- Customer:
- JANUIR from Woburn, MA
- Parts Used:
- WR60X10220, WR60X10207
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
the refrigerator did warm up arround the doors until the freezer side stops work.
After I have checked oline , I ordered the parts wich Igot a day early and fix it , it took me about 15 minutes and I saved at 250.00 dollars . Thanks for all the help.
J Serpa ,Ma.
J Serpa ,Ma.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from ROSEMOUNT, MN
- Parts Used:
- WR55X10025
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of freezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tom from KALISPELL, MT
- Parts Used:
- WR60X10220
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Socket set
Fan Motor Was squeaking and not running up to par
I watched the repair video on partselect's website for the condenser fan motor and realized I could do the repair. The hard part was putting the two screws back on the bracket to mount the fan. (they were not easy to get to with your hands let alone tools) other than that super easy and great experience!
Tom
Tom
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Glenn from Nash, OK
- Parts Used:
- WR60X10220
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Fan motor making noise, compressor overheating
Simply followed the video -- VERY helpful... BUT: getting the bottom tab to re-insert into the holder after the motor was replaced was VERY difficult...!!! Until I discovered that I could move the refrigerant coil (upon which the tab mounts) just enough that I could get the tab inserted...!!! "Twas NOT as simple as it looked on the film...
Being able to move both the fan motor holder (with the tab) AND the coil made it happen, easily...
Being able to move both the fan motor holder (with the tab) AND the coil made it happen, easily...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carlos from Copper Canyon, OK
- Parts Used:
- WR09X10107
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Start relay burned
Unplug the refrigerator removed the condenser/ compressor cover back bottom on fridge, remove the relay from the compressor took off the two wires, replace with new relay
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Craig from CYPRESS, TX
- Parts Used:
- WR60X10220
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
The frig overheated between the freezer and the frig. The fan did not start.
I replaced the compressor fan.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from El Dorado, AR
- Parts Used:
- WR60X10185
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Bottom of refrigerator wouldn't coool
I removed the top vent and unplugged the ice machine ,took the back cover off the freezer.Removed the old fan which was pretty easy(unplugged it after I took the housing out for easy access) I plugged the new fan in and put everything back in the order I took off, and yada yada yada we have cooling.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christopher from NAZARETH, PA
- Parts Used:
- WR60X10220
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
The panel between the refrigerator and freezer was very hot. This was cause by inadequate airflow over the condenser coils.
Unplug the unit and pull away from wall. Remove the screws from the lower back panel. Locate the condenser fan motor and the bracket holding it in place. Unplug the wire clamp connecting the motor to the power supply. Remove the screw holding the bracket onto the condenser coil. Pull the entire assembly from the unit. Pull the fan off the old motor. Remove the motor bracket from the larger bracket. Replace the motor. Assemble again with the rubber grommets, motor bracket, and fan. Reinstall larger bracket, now with new motor, into the unit. Ensure the bracket prong is received into the coil bracket. If all aligns well, screw the bracket back onto the coil. Plug the new motor into the power supply. Temporarily plug in refrigerator to confirm motor functions. Unplug again and replace lower panel.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from KNOXVILLE, TN
- Parts Used:
- WR60X30922
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice built up around evaporator fan blades and blades chipped and broke. Refrigerator was making loud vibrating noises.
Removed ice bucket, and unplugged ice maker. Removed light cover. Removed ice maker. Pulled fan blades straight up and removed. Pushed new blades on to motor shaft. Fairly easy .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- TIMOTHY from ROBERTSDALE, AL
- Parts Used:
- WR60X10220
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Frig stopped cooling compressor was very hot fan was not turning.
Remove back cover on frig, unplug wire on fan motor, remove one 1/4 screw from top right corner of fan cage, fan cage will come out with a little twist, take note of tabs on fan cage for reinstall, remove two more 1/4 screws, take care to watch where rubber bushings are located on motor and ground wire location, fan blade will pull off of fan shalft easily, install in reverse. Very simple fix.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Vickie from BISMARCK, MO
- Parts Used:
- WR13X10285
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
was no problem an easy fix
just screwed it on
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dan from COLUMBIA, SC
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
Refrigerator not getting cold
Replaced Temperature Sensor and now it is getting cold.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wayne from MARICOPA, AZ
- Parts Used:
- WR60X10220
- Difficulty Level:
- Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Socket set
Replace Condenser Fan Motor
Attempted to remove whole bracket per PartSelect YouTube video. Our refrig must have been slightly older or something, because the bracket would not come out no matter how much we begged and pleaded. ~ So we replaced motor in place, which was a headache, but doable. Seems to work fine, and much quieter than the old motor.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from BURNEY, CA
- Parts Used:
- WR02X11331
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Socket set
Loud Squeal when fan was running
WE (WIFE) took out the old parts an replaced with new one ..Be careful to get the placement of the Grommet or they "POP" out on you. fast ship on the parts too.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from PARKVILLE, MO
- Parts Used:
- WR02X10098
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Had a 'ticking' sound
Separately (from a different site) purchased new compressor fan and motor. I purchased the grommets here because the other site listed the grommets as temporarily out of stock. I did watch one of the videos on PartSelect about the grommet replacement. Repair was pretty simple, biggest challenge was getting to the screw on the far side of the motor. Removed the two screws holding the fan motor into place. Removed motor and blade. Reinstalled with new fan blade, new grommet and new motor.
Was this instruction helpful to you?
Thank you for voting!