John from Mount Royal, NJ
Parts Used:
5303918277
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Water in the ice bin freezing all the existing ice into clumps
You have to blindly unscrew the two screws along the side of the ice maker. Once that is done simply remove the ice maker to the side to gain access to the electrical plug. Undo the plug and remove the ice maker completely. Install the adapter on the new ice maker and install it in much the same way you removed the old. I started the (2) 1/4" screws before installing the new ice maker to make it easier to hang. Pay careful attention to the wire harness and dress it out of the way. Finally tighten the two screws and make sure the bail wire is down to begin ice making once again.
20 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rebecca from Gautier, MS
Parts Used:
241559801
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Light Socket short
- Unsnapped old light socket from top of Frig
- Disconnected elect wires
- Reconnected elect wires to new light socket
- Snapped new socket in place
- Done in less than 2 min.
22 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JAMES from HENDERSON, NV
Parts Used:
5303918277
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Ice Would Not Work - But Water Disp Did
Shut off water/power - pulled tray -loosened two screws holding ice maker - lifted it up and off - unhooked power connection installed new maker in reverse of above - power supply line was much to long but just pushed it under the ice tray ( away from the maker ) prior to ordering looked at comments from others regarding installation
17 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
RONDAL from MONROE, NC
Parts Used:
218169802
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
refrigerator side stopped cooling
Noticed no cool air was coming from the vent on the refrigerator side. After cleaning out the freezer side, I noticed that the air intake at the bottom of the freezer was frosted over.I removed the metal panel and discovered the coils were completely frosted over so I found the defrost timer located at the bottom left corner of the refrigerator. took a screwdriver and turned it very slowly to force a defrost. i watched the coils for awhile and noticed that the heat element would never deice. so I thought it may be the thermostat clamped to the top of the coil might be bad. I unplugged the thermostat and plugged the heat element coil directly to wires feeding to the thermostat. On my refrigerator the wire connectors will allow to bypass thermostat. After waiting twenty minutes, I forced another defrost cycle with the timer and noticed the heat element would still not defrost. So i unplugged the heat element and took a test meter and checked the wire connectors and found one twenty volt at the connectors. So, therefore, I determined it must be the heat element itself. Even though they rarely give trouble. I found the service diagram on the back of the refrigerator in a plastic pouch, and it said the ohm resistance should be twenty two. My element read 145 so that also pointed to a bad heat element. I took the screw out that holds the coil in, lifted it about two inches, and pulled the bottom of the coil out just enough to remove the heat element from the coil and discovered it had a crack in it. It must have been a Monday at the factory, because the heat element looked like it had been warped while being installed.I ordered a replacement element and installed it. I works as good as new. I do electrical work for a living, so this was pretty easy for me to figure out.
16 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Beavercreek, OH
Parts Used:
5303918277
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice make just stopped
I want to first say that before I ordered this part from "Part Select" I first went and talked with a local appliance repair shop. They quoted me a $120 charge to come out and check the problem. Then $30 and hour service fee, plus parts. He provided me a quote of about $250 for the job.
I found this part easily on the web site $77. It was very easy to instal. The only problem I had was the fact that in the side by side it was very difficult for me to get two hands inside the freezer to install it. (I have wide shoulders). Two screws loosened, no need to remove them. Just life the entire unit straight up. Unplug wire harness. Then just reverse order. Could not be easier. If you can change a light bulb you can do this.
16 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dee from Central Point, OR
Parts Used:
5303918277
Difficulty Level:
A Bit Difficult
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Our Ice Maker drove us nuts with noise from cubes getting stuck.
I purchased the replacement part (no instructions sheet) from another company, not this one, that cost 2X's a much as this company. So I sent it back and ordered from this company. Got it faster then the post office sends us the stamps we order by internet and this ice maker had instructions.
Our's is a side by side refrig, so working space is limited but do-able. The old ice maker has made a clicking noise for years while trying to push the cubes out of the tray. They would get stuck and refreeze, sticking half way out of the tray.
I loosened the 2 screws with a socket driver (which are difficult to see), raised the unit up and off the screws. Unplugged the power & out it came. Removed the bracket on the side as instructed to attach to the new ice maker and in the trash the ol' ice maker went. Set the new ice maker on the screws, plugged in the power, tightened the screws and walla. A quiet ice maker. In fact, it would startle us the first day as we didn't hear the clicking noise indicating it was stuck. All of a sudden the cubes just dropped into the container. Alright! Don't know why I didn't do this years ago.
17 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Alexandria, VA
Parts Used:
5303918277
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Ice maker burned out
Removing the old unit was easy enough, just loosened two screws that attach unit to side of freezer and disconnected the wiring harness. But the new unit never goes in quite as easily because it's always just a little different from the original. In this case, the wiring ended up being about six inches longer and the excess had to be stuffed behind a shield at the rear of the unit. Theoretically, the wire could have been pushed back through the opening, but it got jammed and wouldn't go. I had to remove side rails and pry the shield forward in order to get the wiring back out of the way. The unit is a narrow side by side, so there wasn't a lot of room to move around. But it wasn't difficult, just tedious. I had to make sure the wiring did not come into contact with the heating element at the bottom of the icemaker. Once installed it worked great.
17 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ted from Glendale, AZ
Parts Used:
218859701
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench (Adjustable)
No water from dispenser in front or fill the icemaker
Since we will be working with water and do have an electrical connection nearby, it will be best to unplug the refrigerator to do this repair. It should only take about 15-20 minutes to complete the repair so your contents in the refrigerator should be fine.

