Customer:
Robert from Arlington, TX
Parts Used:
242252702
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Replaced Water Inlet Valve
All instructions included on this site are good. I would add only one thing to them. When removing the 4 water lines from the old unit be sure to pull up on the white rings while you pull down on the water lines. All else is a snap.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Glen from Black River Falls, WI
Parts Used:
242252702
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
No Ice
I changed the valve but still no ice, changed the filter also. think it was just froze. could have saved me 70 bucks
Was this instruction helpful to you?
Thank you for voting!
Customer:
JAMES from ELLIJAY, GA
Parts Used:
242252702
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench (Adjustable)
No Water For Ice Maker Or Drinking
Repair as illustrated was right on. Repair was easy. No problem except still no water for ice or drinking. The valve was not the problem. Filter was replaced prior to valve replacement. Must be a electric switch some where. 3 Yrs ago I have replaced the water activation plastic lever for drinking which was a bit difficult and it turned out ok.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ray from Westland, MI
Parts Used:
242252702
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench set
leak at one of the valves in the back of refrigerator
Turned off the water supply ,pulled the plug removed two screws to access theater lines the new valve body was a little different than the original I had to cut off the end of each hose and push them in to the new connections the hoses are size and color coded replaced the two screws put the water line on plugged it in and turned on the water checked for leaks twice and replaced the back cover
Was this instruction helpful to you?
Thank you for voting!
Customer:
DOUG from SPRING, TX
Parts Used:
242252702
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Water Was Leaking From The Glass Fill Dispenser
This was probably the easiest repair I have done on this refrigerator. I pulled the unit away from the wall, turned off the water, and disconnected the hose. I have a wooden floor in my kitchen so I was careful to put a towel under the hose and valve. Very little water drained out but I kept the towel there for insurance. After removing the access panel, I removed the two screws holding the valve in place, slid it back to where I could unplug the wiring connected to it. The connectors are color coded so there is no worry about putting them back incorrectly. The new valve uses push-in type water connections, so you have to cut the old style connections off of the plastic water lines. Kitchen shears did this easily. Then is was just a matter of pushing each line into the proper connector on the valve, reattach the electrical connectors, and slide the valve back in place. Reinstall the screws, reinstall the access panel, hook up the water hose, slide the unit back into it's niche, and run about a gallon of water through the dispenser and you are done.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeffrey from Greenfield, MA
Parts Used:
242252702
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers, Wrench (Adjustable)
Water dripped from water dispenser after use
Pulled fridge away from wall and unplugged. Turned off main water supply feed and removed fitting from water inlet valve. Took off back panel by removing 3 screws. Took out 2 screws holding valve to fridge. Pulled off color coded wire clips. Unscrewed each water tube connector. New valve had quick connectors so had to snip off flared ends of tubing with utility knife. Pushed tubing firmly into new valve fittings and pulled to ensure connection. Reattached wiring and reattached valve to fridge with the 2 screws. Reconnected water feed line and turned on main water feed. Checked for leaks before replacing back panel. Done. No more dripping from water dispenser.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Fishkill, NY
Parts Used:
242252702
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Ice Maker stopped working
Realized Ice Maker was not getting water during it's cycle and suspected water valve based on other posts to this web site. My fridge is 9 years old and the tubes connecting the valve were plastic screw on type. The new valve did not have threads to accept the nuts. Turns out all I had to do was cut the nuts off and insert the water tubes into the valve which auto-locked the tubes to the valve. Ice maker now works great.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenny Keith from Terra Haute, IN
Parts Used:
242252702
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench (Adjustable)
Ice Maker/Water Solenoid Valve Assembly
Purchased a replacement part only to find the new part had push on fitting and my part has screw on fittings. Went to Youtube where Partselect had a video on how to replace the part from screw fittings to push on fittings
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles C. from Denver, CO
Parts Used:
242252702
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Quite making ice
The new inlet valve came with pisco connectors so had to cut the end of the tubes off. Before doing this I marked all the tubes to make sure they were replaced in the correct order. The pisco connectors are great to use and very quick. The total install time was about 20 to 30 minutes. While you have the back of the frig off make sure you vaccuum the fan and coils. It was making ice in less than 20 minutes.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from San Angelo, TX
Parts Used:
242252702
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Water leaking from dispenser
Used a nut driver to remove the small panal from the back of the refrigerator. Removed the two screws holding the valve in place. Unscrewed the water lines from the old valve and cut the ends off of them. Push the water lines back into the new valve. Unpluged the wiring from the old valve and installed them in the new valve. reinstalled the new valve and put the cover back on. Tested system for proper operation.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Katie from Hartville, MO
Parts Used:
241761301
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Moved it from FL to MO left bracket-upper hinge in FL
Used socket set and screw drivers to attach ordered hinge, thankfully we had the screws just not the hinge. Wonderful to be able to find and order on line! Thanks so much!!!
