- Customer:
- Charles from Keller, TX
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Maker would not fill.
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.
Went ahead and installed the unit, using the supplied electric cable adapter.
A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Went ahead and installed the unit, using the supplied electric cable adapter.
A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bob J from Platte City, MO
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Water not dispensing
Background: My refrigerator was part of the class action law suit back in 2006. As a result both doors, the auger in the ice maker and a heating element in the freezer were all replaced.
Problem this time: Water was not dispensing.
Solution: Replaced the double outlet water valve in the back lower left portion of the refergerator. Water was coming into it from the water filter hose, but not coming out of it when the water dispenser in the front was engaged.
Further, I found that the coils in the back of the freezer were iced up and I therefore defrosted them with a heater. Thus, the original problem encountered with the law suit, did not get fixed by simply replacing the doors. That problem is still there. I think the defroster/heating element in the freezer is again not working.
However, I do now have water flowing again and the installation was, as others have described, very easy. Thanks for the online help.
Problem this time: Water was not dispensing.
Solution: Replaced the double outlet water valve in the back lower left portion of the refergerator. Water was coming into it from the water filter hose, but not coming out of it when the water dispenser in the front was engaged.
Further, I found that the coils in the back of the freezer were iced up and I therefore defrosted them with a heater. Thus, the original problem encountered with the law suit, did not get fixed by simply replacing the doors. That problem is still there. I think the defroster/heating element in the freezer is again not working.
However, I do now have water flowing again and the installation was, as others have described, very easy. Thanks for the online help.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Albuquerque, NM
- Parts Used:
- WR72X239
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
slide rail broke causing shelf to fall
repair was simple removed glass shelf and removed the two screws holding rail in place. I was really amazed at the quick service that I had receiced, I ordered two of the same part and they had the instructions to send back the additional part in my email the next day. Thanks for your help.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Sylva, NC
- Parts Used:
- WR50X10068
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Ice cubes froze in the tray and frost was all underneath
I read stories from the website how others did it so I figured I would give it a try. I put all the frozen stuff in the refrigerator piled up. Took out the shelves. Took out 2 screws with a socket extension ( nut driver will work fine.) Remove the light bulb. lifted up on the back panel...it came right out. Saw the coils and on top the sensor. Took it off, cut the wires, spliced in the color coded new one ( pink to pink, orange to orange) Stuck it in the top coil in the original position and crossed my fingers! I put all the pieces back easily, restocked the freezer and waited. HOORAY!! My ice cubes are all separate and free. NO frost inside. A very easy fix for $20.
Note: If there is a large amount of ice build up on your coils a hair dryer works great. The drain is on the bottom anyway. Also , you may want to seal around the wire nuts to keep moisture out. I did
Note: If there is a large amount of ice build up on your coils a hair dryer works great. The drain is on the bottom anyway. Also , you may want to seal around the wire nuts to keep moisture out. I did
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from Pickens, MS
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Ice maker was over filling and freezing the cubes together.
I turned water off at valve and unplugged refrigerator. I removed screws to remove cardboard cover at bottom. I removed screw holding duel inlet water valve bracket and pulled out valve. Then it's just a matter of exchanging electrical connections and water lines. The electrical connections unplug and plug in-red to red and blue to blue. The water lines are two different sizes so they can't be mixed up. Then reattach bracket and cardboard cover. Turn water back on and plug back in.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alex from Tampa, FL
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Water not dispensing
Moved refrigerator forward, this allowed me to work on the back panel. Unplugged the refrigerator power cord. Released all 6 screws, removed panel then release an additional screw that was holding the water valve and the two (red & blue) connectors. Then installed the new part in reverse steps. Plug the unit and job well done. I had purchase the water filter already after several minutes push for water from the dispensing front part of the refrigerator and good to go, later in the evening we notice the ice maker working fine and producing ice. Thank you parts select.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dean from Folsom, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The Icemaker failed to make ice
I pulled the refrigerator away from the wall and turned off the water to the refrigerator and unplugged it from the wall. After removing the icebucket from the freezer I located the mounting screws, loosened them, unplugged the electrical connection below the icemaker and carefully removed it from the freezer. I unpacked the replacement icemaker, matched it against the original and attached the electrical connection adapter. Using the slots provided on the new icemaker I placed it over the mounting screws after aligning the water inlet pipe properly. I tightened the mounting screws while maintaining the icemaker in a level position. I plugged in the electrical connector. Then I replaced the icebucket, plugged in the refigerator back into the 110VAC outlet, turned on the water and repositioned the refrigerator in it's normal position.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- david from manassas, VA
- Parts Used:
- WR72X241, WR71X38317
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
broken parts
went good everone at partssel was great
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lanis from CUMMING, GA
- Parts Used:
- MWFP, WR71X10232
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Refrigerator shelf was broken and the water flow was a dribble.