1-SImply pull your referigerator away from the wall and unplug it.

2-Locate water supply valve and turn off water to refrigerator by closing the water valve.

3-Remove two 1/4" screws that hold the black "cardboard" cover at the bottom right corner of refrigerator.

4-Then locate the two 1/4" screws holding a light blue valve assembly, again in the bottom right corner of refrigerator. Remove screws and assembly will be loose.

5- Remove water line from the top of the valve assembly you just loosened.

6-Then unscrew the large plastic nut on bottom of valve assembly.

7-Unplug the electrical connector that is on the top of the valve assembly.

8-Install the new valve by reversing the installation. Plug in electrical connector, tighten water line on bottom of assembly, re-attach/tighten main water line on top of assembly- and re-attach valve assembly to refrigerator and re-install cardboard cover. Turn on water supply to refrigerator and check for leaks. Don't forget to plug the refrigerator back in.

Thats it! Problem solved!
16 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steve from ORANGE, TX
Parts Used:
241798231
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Ice maker quit working
Followed the steps in the video on your site, really easy to do.
16 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sophia from San Antonio, TX
Parts Used:
297216600
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Defrost function in freezer was not working, while the refrigerating side was warm
1. Turned off and unplugged the refrigerator.
2. Removed the lower back panel inside the freezer with a screwdriver.
3. Unplugged the thermostat. (No tool is needed)
4. Ordered a new thermostat from PartSelect and it arrived in 2 business days.
5. Plugged in the new thermostat..
6. Put the lower back panel inside the freezer with screwdriver.
7. Plugged in the Refrigerator and turned the power back on.
8. It is working again!!!
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
paul from traer, IA
Parts Used:
5303918277
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
ice maker would not make ice
un plug fridge. removed ice maker from fridge. loosen 2 mounting screws. lift unit in slots to get over heads of screws. unplug wire harness. remove cover. remove 3 screws from control housing. remove 2 motor mounting screws. unplug motor wires from switches w/needle nose. installation is the reverse. plug in fridge turn on icemaker. takes 10 to 15 min to start to cycle.
easy and cheaper than new fridge or ice maker
16 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from New Orleans, LA
Parts Used:
241885001
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Original gate broke at the swivel point
I removed the old gate by using a flat head screw driver to pry open mouth. I then removed 2 bolts that held on the cage that hols the ice crushing blades. Then I inserted the new gate and used a screw driver to pry the mouth open again (it was more difficult to insert than remove). I then popped in the new gate and re-assembled the cage. It worked on the first shot with no problems!

This is the 3rd time I have attemped and successfully repaired major home appliances myself after the warrenty ran out. I'm sure I could buy a new appliance for the money I saved.
15 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Doug from Folsom, CA
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Fridge side warm. Freezer was ok.
Popped off the front plastic cover on the bottom of the fridge, under the doors. Two screws held the defrost timer on under the front side of fridge (below freezer door). You can't really see the timer except for the adjustment knob that is accessible through a hole. Once the screws are removed, disconnect the wire plug and remove and replaced unit. Works fine ever since.
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Vaughn from Virginia Beach, VA
Parts Used:
218518700
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Leak in the water tube elbow
First I remove protection cover,then removed the elbow pressing in on the gray coupling housing at each end of the elbow.Mark each piece of water hose before removing the elbow with marker(black)it helps when replacing new elbow.The new elbow slides on each end of water hose ,connect the end to the hose coming out of the door first. Replace protection cover. No more leak.
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Chetek, WI
Parts Used:
218169802
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
The freezer coil was frosting up blocking airflow to refrigerator side
I first unplugged the refirgerator. Note the time because the refrigerator should be unplugged at least 30 minutes before plugging back in (see end for why). A trouble light is necessary to see adequately. I removed the shelves and draws and put food in a picnic cooler. I took off the lower panel in the back of the freezer, and defrosted the coils with a hair dryer. I unplugged the wires to the defroster, and then the screw holding the coil to the back of the freezer side. I lifted up on the coil unit to clear the blade that inserts into the drain. I removed the bands on the top of the coil that hold the heating unit in place. I tilted the bottom out when there was clearance, and pulled the defrosting unit down and out. I replaced the new one, and reversed the procedure, and then plugged the wires back into the new defroster unit. The bands on the top should be secured before putting the coil back in place, as well as the foam spacers on top of coil, put the two wires back in the plastic clip that keeps them away from the fan and pipes. Replace lower freezer cover panel and screws. Put shelves and food back in. If at least 30 minutes have passed, plug the refrigerator back in. If you don't wait that long, their will still be pressure in the compressor and it will not start to cool properly right away. It works perfectly now. TIP: check the end of the drain hose periodically by taking off the lower back cover and pull th hose out - not hard to do. Mine plugged from dust and lint build up backing up into the end of the hose so water didn't drain out, and ice built up causing the defroster coil to burn out. I cut a little off the hose so the water level would not rise up into the hose, but the hose would still stay in place in the plastic holder.
11 of 11 people found this instruction helpful.
Was this instruction helpful to you?