-run that needs to be sliced open. This was pretty easy to do with a small serrated pocket knife. SLice it on the back side of it and pull the old wires out. When you are ready to install, just run the new wires through the hole from the old wires. Once you have replaced the fan the new blade and the two new grommets, it's just a matter of replacing all the equipment. Fan housing first, then the upper housing followed by the ice maker and the back panel. Good luck