Removed the taped together broken shelf and replaced with the new replacement shelf. Following the online instructions, the old water filter was removed and the new water filter was installed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from FARMINGVILLE, NY
- Parts Used:
- WR60X10185
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
refrigerator not cold
removed freezer door / shelf /ice maker pulled back panel off and removed fan
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- kay from clermont, FL
- Parts Used:
- WR71X10232
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
broken shelf
replace shelf
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Longwood, FL
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
No water dispensed from door tap, icemaker OK
The problem was both the valve and a frozen slug of water in the supply line located inside the door. After replacing the valve, I turned the freezer to a setting of 1 and in about 30 hours, water flowed out the tap.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from San Marcos, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
no ice made
Performed self test.turned off ice maker switch four 5 minutes.Then turn on switch,within 10 seconds,pushed ice paddle 3 times,with 1 second in between each push.Push all the way back and release. Ice maker should cycle and squirt water. My ice maker did neither.I unplugged cord from fridge.So i replaced the ice maker.After a couple of screws had ice again !
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Federal Way, AL
- Parts Used:
- WR23X37285
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Difficulty in removing the old switch
The old switch was hard to remove. Thinking that I may have to loosen the wires I used a socket wrench to remove a clamp. This was unnecessary. In the end the switch did come out using a large size screwdriver. The problem was that the expanding plastic tongue is not visible from the ouside so you have to try to feel your way around. If i had ordered the replacement before and not afterwards I would have seen this before hand.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from St George, UT
- Parts Used:
- WR51X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator temp went to 60 degrees
Freezer section defroster heater was inoperative.
turned off the refrigerator by turning the right knob in top rear refrigerator to 0.
Used hose on a vacuum sweeper blower side to feed warm air into the bottom rear section. Removed the top plastic panel behind the ice maker to allow air flow to exit through the fan to defrost the freezer coils.
Placed a flat oven pan into the area beside the vacuum hose and sponged up the melted frost water. After 30 minutes, water ceased to drain.
Removed freezer shelves, and 5 screws on rear freezer wall. It took about 2 minutes to remove the heater & braw assembly at the bottom of the coils. 2 screws have to be removed and wires just clip off and back on again. Replaced the 2 screws.
Replace rear coil wall cover and turn on the refrigerator to 5 to 7 and replace cover and shelves.
turned off the refrigerator by turning the right knob in top rear refrigerator to 0.
Used hose on a vacuum sweeper blower side to feed warm air into the bottom rear section. Removed the top plastic panel behind the ice maker to allow air flow to exit through the fan to defrost the freezer coils.
Placed a flat oven pan into the area beside the vacuum hose and sponged up the melted frost water. After 30 minutes, water ceased to drain.
Removed freezer shelves, and 5 screws on rear freezer wall. It took about 2 minutes to remove the heater & braw assembly at the bottom of the coils. 2 screws have to be removed and wires just clip off and back on again. Replaced the 2 screws.
Replace rear coil wall cover and turn on the refrigerator to 5 to 7 and replace cover and shelves.
Was this instruction helpful to you?
Thank you for voting!