- Customer:
- Jeff from Lakeville, MN
- Parts Used:
- 240505801
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
light switch did not operate correctly
Piece of cake! The new part just plugged in to socket and back into fridge frame. Appreciated how easy it was to order this part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lori from Catskill, NY
- Parts Used:
- 240338101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The door shelf broke.
Very easily did the repair -- popped the new door shelf right in the place of the old one! No tools needed, no hardware, easy! The part actually measured 24 3/4 but the replacement part said "26 inches" on website & this was THE replacement part. Put this off for so long--ordered part and recd within 2 days, great!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Henry D from PETERSTOWN, WV
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
sometimes it would go into defrost and would not go back to cooling.
I called the repairman who diagnosed the problem as a thermostat then had to order a thermostat took about 2 weeks to get back and install (cost little over $100). did good for about two weeks and same problem reoccured. I decided it was defrost timer and ordered from this site for $19.95 including shipping. I got on ( you tube ) and got instructions(recommend you tube) for DIY install about 15 to 20 minutes. Has been running great for about 3 weeks. ( YOU TUBE IS GREAT FOR A DIY REPAIR ON ABOUT ANYTHING)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Frank from IVYLAND, PA
- Parts Used:
- 5304458371
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Over a few days duration the ice maker stopped producing cubes , after a basic examination of the unit I found a web site that provided parts and instruction on self repair .
so basically if you can make toast , you can do this repair....loosen 2 hex head screws ,lift up on the ice maker and separate from wall of freezer , unplug the wire harness ,it is now OUT , swap the water level indicator to new part [30 second job ] Install the new part in reverse order as mentioned above... enjoy your ice
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JUSTIN from NEW BRAUNFELS, TX
- Parts Used:
- 5303918202
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Top cools bottom is weak
Unplug, remove 2 screws off back panel inside the freezer. Cut wires on old one and crimped in new one. Light to melt the shrink wrap that came with it. Pretty easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Callie J. from YORKTOWN, VA
- Parts Used:
- 5304511738
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Freezer light bulb went out.
Used my hand to unscrew light bulb.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alan from SAN MATEO, CA
- Parts Used:
- 316538904
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Repaired Oven Range Light Bulb
The bulb has a plastic clear cover. That cover can just be carefully removed using a screwdriver. It's held in by a metal bracket. After you remove the cover. You'll just need to replace the bulb and then re-install the cover and bracket.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Danny from PUEBLO, CO
- Parts Used:
- 241798231
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Drive great stripped for ice eject. Heater bad
Loosened the 2 bolts 4 turns where it mounts inside the freezer. Lift maker off the bolts unplug 1 plug. Reverse to install.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Leah from Tecumseh, OK
- Parts Used:
- 242252603
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
After installing new ice maker water was not running into the ice maker.
Shut off water supply under the sink. Removed old valve and installed new valve. Turned water back on and within a couple hours the first batch of ice made.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Terry from KEYSTONE, IN
- Parts Used:
- 5303918277
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice maker leaking, then would'nt shut off.
Ice maker is held by 2 screws just above the unit, on the wall of the refrigerator. You can't see the screws, so borrow your wife's makeup mirror. Shine a light into the refrigerator, and using the mirror, locate the two screws, holding the unit in place, on the wall of the refrigerator. Using a nut driver, or socket wrench, with a 1/4 in socket, loosen up the two screws, but don't remove them. Bump the unit upwards, and away from the screws. (BEFORE doing anything!! Shut off the water supply, unplug the refrigerator) When you get the unit freed up, just unplug the old unit, and install the new one. You don't even have to worry about the water lines, and you'll see why, when you get the old unit off. Just reverse the procedure, installing the new unit. Very Simple, 10 to 15 minutes tops.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from KNOXVILLE, TN
- Parts Used:
- 241798231
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice maker would dump ice one time and then stop. Turning the ice maker off for a minute and back on would repeat the process.
I removed the two side mount screws with a screwdriver and disconnected the electrical plug to the ice maker to remove it. I reversed the process to install the new one.
It was the thermostat that was the problem, but I chose to replace the entire ice maker for only $25 more.
It was the thermostat that was the problem, but I chose to replace the entire ice maker for only $25 more.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edward from GROTON, CT
- Parts Used:
- 241798231
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice maker stopped working. Part needed to repair it no longer available so had to replace the whole icemaker.
Loosened the two mounting screws (no need to remove them), lift off the icemaker and unplug it. Reverse the order and done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jack from WALLING, TN
- Parts Used:
- 241639502
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Socket set
Fridge started making a loud racket. Condenser Fan Blade then disintegrated to dust and pieces. The plastic had degraded significantly.
The repair itself total time was quick and easy. Since the original fan blade blew apart, it was only a matter of putting the new one on in it's place. This can be done by feeding the blade between the cowling and Condenser coil and applying pressure to get it on the shaft.
If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.
In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.
Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.
Hope this helps someone. :)
If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.
In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.
Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.
Hope this helps someone. :)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Cleveland Heights, OH
- Parts Used:
- 240338101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Needed to replace shelf
I can't believe I put if off so long... so easy to do and PartSelect was very fast, efficient, and the cheapest vendor for my part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from San Diego, CA
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The refrigerator wasn't cold enough.
I removed the plastic shroud on the ceiling of the refigerator, unscrewed and unplugged the old defrost timer, and replaced it with the new one. I reinstalled the shroud with the new timer installed.
Was this instruction helpful to you?
Thank you for voting!