- Customer:
- Ken from Chapel Hill, NC
- Parts Used:
- WR60X10172, WR50X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Socket set
Refrigerator section too warm
I followed advice from other posts on this web site. The only thing additional I'd recommend is to take pictures of assemblies before you disassemble them. A neighbor gave me that useful tip. It should be noted that I first noticed my refrigerator failure back on June 22, 2012. I hired a reputable local repair service to fix it. They replaced the Defrost heater (item 618) and charged me $ 208.14. Then on August 22nd, I noticed that the problem resurfaced. I decided to fix it myself using info from site. The repair went well, and I'm hopeful that it will stay repaired. Kudos to this site!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jules from Crowley, LA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
failed light switch
I started removing the switch by prying on the right side with a screwdriver, when it emerged enough I used pliers to finish removing it. I then unpluged rhe wires from the bad switch and pluged them on the new switch and "poped" it into the hole.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- christopher from collegeville, PA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
no light in freezer
Connected the 2 wires and pushed in the switch until it clicked.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eric from Redmond, WA
- Parts Used:
- WR24X10186, WR24X10187
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The refrigerator and freezer door gasket's were leaking
The repair is very simple, the gasket sits in a channel in the door. Just start with a corner and pull the old gasket out. Once you've removed the old gasket, push the new gasket into the same channel. Make sure you've completely pushed in the new gasket all the way around the door. It's as simple as that. The repair takes less than 5 minutes per door.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Leroy Neal from Andrews, SC
- Parts Used:
- WR50X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
refrig.not cooling.freezer ok.
removed freezer panel,found the evap.iced up,put defrost timer into defrost. wated five min.no heat used hair dryer to defrost evap.found termination visually defective.replace defective part.no call back.Iam a EPA certified universal technician.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- paul from east hanover, NJ
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
refig light did not work
per your instructions
Was this instruction helpful to you?
Thank you for voting!