Customer:
Greg from Damon, TX
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Fan was not running to circulate the air; found resistors burned on main board
Removed the board cover from the back, removed old board, installed new board, installed cover.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Allen from Smithland, KY
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Refigerator quit running
Removed back cover from unit. unpluged wirring harness installed new control board and refigerator runs lik new
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from Marrero, LA
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Main Board failed
Part arrived 2 days before anticipated. I was able to keep my fridge running long enough to get the new part in, which took no time at all. The Main Board relay would start clicking and the compressor would shut down. By unplugging the top right plug for a minute and plugging it back in I was able to keep it running for a few hours at a time. Good enough to keep my food from going bad. Thr part was an easy plug in replacement, was a good price, and works great.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jonathan from NEW ORLEANS, LA
Parts Used:
WR55X10942
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Refrigerator and freezer would stop cooling. Would happen suddenly without warning. Reset of refrigerator would solve the problem and it would run fine for several days before doing it again.
Only tool I used was 1/4 inch socket. Using the 1/4 inch socket, the screws were removed from the panel covering the control board. (this is on the back in the lower right corner). When this panel is off you are looking at the control board. Next remove all the plug in connectors. Don't worry about remembering where they go. They all are different and can only go in their specific place. After removing the connectors, pull the board out. Replace the plug in connectors before putting the new board back in , then snap the board back into place.(held in by four pins). Replace the cover.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jodi from Benton Harbor, MI
Parts Used:
WR23X10725
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Light out
Turned off the breaker to the fridge because I couldn't reach the power plug to unplug it . Use small flat head screwdriver to pop out the piece, disconnected the rubber prong connectors, inserted the new piece into the rubber prongs snapped it back into place. Flipped the breaker back on and prayed it worked. It did and I saved myself $120 service call.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
paypal_shipping_address from Ripon, CA
Parts Used:
WR23X10725
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Light would no longer turn on
I watched the video online, followed the instructions and within minutes had the part installed. The frig light was working once again! I will say the original switch was very snug and I had to do some very minor scraping of the plastic to get the new part to slide in.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from BERLIN, MD
Parts Used:
WR07X26748
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
refrigerator would not get cold
got on part select web site and found other customers that had same problem and on their site they had comments from them to fix problem. I then took off back panel on frig where compressor is by removing 6 screws and found the relay attached to the compressor then pressing down on holding spring removed 2 wire alligator clips and it was bad ordered one from part select put the new one on an frig was fixed. entire fix took about 30 minutes from isolating problem to fixing it. thank you part select
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Glenn from GLENSIDE, PA
Parts Used:
WR50X10068
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
The refrigerator and freezer were running hot.
I followed the onsite video and had no problems. Shut off refrigerator, removed storage trays and bind, removed the rear panel under the light, identified the orange and pink electrical wires and cut them. Spliced the new wires of the thermostat with refrigerator wire and capped them, applied electrical tape to insure no moister makes contact with wires. Replaced rear panel and storage racks and bind. Plugged in the refrigerator and it is operations like new. I was about to purchase a new refrigerator for $ 1,300.00 and the thermostat costed $ 13.00. What a Christmas present!
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Aurelio from MAYS LANDING, NJ
Parts Used:
WR55X10942
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
clickking sounds
Unplugged unit.. Removed control board cover.. Removed all plugs from control board then removed board its self.. Replaced in reverse order.. Unit is working as new..
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Harry from DURYEA, PA
Parts Used:
WR55X10025
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
both freezer and refigerator were warm.
I watched the video online and it said there were three sensors in the refrigerator, two in the freezer and one in the refrigerator. I only ordered one sensor and was going to try the one in the refrigerator first. He said the upper one in the freezer is the most difficult, but is usually the problem. So, I replaced the upper sensor and tried restarting the unit. Everything went well and it fixed the problem.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Douglas from LAFAYETTE, LA
Parts Used:
WR02X11331
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Squeky Evaporator Fan
I made my wife fix it.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Catherine from SEATTLE, WA
Parts Used:
40A15
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
The light inside the oven had burned out
0. As a safety precaution, unplug the range or hit the relevant fuse breaker before you start. You might also want to grab a flashlight. Definitely do not try to do this while the oven is hot.
1. Pinch the wire over the light bulb cap to remove it. This is inside the oven at the back.
2. Pop off the hemispherical glass cap.
3. Unscrew the old light bulb, and screw the new light bulb in its place.
4. Put the cap back.
5. Secure the cap by putting the wire back in its slots on the cap.

No tools needed, the cap is just held in place with pressure from the wire.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Terry from Cheyenne, WY
Parts Used:
WR55X10942
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Periodic and intermittent "clicking," during which the lights on the temp control unit would go out. When clicking stopped and lights returned, temp control unit was not accepting adjustments in temp
Had friend assist in pulling fridge out from it's area so that I could access back. Unplugged unit. For the bottom freezer units (mine) the compartment containing the main control board is middle of the fridge and on the left. Took off the protective metal plate and then followed the video demonstrating the repair. One other discrepancy between the video and the instructions that came with the new main control board, is that the instructions suggested locating and cutting some other green wire to the compressor unit. I chose not to do that, as the unit was otherwise working fine as is prior to my main control board going south.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ronald from HILLSBOROUGH, NC
Parts Used:
WR72X10072
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Broken slide
Removed 2 screws and removed the old slide. Installed new slide and 2 screws . Done.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from ROSEMOUNT, MN
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of freezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GTH22SBSARSS