- Customer:
- David from Owensboro, KY
- Parts Used:
- 241734001
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
A 2" x 4" section on the bottom of the ice container bucket broke out.
Simply detached the old ice container by removing four screws and removing one screw holding the lever onto the bottom of the container. A bit of advice; make sure you note how the spring is attached to the lever before removing the screw. It took me a bit to determine how the spring activated the lever when I was reattaching it to the bottom of the container. Also, double check your order before you finalize it. I must have inadvertently hit the item twice so I received two of them. This resulted in me having to return one item and paying for extra shipping both ways. I received the part within two days of my order. It was a very fast turn-around. Also, when I realized that I received two parts and had to call to explain the situation, I found the person on the phone to be extremely helpful and courteous. She sent me information regarding how to return the product and didn't ridicule me once for my stupidity.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- gary from ARANSAS PASS, TX
- Parts Used:
- 5308000010
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Was this instruction helpful to you?
Thank you for voting!
Rust on Front Plate and Drive Blade
Downloaded a schematic of the ice container. Disassembled the ice container, keeping track of which different type of screws went where. Followed the schematic to ensure proper sequence of blades and spacers. Manually rotated unit prior to installing into the freezer in case of binding. Finished.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Micu from MOJAVE, CA
- Parts Used:
- 241798231
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Every thing went smooth
But I have back ground mechanical skills, I did see the video one time, and everything went smooth......
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from West Allis, WI
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
freezer defrost would melt the food
Looked up similar problems and found it to be the defrost timer. All I had to do was remove the plastic portion in the fridge section to get to the old timer. Popped the new one in and put it back together. Works great now. Would have been almost $150 to have a repair company come out and fix it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dante from SOUTHOLD, NY
- Parts Used:
- 241798231
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Ice Maker ffss2614qpo
Looked it up on how to, follow the video
. Very easy 1-2-3 it was out and new one in..........??.
. Very easy 1-2-3 it was out and new one in..........??.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Austell, GA
- Parts Used:
- 5304401778
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice despenser door would not close, frosting up in side, would not despense ice`
Removed outside cover on door despencer, (4 screws) unplug wire, removed unit from refrig and replace rusted thru wire that holds door shut. It was fairly easy. I actually took it apart twice, once for diagnosis and once for repair after the part arrived.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from New Carlisle, OH
- Parts Used:
- 5303288968
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Common drawer slide cracked
It was a snap. Literally. all I had to do was snap and slide the front off the broken drawer and slide and snap it onto the new.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- nathan from gillette, WY
- Parts Used:
- 5303918277
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
ice maker went bad
take the ice bin out of freezer. there are 2- 1/4" screws. these screws only need to be loosened a few turns. the ice maker can be slightly lifted up and will come off the screws. unhook the wire harness. take the "L" bracket off the old ice maker and put on the new one. set the new ice maker in. hook up the wire harness. put the new ice maker over the screws, tuck the wires out of the way and pull down into place. tighten the screws.
Was this instruction helpful to you?
Thank you for voting!
Easy Fix
Was really basic, simply slide off the old caps, slide on the new ones, put the shelf back where it goes, push down lightly so as to not snap the new caps, and viola, complete. No more than 2 minutes worth of work. Great part at a great price, shipping was more than the part itself so I bought 2 of each. Only problem I ran into was that I ordered the top shelf caps instead of the bottom the first time, so I had to reorder.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Les from Fenton, MO
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Freezer icing up and refrigerator section not cold
Removed four screws for cover on refrigerator temperature controls, unpluged old timer and pluged in new timer. Replaced cover and screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kyle from Porter, OK
- Parts Used:
- 5303917954
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Freezer coils kept freezing over.
1. Turned off the cooling cycle and unplugged the refrigerator.
2. Removed all of the shelving and bottom basket.
3. Removed rear covering in the freezer section.
4. If frosted over, manually defrost coils with hairdryer.
5. Located original thermostat and after marking the wire locations cut the wires and removed the Thermostat.
6. Connected matching wires using a lighter to melt the wires together. Wrapped repaired wires with electricians tape.
7. Unable to install the thermostat in the recommended location (freezer is a tight fit) the new part was installed at the original location.
8. Replaced the rear cover and shelves.
9. Plugged in the refrigerator and set the cycle back to cooling.
10. Monitored freezer coils couple of days/weeks depending on how fast they freeze over (slots at bottom of cover) to validate if problem solved.
2. Removed all of the shelving and bottom basket.
3. Removed rear covering in the freezer section.
4. If frosted over, manually defrost coils with hairdryer.
5. Located original thermostat and after marking the wire locations cut the wires and removed the Thermostat.
6. Connected matching wires using a lighter to melt the wires together. Wrapped repaired wires with electricians tape.
7. Unable to install the thermostat in the recommended location (freezer is a tight fit) the new part was installed at the original location.
8. Replaced the rear cover and shelves.
9. Plugged in the refrigerator and set the cycle back to cooling.
10. Monitored freezer coils couple of days/weeks depending on how fast they freeze over (slots at bottom of cover) to validate if problem solved.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alan from SAN MATEO, CA
- Parts Used:
- 316538904
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Repaired Oven Range Light Bulb
The bulb has a plastic clear cover. That cover can just be carefully removed using a screwdriver. It's held in by a metal bracket. After you remove the cover. You'll just need to replace the bulb and then re-install the cover and bracket.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Terry from KEYSTONE, IN
- Parts Used:
- 5303918277
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice maker leaking, then would'nt shut off.
Ice maker is held by 2 screws just above the unit, on the wall of the refrigerator. You can't see the screws, so borrow your wife's makeup mirror. Shine a light into the refrigerator, and using the mirror, locate the two screws, holding the unit in place, on the wall of the refrigerator. Using a nut driver, or socket wrench, with a 1/4 in socket, loosen up the two screws, but don't remove them. Bump the unit upwards, and away from the screws. (BEFORE doing anything!! Shut off the water supply, unplug the refrigerator) When you get the unit freed up, just unplug the old unit, and install the new one. You don't even have to worry about the water lines, and you'll see why, when you get the old unit off. Just reverse the procedure, installing the new unit. Very Simple, 10 to 15 minutes tops.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Henry D from PETERSTOWN, WV
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
sometimes it would go into defrost and would not go back to cooling.
I called the repairman who diagnosed the problem as a thermostat then had to order a thermostat took about 2 weeks to get back and install (cost little over $100). did good for about two weeks and same problem reoccured. I decided it was defrost timer and ordered from this site for $19.95 including shipping. I got on ( you tube ) and got instructions(recommend you tube) for DIY install about 15 to 20 minutes. Has been running great for about 3 weeks. ( YOU TUBE IS GREAT FOR A DIY REPAIR ON ABOUT ANYTHING)
Was this instruction helpful to you?