Jason` from Colchester, CT
Parts Used:
WR60X10185
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
freezer fan failing; veried speed making whirling sounds
First, I removed all the shelves and the light guard. Second, I removed the nuts that held the fan guard and the freezer back in place (2 just under the fan guard and removed the freezer back. Third, lifted fan guard out of way (being very careful not to crack it..... cold plastic). Fourth, unpugged fan from pug then removed nuts that held fan bracket in place...removed fan. fifth, then removed fan blade and remove fan motor from bracket, removed two wires that went to freezer light (pay attention to where they go) and installed them into the new wireing harness. Sixth, installed fan blade on new motor, bolted new assembly in fan bracket, plugged in and reistalled fan into the freezer, replaced fan guard and freezer back (reverse order of above) and then replaced freezer racks. works beautiful.
14 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Hanford, CA
Parts Used:
WR01X10315
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Ice Maker auger blade broken
The ice machine auger blade broke a chunk off. I decided to try to replace it myself. I bought the new auger blade and then sat there and stared at it and the ice machine for a few, trying to figure out how to change out the part. Turns out it was a qute lengthy process. The auger is threaded on one end and the ice chopping blades are on it. So I had to take each blade off the old one and put it on the new one. The blades have to be positioned just right on the shaft so it's best to just draw a line down over all the blades so as to put them on the new auger successfully. The problem I had was the end cap that screwed on the end of the shaft. It was the part I ordered here. It is made of plastic with plastic threads and at first I couldn't figure out to get it off. Turns out the threads are opposite normal. By the time I figured that out, I had just about destroyed the cap using pliers to try to unscrew it. There is a washer and half moon clip that fastens on this end nut so if you mess the nut up, chances are you won't be able to get the half moon clip to go back on. I finally did it right and now how the ice maker working right again. A hard part for me was figuring out how to set the spring shaft that works a lever to either give cubed ice or crushed. I had to keep fiddle with it before I finally got that right. At first I was only getting crushed ice even with the cubed setting and then only getting cubed ice with the crushed ice setting. After some fiddling, I got both to work but to this day can't figure out what changes from the crushed setting to the cubed setting.
18 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steve from DOWS, IA
Parts Used:
WR51X10055
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Freezer Cold Refrigerator warm
The defrost heater failed. The coils frosted completely over so no airflow to the fridge. Step 1. Empty the freezer. Ice maker and top shelf can stay. Remove power, pull plug or open breaker. Step 2. Remove shelves and bottom food drawer. Step 3. Remove bottom food drawer rails. 2 phillips screws on each side. Step 4. Remove back panel, 2 screws at the top. Work panel out. Note there may be a green ground wire hook on it at the top. This will expose the heater and the cooling coils. The heater is at the bottom of the cooling coils and is the width of the coils. Step 5. There will be 2 wires, one on each end, and two phillips screws holding it in. Wires pull straight out. Note which way the heater is installed and remove the 2 screws. Step 6. Assemble in reverse order. Be very careful with the heater. It is in a glass tube and is very easy to break.
13 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
calvin from annapolis, MD
Parts Used:
WR62X10055, WR17X11653, WR17X10706, WR02X10585
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers
when dispensing ice the flap door would not open properly and was open most of the time causing the door to ice up...cause solenoid was rusted badly
I removed the screws for the inner door and removed inner lining. Then took out the ice dispenser in the door. Took off control panel on the front of the ice panel. Removed the rusted parts and put in new parts. Put all parts back the way it came apart. In retrospect.... I could have possibly replaced the parts from the front panel but by taking apart the door...I had to thaw out the inner panel and insulation with in the door.
19 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
lk from carlsbad, CA
Parts Used:
WR60X10185
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Loud knocking noise with the evaporator fan
I had taken the noise long enough and wanted to get this repaired. I didn't want to pay a repair man hundreds of dollars to do it so i decided to do it myself. I went on to YouTube and found a few videos that showed me how easy it was to do (very helpful).

