Customer:
Nathan from WELLS, ME
Parts Used:
5303918202
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
Refrigerator and freezer running to warm.
I watched the video on how to change the defrost thermostat. I removed the back cover inside the freezer then I pulled off the old defrost thermostat and then using a pair of wire cutters I cut it off and then bared a little of both of the wires and then slid the heat sherink and wire connectors on the existing wires and then slid the other ends of the wires into the wire connectors then crimped the ends of the connectors and then tried using heat on the heat shrinks but still used rubber electric tape over it. I clipped the new thermostat were the old one was and then reattached the freezer wall cover and plugged the refrigerator back in. 24 hours later I checked the temperature in the refrigerator and freezer and both are running a lot colder.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jack from WALLING, TN
Parts Used:
241639502
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
Fridge started making a loud racket. Condenser Fan Blade then disintegrated to dust and pieces. The plastic had degraded significantly.
The repair itself total time was quick and easy. Since the original fan blade blew apart, it was only a matter of putting the new one on in it's place. This can be done by feeding the blade between the cowling and Condenser coil and applying pressure to get it on the shaft.

If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.

In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.

Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.

Hope this helps someone. :)
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Arsen from Glendale, CA
Parts Used:
5303918202
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
i smell very bad smell coming from refrigerator
I started look inside ,disconnected power, and open all possible compartments to see any burned part. Fortunately I fined a small part look like melted and then i went online and make my research .Then i ordered that part and change it.
7 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Duson, LA
Parts Used:
240530701
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Broken support rail
First, I removed the screw holding the support rail and, because of using super glue to attempt a temporary fix, I had a little difficulty in removing it from it's location.

Since I have "tremors" next time email me a repairman.

Thank you.

Robert L. Enox
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kristy from Woodbridge, VA
Parts Used:
240535101
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
top shelf broke; replaced it
It just snaps in place, no biggie. What was a big deal was... that I ordered the part one day at like 2pm and got it the next day by about 2pm. That was very strange!!! Never expected that sort of delivery. Very nice!
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Pilesgrove, NJ
Parts Used:
240360801
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Lost the temperature control know
The knob came in the plastic package. It was the correct part. I opened the package and placed the knob on the prongs. Now it works fine.

Thanks
John S.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JOHN from ABERDEEN, NC
Parts Used:
240530701, 240530601
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
RIGHT SIDE SNAPPED OFF
REPLACED BACK SCREW AND SCREWED THE NEW ONE INTO PLACE,REPLACED BOTH SIDES,RIGHT AND LEFT...SUPER EASY.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mary Jane from GREENVILLE, SC
Parts Used:
240383901
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
The shelf broke
I ordered the part and snapped it on the door.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sherry from Newberry, SC
Parts Used:
5303918202
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
the freezer frosted up and the fridge was not getting cold.
I watched the instructional video and did what it said.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steven from PARRISH, AL
Parts Used:
240530701
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
BROKEN RIGHT DRAWER RAIL
REMOVED STUFF FROM SHELVE AND THEN REMOVED SHELVE AND TURN UPSIDE DOWN REMOVED SCREWW AND REPLACED RAIL AND DRAWERIN TRACKS REINSTALLED SCEW AND RETURNEED TO REFRIGERATOR
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
will from bushnell, IL
Parts Used:
5303918202
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Freezer froze up/ Fridge ran warm
Thawed out freezer, I recommend laying a couple old towels in freezer to soak up melted ice. Replaced old thermostat with new part. Removed 2 screws, removed back plate, unplugged 2 connectors and cut 2 wires. Crimped in new thermostat and repositioned to original part location. Reconnected plugs as I reinstalled back plate. Installed 2 screws and connected power. Works like new! Trouble shooting and part installation video is very helpful, great site!
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marcos from E STROUDSBURG, PA
Parts Used:
240362601
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
The Refrigerator was not cooling properly. At 40-45 degrees milk spoiled
My upper and bottom air diffuser was missing.
Purchased both air diffuser and placed it.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Orlando from FT LAUDERDALE, FL
Parts Used:
241537103, 215846604
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Freezer no freezing the food
Disconnect the power. To install the Defrost timer which is located inside the console at the top of the fridge I followed a YouTube video. It is very easy. Keep in mind that the Defrost timer comes settled in defrost mode so the compressor will not start after the power is reconnected.There is a hole in the console just behind the Defrost timer where you engaged it with a flat driver and rotate the clock until the compresor start. Now the compressor works for 6 hours and stop for 20 minutes for the defrosting cicle. The freezer now is freezing the meat!!
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Glen from HENDERSONVLLE, NC
Parts Used:
242077705, 5308000010
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
EVAPORATOR FAN MOTOR & BLADE
The service manual diagram shows the 149 complete fan shroud in a vertical (upright) position. Misleading! Of course.
The actual mounting of the lay in fan shroud fully assembled is in the horizontal position laying in a tray area just above the evaporator coil cage assembly. The entire shroud assembly can be installed incorrectly by the diagram and will still fit. BUT... no cold air will flow or be forced into the ice maker vent nor the refrigerator vent. I found this out the hard way by trial & error.
If the drawing had shown it in the horizontal position for both removal and reinstallation... it would have saved a lot of time and headaches. Also, the diagram does not show the (2) plastic angle supports on the shroud, another scratch your head event. Parts included on drawing... 149, 5, 8, 9, 13, 14 on CTFFHS2611PF4 diagram page of service manual.
ALSO, the (4) lower cabinet plate screws have to be removed, and the first left hand screw counting up to allow the next upper panel to swing out enough to lay the shroud in correctly (horizontal) on top of the evaporator coil cage. BOTTOM LINE... THE AIR FLOW HAS TO BE UP IN ORDER TO WORK PROPERLY.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Floyd from HONEY BROOK, PA
Parts Used:
215005101, 240530701
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Rail broke at the most support place
Took out top shelf, remove old screw and rail . Replace with new
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the FFHT1715LWA