Customer:
Costas from new hyde park, NY
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Overheat coils at the bottom inside of the freezer
I pick up very fast at these kind of small jobs but because of my very busy schedule I decided to call (2 times) technicians about my problem but none of them had any idea. About my repair, I removed the grill at the bottom of the refrigerator, unscrew a small plate (located on the bottom left side) that's holding the defrost timer. I plug on the new part, screw back the plate with the defrost timer and that was it. Don't forget to turn clockwise with your finger the timer until you hear a "click" and then turn it slightly more to the right. There is also a video on U-tube.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Darryl from Russellville, KY
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
fridge side was getting warm.
open freezer door two screws just below unscrew slide piece to side unplug reinstall very simple.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Dunnellon, FL
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
both ref&frez were hot
1 went with maj 69% said defrost timer. NO. 2 went with second choice run cap NO. 3 went with my thought, ( PTC Starter ) why not, most exp part. Fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Montross, VA
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer dripped water and items thawed but compressor ran.
Instructions from partselect were very clear and probable cause made it easy to narrow things down. I have the manual for the refrigerator that shows the location of the defrost timer. Very surprised that it turned out to be a cheap and easy fix.
Was this instruction helpful to you?
Thank you for voting!
Customer:
gustavo from gilroy, CA
Parts Used:
5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Fridge was warm and no cold air was coming in
The repair was straightfoward. The evaporator motor I received from partselect was a different model with different wiring configurations. I cut the wires from the new motor per the instructions I received with the new motor and I did the same with the wires that connect to the fridge. Once I matched the wires and secured them with electrical caps I began to put the evaporator motor to the base and started screwing the screws the way I took them off. Once I connected the wire harness to the back of the freezer and turned it on I noticed a big difference in air flow. I was surprised at how easy it was to fix my refrigirator problem. It's been a few weeks now and the fridge is cold and working like it should. Don't be afraid of this task. it's very easy and will save you a ton of money. Thanks partselect.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Long Beach, CA
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers, Socket set
Freezer wouldn't go in to defrost cycle
After some troubleshooting to ensure the thermostat and heating element were working, determined that the defrost timer was the problem. With the defective part, I was able to manually advance the timer to activate the defrost cycle, but it wouldn't do so on its own. Unplugged the refrigerator from the wall. Timer is located in the refrigerator compartment at the very top. The compartment houses the cooling thermostat, the light bulb and the defrost timer. Using 1/4" nut driver, remove 4 screws holding compartment cover to top of fridge. Lower a bit to access electrical wiring. Wiring harness can be unplugged to work on the timer away from the fridge which makes it a bit easier. Timer is mounted with 2 phillips head screws. Remove screws and unplug timer from wiring. Install new timer, plug in wiring, secure with the phillips head screws and remount entire compartment.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerry from Apache Jct, AZ
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
changed defrost timer
followed the video very esay
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bertha from Lakewood, CA
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Refrigerator warm and freezer defrosting too quickly.
1. Disconnected electrical. 2. Removed upper console in refrigerator by removing 2 nuts. 3. Disconnected wiring from console. 4. Removed 2 screws from defroster timer part and pulled off from connector. 5. Replaced with new defroster timer and put everything back together. Thank you Steve for the U-Tube step by step video.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mainul from Portland, OR
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The refrigerator part was not cooling enough
I watched the video online where it described the troubleshooting tips for this type of symptom. So I knew exactly what the problem was which is the defrost timer. After the part came in I just unscrewed (4 screws) the box which houses the thermostat and the defrost timer from top ceiling of the refrigerator section. Then I just unscrewed and unhooked the old defrost timer and replaced it with the new one. After finishing the installation I turned the fridge on. At first nothing happened. So I turned the dial on the defrost timer with a flathead screw until it clicked and the fridge came alive. I waited for an hour or so. The cooling cycle completed and the fridge stopped as expected. When I opened the door I noticed the interior is much colder than before and right after closing the door the fridge hummed back into life again. So I know my fridge is working again. Thanks to PartSelect for providing the right part for my refrigerator. I will definitely buy from them again if anything goes wrong.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Collegeville, PA
Parts Used:
5303917954, 215846602
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers
Refrigerator section warm, freezer working properly
I followed the advice of many people with the same problem, and replaced the Defrost Thermostat and Defrost Timer. Both repairs were relatively easy, and the problem appears to be solved. The replacement of the Defrost Timer is very easy (about 30 minutes), and I wish I had stopped at that step and waited 48 hours to see if that fixed the problem. But, I wanted to replace both parts that I had purchased - - In my refrigerator, access to the Defrost Thermostat is through the back of the freezer panel. Not too difficult to get to the area, but I had a bit of a problem in replacing the part, and might have been better-off to see if step 1 fixed the issue. The problem that I ran into is that I don't have a crimping tool, and crushed both of the connecting sleeves when trying to 'crimp' them with a set of wire-strippers. Rather than to invest in a crimping tool, I connected the wires and sealed with electrical tape - - Now that the issue is resolved, I will likely re-open and use a proper connecting sleeve (with a proper crimping tool). My advice is to buy both parts, and replace just the Defrost Timer first. Chances are good that it may fix your problem, and you are only out $20 for the second part, which you can leave in your junk drawer until you may need it some day! All in all, it was a great way to spend $40 and avoid a costly service call!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tommy from Belton, TX
Parts Used:
215846602
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers
Coils in back of frezzer freezing up,and freezer compartment not freezing
1st. replaced the defrost thermostat pn 5303918214 did not fix it next replaced the defrost timmer pn 215846602 that did not fix it,next replaced the defrost heater pn 5303918247 still did not fix it,has the same problem as when I started I don't know what to do next guess will call for a service tech to come out,or get a new refridgerator. Looks like I wasted my money on these parts. Refridgerators are not as easy to fix as yall make them out to be. I have to say all the parts were easy to install and your instructions and videos were great, they just did not fix my refrigerator Thanks Tom
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eric from San Angelo, TX
Parts Used:
5308000010, 5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Fan Motor was making noise and freezing up.Fan was missing one blade.
Removed screws that fastened bracket to fridge. Next, I replaced the motor and carefully lined the brackets up so the motor would rotate smoothly. Put the fan blade on the motor and screwed the brackets back on the fridge. Motor kept popping out of alignment while I was screwing the brackets back in but I kept snapping it back in till it stayed.
Was this instruction helpful to you?
Thank you for voting!
Customer:
wayne from marietta, GA
Parts Used:
215846602
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
fridge not blowing cold
bottom left cornerof fridge defrost timer replaced two bolts and a wire
Was this instruction helpful to you?
Thank you for voting!
Customer:
HUNG from KENT, WA
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
refregirator too warm
I order defrost timer then replaced it but it seemed doesn't work. I order defrost thermostat again then it worked fine until now. Thanks. Part selects.
Was this instruction helpful to you?
Thank you for voting!
Customer:
hugh from delray beach, FL
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Frig did not run
Simply replaced the defrost timer located inside the frig just behind the temp dial. Very easy job. Removed the 3 screws holding the temp sw and light assembly. Removed the defrost timer w/ 2 screws and put i all back together. 15 mins at most. Suggest you watch the install video for pointers.
Was this instruction helpful to you?
Thank you for voting!