GSS22VFMDWW General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Glenn from Pembroke, NH
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers
Water running out of ice cube maker
After turning the water off, I removed the silver covering located on the left side bottom. The valve was connected to the frame on the left side. I removed the defective valve and replaced it with the new one. Everything was color coded and the hoses were different sizes, making it impossible to screw up. It was over so fast I thought I made a mistake.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- charles from leicester, NY
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
the top of freezer was warm and also refrigerator
I removed food, then removed shelves.
The light bulb and shade had to be taken out.
removed two screws from interior back panel.
defrosted cooling coils
removed two screws from defrost heater
took off two wires ...done
reversed procedure to finish installation
The light bulb and shade had to be taken out.
removed two screws from interior back panel.
defrosted cooling coils
removed two screws from defrost heater
took off two wires ...done
reversed procedure to finish installation
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Doug from Madison, WI
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set, Wrench (Adjustable)
Opend freezer door and found ice everywhere from dripping ice maker. Even with power unplugged water was still leaking through so I determined it must be the water valve at the back of the fridge that had failed.
Unplugged fridge. Shut off the water supply valve under sink. Removed lower access panel at back of the refrigerator (six screws). Removed single green screw holding water valve bracket and pulled assembly out to access wiring and hoses. It is a dual valve as one valve is for the water dispenser and one is for the ice maker. Disconnected the 2 electrical connectors (one for each valve). Unscrewed the compression fitting for the water inlet with 1/2 " wrench. Then the two water lines on the outlet which are quick disconnects. You must push the ring towards the valve and then the tubing can be pulled out by hand.
Reattach everything to the new valve and install and its ready to use.
Reattach everything to the new valve and install and its ready to use.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- monique from HUNTINGTON BEACH, CA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Wrench set
Freezer was frozen at the back panel and refrigerator didn't get cold anymore
Considering that I am a woman who knows nothing about repairing or let alone anything about refridgerator parts etc.... It was very easy.
First I went on line to see if I could even figure out what may be the problem with my refridgerator. After hearing similar stories on this site I thought I would try to order a new heating element since it wasn't that expensive and hopefully save me lots in $$$ have a repair man come out.
I removed the shelves in the freezer portion and then removed the back panel. I had to wait for the freezer to defrost, then I removed the burned out heating element which is about 10 inches long and replaced it with a new one.
It was so simple and probably would have taken less time if I had the freezer already defrosted.
Now the refrigerator is working like new and I fixed it all by myself without the help of my husband!!!!
First I went on line to see if I could even figure out what may be the problem with my refridgerator. After hearing similar stories on this site I thought I would try to order a new heating element since it wasn't that expensive and hopefully save me lots in $$$ have a repair man come out.
I removed the shelves in the freezer portion and then removed the back panel. I had to wait for the freezer to defrost, then I removed the burned out heating element which is about 10 inches long and replaced it with a new one.
It was so simple and probably would have taken less time if I had the freezer already defrosted.
Now the refrigerator is working like new and I fixed it all by myself without the help of my husband!!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chris from Kingman, AZ
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Refrigerator and freezer not getting cold enough.
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires..
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- carol from Du Bois, IL
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Defroster quit working. The freezer would frost up and not cool the fridge or freezer properly.
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires.Threw away the old defroster. Put the new one in. I had to reroute the blue wire over to the right hand side and plugged it in.Put the back on. put the shelves in and I was done! We had this done just about 3 years ago and it cost us about $175. The cost of this repair was only $38.05 with shipping and all! What a great deal! Thanks so much PartSelect!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alex from Madisonville, KY
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Refrigerator stopped cooling, back panel freezing, not defrosting
The repair itself is super easy. The heater harness comes with instructions that is easy to follow. The only issue I encountered is that my refrigerator had 1 heating element and you will get one with 2 heating elements. Because of this, the new connectors are on 1 side. Since my old heater had 1 connector on each end, 1 wire is too short if you route both wires the same way as before. The kit comes with an extra wire and directs you to splice the short wire and attach the extra wire with the included connector. I figured a refrigerator with a spliced wire is not a good combination so I rerouted the short wire to the other side along with the other wire. This allowed me to connect both wires without using the extra wire.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Melvin from Linesville, PA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator side of refrigerator/freezer wouldn't stay cool. Ice jam in cooling cools (due to burned out defrost heater) prevented proper air flow.
