GSS20IBPCCC General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- James from Akron, PA
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Compressor Would not come on. Found the relay on the Main Board burned up. There was no electrical power to the compressor .
Ordered a new Main circuit Board. It arrived next day. Unplug the fridge to take away electrical power. Unscrewed the panel on the back of the fridge near the top. I then pulled the wire connectors off the circuit board. Gently pull the board off the plastic tabs. Push the new board onto the tabs. Reconnect the wire connectors. Screw the panel back on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Philip from Los Alamos, NM
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Cabinet very hot on sides, freezer not 0, running continuously.
Diagnosis of symptoms was condenser fan not running, due to faulty main board.
First: removed the cover over the main board, which was too hot to touch. Bad design flaw, no ventilation for the board, which I believe made it fail. We got another year of service with the cover removed.
Second: after reading people's experiences here, ordered the board and popped it in. (Note: needed a pliers to compress each of the 4 plastic studs holding the board in.) Works like a champ.
Third: did NOT replace the cover. At our altitude the air can't conduct enough heat to prevent cooking the board. Need to allow circulation.
First: removed the cover over the main board, which was too hot to touch. Bad design flaw, no ventilation for the board, which I believe made it fail. We got another year of service with the cover removed.
Second: after reading people's experiences here, ordered the board and popped it in. (Note: needed a pliers to compress each of the 4 plastic studs holding the board in.) Works like a champ.
Third: did NOT replace the cover. At our altitude the air can't conduct enough heat to prevent cooking the board. Need to allow circulation.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rudolph from Arroyo Grande, CA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
evap coil freezing up every 2 weeks
removed 2 - 1/4" screws and 2 phillip screws to take off the evap cover, then 2 phillip srews to take out the defrost heater assembly, replaced and put everything back together. no problem.
I GOT THE PART SO FAST THAT I WAS SURPRISED TO SEE IT THERE!
I GOT THE PART SO FAST THAT I WAS SURPRISED TO SEE IT THERE!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Pat from Pensacola, FL
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
No ice or water at the despenser. Compressor would turn off when the dispenser lever was pushed. There was also a loud buzzer sound for a couple of weeks prior to the board failing.
Pulled out the fridge and unplugged electric cord. Took off the back lower right side panel. Unplugged all the connectors and removed the motherboard. Replaced the motherboard and reconnected connectors. Replaced the panel and plugged it in. Works great!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- LEE from WILMINGTON, DE
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
clicking nose from mother board
pulled the board away from the 4 plastic pins, unplugged the wires and plugged them directly into the new noard, pushed board back onto the four plastic pins.......job completed in under 5 minutes. Fridge working fine now for over a week......no problems.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Holly Springs, NC
- Parts Used:
- WR50X10068
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Fridge getting warer and warmer
remove back panel inside fridge freezer side, everything frosted, unplug and used a hair dryer
1. Took out defrost heater and the bottom and tested (per this site) tested OK.
2. Then looked at the defrost thermostat, it was swollen with the top coming off. so i new it was bad
3.clipped and stripped the 2 wires, spliced in the new one with wire nuts and sealed them with silicone. All better
1. Took out defrost heater and the bottom and tested (per this site) tested OK.
2. Then looked at the defrost thermostat, it was swollen with the top coming off. so i new it was bad
3.clipped and stripped the 2 wires, spliced in the new one with wire nuts and sealed them with silicone. All better
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Coto de Caza, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Interior Light did not go on due to faulty switch
I ordered two switches, replaced both with a knife in 10 minutes. Interior light works, thanks.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- randall from coopersville, MI
- Parts Used:
- WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
refriderator not cooling consistetly
1 opened door 2. pryed cover off from cieling 3.cut and stripped wires on 4. sodered wires from old wires to new sensor. 5 insulated conection.6 put cover back on. This did not fix the problem it was the control moduel.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Aurelio from MAYS LANDING, NJ
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
clickking sounds
Unplugged unit.. Removed control board cover.. Removed all plugs from control board then removed board its self.. Replaced in reverse order.. Unit is working as new..
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cecilia from NATALIA, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Freezer would not freeze and fridge would not cool after power outages
I used a volt/ohm meter and checked for power to compressor and start run relays, diagnosis- was remove and replace motherboard
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jerry from Grass Lake, MI
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
freezer coils would freeze
Turned the power of to the fridge took the food out of the freezer put in the fridge took out all the shelves and took off the panel to get to the coils. I used a hair dryer and a shop vac to defrost the coils used the shop vac to suck up the water as the ice melted also put some paper towel in the drip tube so the water would not go to the drip pan. Took off old defrost heater which was a single heater the new on was a double heater fished out the blue wire from the left side of compartment and ran it down the right side plugged both wires into the heater mounted it into place and put everything back. Turned on fridge and it has been working fine ever since. Thanks for the last person that did this I read his review and it really was that easy
Thanks Jerry
Thanks Jerry
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kevin from BENSALEM, PA
- Parts Used:
- WR60X10220, WR60X10207, WR02X10098
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Noise from Condensor Fan and Fan Motor.
I watched the video provided by PartSelect twice, then proceeded with the removal and installation. It took me 40 minutes from start to finish. Piece of Cake. Everything works fine now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- charles from SCOTTSDALE, AZ
- Parts Used:
- WR55X10025
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Defrost not working coil iced up
Removed back wall cover over coil. Defrost all ice with a hair dryer. Cut white wires and replaced Temperature Sensor. It has been working for a week and no trouble at this time. If you have this system on your GE refrigerator do this before replacing the motherboard. I must admit I was thinking that was the trouble. Motherboard was replaced after 5 years old now 5 years later my thinking is this a 5 year problem. So try the Temperature Sensor.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Wylie, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Not cooling, Defrost issues, whining loud noises
Unbolted the back cover, pulled out old board, replaced with new bored and powered back on. It is working great now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from El Dorado, AR
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Will not defrost
The replacement part went in quite easily and quickly. The instructions sent with the part was pretty self explanatory. I have also replaced the defroster element, the defrost thermostat and now the main control board. After having done all this the thing is still freezing up. After disassembling the whole freezer section I found yet another temperature sensor (Also known as Thermistor). I'll replace this part next and if it still freezes up you'll be able to find it sitting on the curb. Thrown enough money at this ten year old fridge and a new one will be in order. Thanks Parts Select for reasonably priced parts, the posts to help with the repair and the fast shipping.
Was this instruction helpful to you?
Thank you for voting!