Was this instruction helpful to you?
Thank you for voting!
Customer:
JACK from OAK LAWN, IL
Parts Used:
242046001
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
unit was not cooling or freezing.
found the coil to be frozen like a block of ice. defrosted same, then looked up what defrost thermastat i needed and once it was received, i took the back of the freezer compartment off again, (two hex nuts, one on each end, and a small screwdriver to remove guard around fan. once this was removed, you then remove this panel, and you will see the evaperator coil, which will be frozen like a block of ice like i said. then remove defrost therm(small round piece with two wires connected to unit, disengage and re engage new thermostat. then put unit back!. no more freeze ups.also, therm was on top right of evaPERATOR. IT also snaps off on the bottom of thermastat. (just pull to or away from you and it should come off.
Was this instruction helpful to you?
Thank you for voting!
Customer:
WALTER R. from SHEFFIELD VILLAGE, OH
Parts Used:
242252702
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers, Wrench (Adjustable)
Leaking from refrigerator
Had a leak every night from refrigerator couldn't understand where from. Went on line and found some articles. I was referred to this sight by ads the articles and then in how to. I was pleased that a customer wrote their own instructions on what to do it was more concise clear and made preparation easier. First label towel cup and bucket needed too. Turn off water supply and electrical cord unplug then remove cover behind refrigerator vacuum and clean then. Water makes a mess so clean dry first. Then mark your hoses to remember order. Next remove old inlet and put in bucket it's pressure clamps so push in and it locks I chose to suction pipes and check for damage to pipes pin holes etc next I inserted into new inlet in order. At that time I turned water valve on checked for leaks at initial insert and new inlet. Next I plugged in unit cord. Waited. No leaks so far left for 30 minutes ran ice machine and water dispenser waited 20 minutes no leaks yet. Unplugged refrigerator unit. Installed the inlet completely to base and closed back paper panel after wiping water. Waited 24 hours then smiled no leak. Job done so far 2 weeks all clear. Hope this helps you will need screws driver and wrench for copper or main line I did find same part for less but this sight help me with good instructions the one they provide is for engineers architects lol not me I'm DYI
Was this instruction helpful to you?
Thank you for voting!
Customer:
Levern from Mc Donald, TN
Parts Used:
242252702
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
no water flowed to the ice maker
1. Turn off water in line to refrigerator. 2. disconnect hose from refrigerator. 3. Remove back cardboard panel at bottom of refrigerator. 4 Remove 2 screws holding in the valve assembly at bottom right. 5. best way I found to remove hoses (all color coded) is to cut with razor knife at the white collar. cut clean and square. 6. disconnect electrical (also color coded) 7. connect hoses to valve assembly by pushing hose firmly into hole. If you are familiar with PEX then this is the same. Reconnect electrical. Reconnect to refrigerator... 3,2,1 your done. It will take a couple cycles to get the air out of the lines.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mary from Mt Pleasant, PA
Parts Used:
242252702
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Wrench (Adjustable)
ice maker was not making ice, no water flow into.
watched the youtube video from PartsSelect and was able to remove old water inlet valve easily and install new one with little effort. The hoses on my refrigerator were a bit different than shown in video, but I was able to modify them and it's working just fine now. Thank you PartsSelect !
Was this instruction helpful to you?
Thank you for voting!