Removed shelves and light bulb cover. Then removed the two screws that hold the back wall of freezer compartment in place and removed cover. Thawed ice jam with hair dryer. Removed the two screws holding heating element in place and pulled element out far enough to disconnect the two wires. Reconnected wires to new element and put everything back together.
Installation instructions which came with new part were accurate and very easy to understand.
It took about 30 minutes total.
Installation instructions which came with new part were accurate and very easy to understand.
It took about 30 minutes total.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- LaNeisha from Kerrville, TX
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Burned out Freezer defroster element
I had done this repair almost exactly 2 years ago. I also read in this forum about a guy who said he had to do it every 2 years... bad part design.
However, GE has replaced the original single element with a dual element, and that is what PartSelect sent me. I had to splice one wire, but the instructions were clear and it went like a breeze. Oh, and the part arrived less than 3 days after I ordered it with standard shipping. Way to go, guys! Thanks!
However, GE has replaced the original single element with a dual element, and that is what PartSelect sent me. I had to splice one wire, but the instructions were clear and it went like a breeze. Oh, and the part arrived less than 3 days after I ordered it with standard shipping. Way to go, guys! Thanks!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ed from Orient, OH
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Frig AND freezer side not cooling
This is a repair INSIDE the freezer. Turned off unit.. Unplugged. Removed shelving on freezer side. Removed freezer draw rails (4 screws total.) Removed 2 screws that hold rear panel in place at rear of freezer side (this is inside the freezer). Carefully removed metal panel by pulling from the left (side that does not have shelving clips. As noted on this website and other users, the freezer coils were incased in ice. Thawed with a hair dryer (put towels in bottom of freezer-ice was pretty heavy in mine). When thawed, remove heater element by removing 2 screws that hold it to the aluminum bracket. Then remove wires on each end. Simply install the new emelment by attaching wires back on heater and screw new unit in place. (My original heating element was a single element-you could very easily see where the heating coil inside the glass tube had shorted out. My replacement heater was a 2 element unit. This did not pose any problem at all-installs in the same manner-good directions are provided.). Replace all parts in reverse order. It's that simple. Saved probably $150. This site is wonderful! Fast shipping and the users install tips/notes are fantastic!! Will shop here again if I have to (have a Maytag washer that isn't draining and going into spin-bet the fix is on here somewhere!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Patricia from Naples, FL
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Refrigerator would not cool
I followed the easy instructions included with the replacement part I ordered. I removed the back of the freezer, unpluged the broken heater and replace with the new heater. The heater just plugged in, very very simple. I put the back panel bach on with the two screws and it perfectly. Not back for a girl!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ABE from MOHEGAN LAKE, NY
- Parts Used:
- WR71X10232
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
my shelf inside door was broken
i just took it out and put the new one in.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Glendale Heights, IL
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
Light would stay on when door closed
Extremely easy repair, the hardest part was getting the old switch out. I used a pair of needle nose pliers to squeeze the tabs in and it came right out.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alan from Ruther Glen, VA
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench set
My water hose broke, the valve is 1 use.
1. remove back shield of fridge.
2. unscrew old valve.
3. remove electrical connections.
4. remove white inserts on new valve.
5. cut feed hoses next to old valve.
6. place white inserts on hoses.
7 insert hoses into recepticals on new valve.
8 shut off water supply to fridge.
9. remove water suply line from old valve.
10. attach water supply line to new valve.
11. connect electrical connections.
12. bolt valve back on to fridge
13. turn on water supply to fridge
14. test both ice maker and water dispensor
15. replace back shield to fridge
2. unscrew old valve.
3. remove electrical connections.
4. remove white inserts on new valve.
5. cut feed hoses next to old valve.
6. place white inserts on hoses.
7 insert hoses into recepticals on new valve.
8 shut off water supply to fridge.
9. remove water suply line from old valve.
10. attach water supply line to new valve.
11. connect electrical connections.
12. bolt valve back on to fridge
13. turn on water supply to fridge
14. test both ice maker and water dispensor
15. replace back shield to fridge
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chris from Rainier, WA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Freezer coils were covered in ice and fridge was warm
First I removed the freezer compartment backplate by unscrewing three screws. Then I unscrewed the 2 screws holding the heater element in place. While holding it in one hand I pulled the wires off, one on each end of the element. Then replaced it with new part and put it all back together. Piece of cake.
Was this instruction helpful to you?
Thank you for voting!