I wasn't so sure all that noise would come from the Evaporator Fan motor so i ordered it and took the chance. For the small cost, it was worth the try.

All went well accessing the unit and removing the old part. Very fast indeed. However, the snag came when i went to plug in the new part electrical to the existing electrical adapters. The old part had 4 lead connections. The new part had 6. and the wires on the new part were different colors than the existing. I had to use some logic and courage to cut the wires on the new part and rewire the old adapter to this piece. Luckily, i wired everything correctly.

Calling Part Select got me a phone number for the parts manufacturer to help with the splicing but i opted to do it on my own.

The result is i have a noiseless refrigerator again. What should have taken 10 to 15 minutes took half an hour because of the wiring but overall, very easy.
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Vallejo, CA
Parts Used:
WR23X31507
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Internal light switch was sticking
Two tabs hold the switch in place. I used a plastic wedge to remove the switch. Removed and replaced the two connectors held in by friction. Painless.
13 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Leo from TWIN FALLS, ID
Parts Used:
40A15
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Interior light needed replaced
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
22 of 43 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Goshen, KY
Parts Used:
WR23X21444
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Broken freezer light switch
Part arrived very fast as ordered..need to pry old switch out from top..use care to push the retainer down..after old switch was 1/2 out, I used a putty knife for better leveridge.Remove wire connector...after plugging in the wire connector to the replacement switch, make sure the switch is properly positioned so the switch will depress when door shuts.
14 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
ron from hermitage, TN
Parts Used:
WR23X31507
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Broken Switch
Just pop the old one out, careful not to lose the wiring inside the ref wall & popped the new one in.
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Virginia Beach, VA
Parts Used:
WR17X11653
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Flapper was stuck open. Old and warped.
Replaced flapper
16 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Florence, OR
Parts Used:
WR55X10956
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Overflowing ice maker creating glacier on back wall
No instructions came with the replacement control board. A notice that this part supercedes the original circuit board part number would have been helpful, although it is noted on the web site IF you drill into the parts list deep enough. Diagrams on the web site gave a general location for the circuit board.

Swap-out of the boards was relatively easy, although some of the connectors were reluctant to separate.

The new control board solved the overflowing ice maker issue.
14 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
roy from spring hill, KS
Parts Used:
WR02X10552
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
going from warm to to cold
i used the video it showed on the site or iwould not have been able to do it
16 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
mike from Aguilar, CO
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
refrigerator and freezer stopped working
I replaced the three sensors, 2 in the freezer 1 in the refrigerator. This was rated as the most common problem. Did not fix the problem. I then checked the ohms on the new sensors then the old sensors they were all within .5 of each other. So I got smart and went down the list of causes on their list. I emailed partselect and asked what the parts should read. They replied with that information and it turned out to be the voltage converter on the compressor. I ordered the part on friday payed for overnight delivery and it arrived tuesday. This as you can imagine makes me angry. But the part was easy to install and my refrigerator started working right away. I would advise anyone with this problem to start at the top of the problem list use a multi meter check everything on the list and only replace part or parts that don't come up to standards. This will save time and money and hopefully fix the problem the first time as you are not switching out parts and hoping that it solves the problem.
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David G from Walpole, MA
Parts Used:
WR17X11459
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
replacing ice maker drive dispensing cup
followed instructions already posted on your website, but had a very difficult time getting the dispensing side of the auger assembly to slide out, even after I disengaged the plastic tabs. There is no easy way or place to grab the assembly to pull it out. Finally turned the unit upside down and pounded on the edges of the assembly with a wood block and a small hammer. Once the part started coming out a couple of inches, I flipped over the ice bin and was able to pull it out the rest of the way, once I had something to grab on to. After the auger assembly was out the cup replacement was easy per posted instructions and the unit snapped back together easily.
11 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Don from Herndon, VA
Parts Used:
WR55X10956
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Ice would melt intermittently creating an ice wall on the back or side of the freezer.
Replacement of the Main Control board was relatively easy, although some of the connectors were reluctant to separate.

The new control board appears to have solved the problem.
12 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!