PSI23NCRCBV General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- David from White Pine, TN
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Would not cool top or bottom
Everything looked to be working but the compressor. As a pro checked every thing came down to a relay on the main board.
Just removed cover from back top left. marked and removed all wires. removed old board and installed new board very easy. Must read paper sent with it,
you may need to cut wires on some models.
Just removed cover from back top left. marked and removed all wires. removed old board and installed new board very easy. Must read paper sent with it,
you may need to cut wires on some models.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Keller, TX
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Maker would not fill.
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.
Went ahead and installed the unit, using the supplied electric cable adapter.
A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Went ahead and installed the unit, using the supplied electric cable adapter.
A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- nancy from Mt. Washington, KY
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench set
Was not getting water to the door.
Moved refrigerator out from wall, unplugged from electric, removed plate at bottom back with 1/4 nut driver, turned incoming water valve off, disconnected water line from water valve on refrigerator, removed mounting screw, remove water lines from valve and electrical plugs, set old valve aside and replace with new valve, reconnecting water lines and electrical plugs then remount bracket, reconnect water line from source, open water valve and check for leaks, replugged refrigerator and depressed the door button to check to see if working. It worked and there was not any leaks. Replaced back plate and placed refrigerator against wall. Job completed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeanne from Milledgeville, GA
- Parts Used:
- WR71X10764, WR12X10625
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Items were broken
Really easy to install - they both snapped into place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Frances from Beavercreek, OH
- Parts Used:
- WR23X31507
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Refrigerator light not coming on
Our daughter spilled juice on the refrigerator light button. It started with the light coming on very slowly and then not at all. We popped off the old button with a flat head screwdriver, plugged in the new one. Works perfect. Can't believe how inexpensive and easy the fix was.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- louis from floral park, NY
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
evap fan not working.
first i removed the three screws that covered the circuit board that was bad. then i removed the 6 connectors that went from the refrigerator to the board then popped out the old board , popped in the new board reconnected the circuit connectors covered everything back up and my refrigerator is back on line. this all took about 10 to 15 minutes time ... thank you for your product it really did the job..
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Summer feild, FL
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
cold water dispenser would not stop running
Turn off the water.
Unplug the refrigerator
Take the back off of the refrigerator
use socket wrenchs to undo and take off the water valve in the lower left corner of refrigerator.
Pull out and disconnect electrical connections
Pull out the 2 water tubes one for ice and 1 for water-white is water and black is ice.
install the new valve and connect the water and ice back in the new unit
connect the two power cords and reattach unit to the frame Turn water on and check for leaks.
If no leaks put back on refrigerator and plug in.
Wait 30 min to an hour for water to begin to flow back into the unit.
Unplug the refrigerator
Take the back off of the refrigerator
use socket wrenchs to undo and take off the water valve in the lower left corner of refrigerator.
Pull out and disconnect electrical connections
Pull out the 2 water tubes one for ice and 1 for water-white is water and black is ice.
install the new valve and connect the water and ice back in the new unit
connect the two power cords and reattach unit to the frame Turn water on and check for leaks.
If no leaks put back on refrigerator and plug in.
Wait 30 min to an hour for water to begin to flow back into the unit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chip from Mandeville, LA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
broken auger in the bucket assembly.
I ordered the wrong part, the ice maker assembly, because your diagram was not marked properly. I returned the part and you credited my account. Thanks. Ordered the new bucket. It worked fine. Now I have ice and crushed Ice whenever I want. Thanks.
p.s. I didnt use any tools, but to satisfy you I select nut driver.
p.s. I didnt use any tools, but to satisfy you I select nut driver.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dennis from AUSTELL, GA
- Parts Used:
- WR11X10009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
Fresh Food lever, under door, missing roller, make loud sound when closing door.
Removed tension spring, removed old lever, installed spring on lever, inserted lever in hole, re-attached spring to hook under front of refrigerator.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Johnnie from KANSAS CITY, MO
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
The Ground wires wasn't in same location on board
i had to improvise And relocate ground wire to get a proper ground .. That's all , the video was a GREAT HELP...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- robert from WOONSOCKET, RI
- Parts Used:
- WR51X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Freezer coils were iced up,was not cold enough,suspected the heater was the culprit
I had looked at videos on you tube,it looked simple enough. I mostly do my own repairs so I gave it a shot. the job went well,if you do not fix things around the house don't try to do the repair,find a handyman in your neighborhood to help you out,cheaper than calling a refrigeration man. It is not that hard to do.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- clyde from RIALTO, CA
- Parts Used:
- WR60X24484, WR60X10209
- Difficulty Level:
- Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
freezer drop temp to 12 degrees.recommended temp zero.
Replace the motor fan on condenser and clean the condenser
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Leif from Jacksonville, FL
- Parts Used:
- WR17X11168
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Intake hose to ice maker broke
After shutting off the h2o, I unplugged the refrigerator. Using the nut driver, I removed the cardboard backing. Then I removed the fitting where the inlet line to the ice maker and pried the old tubing from the unit. I then undid the clasp about 1/2 way up the back and removed the section that went through the back to the ice maker.
I then reassembled everything and plugged in the refrigerator as well as turning on the water.
Keep in mind that because h2o and electricity are involved. MAKE SURE THERE ARE NO h2o LEAKS.
I then reassembled everything and plugged in the refrigerator as well as turning on the water.
Keep in mind that because h2o and electricity are involved. MAKE SURE THERE ARE NO h2o LEAKS.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sharon from PEORIA, AZ
- Parts Used:
- WR12X10625
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
broken plastic freezer shelf front.
Emptyed shelf of food. Aligned new plastic front piece. Pressed front. Went right into place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Susan from Clifton, VA
- Parts Used:
- WR32X26198
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Broken Drawer
All I had to do was slide it in. But that's not what made me so thrilled with your site. What won my devotion was your site's ease of use (I couldn't find what I was looking for on GE's site) and the promptness of delivery. I will certainly use you again and recommend your services to my friends!
Was this instruction helpful to you?
Thank you for voting!