Jordan from Maumee, OH
Parts Used:
5308000010, 5300158289
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
Noisy fan
1. Removed the 7 nuts using the nut driver from the freezer back panel inside the freezer.
2. Remove the back panel. The evaporator motor and fan are located above the coils.
3. Unplug the wiring harness.
4. Remove the two gold mounting screws holding the motor and fan in place.
5. Remove the motor and fan including the brackets.
6. Install the new motor and fan onto the mounting bracket.
6a. Attach the green ground to the mounting bracket.
7. Screw the two gold screws back into the freezer.
8. Attach the new wiring harness. Note, the old harness had a mounting hole/space for it to connect to the wiring harness of the freezer. The new motor's harness was not long enough for this, so it is connected freely to the freezer harness.
9. Use the hair dryer to melt any ice that may have formed on the coils and hole where the fan goes.
10. Turn the freezer on to see if the fan turns on.
11. Reinstall the back panel.
All done!
152 of 178 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Alexandria, VA
Parts Used:
218906802
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light socket melted around bulb
After unsuccessfully trying to change the blown light bulb I discovered that the plastic light socket had gotten so hot that it melted and permanently fused with the blown bulb. After my new socket arrived in the mail I just popped the temp control assembly out with a screw driver and removed the old socket and placed the new one in. Whole operation to 5 minutes.
65 of 107 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
ROY from PENSACOLA, FL
Parts Used:
5308000010, 5300158289
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers
The Evaporator Fan Burnt Up
The fan motor all but caught the inside of the freezer on fire . Had to remove then clean, and I mean clean the walls of the freezer . Then had to pry out the old fan without breaking anything . Replacement of new fan was quick and easy because all the parts that I needed were in the bag
28 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
FREDDIE from WHITAKERS, NC
Parts Used:
5303276514, 5303007173
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Freezer stopped freezing food.
I unplugged electrical cord to the freezer. I removed the cover to the relay and load protector. I labeled the wires and made a diagram on the proper placement of each wire going to the relay. I unplugged each wire and removed the relay. Then I removed the load protector. I installed the new load protector and new relay. I placed the wires on the proper terminals of the relay. I replaced the electrical cover to the relay and load protector. I plugged the electrical cord back in the electrical outlet. My freezer started working again. I placed several bottles of water in the freezer to make sure the freezer was working properly before I restocked it with food.

Thanks again for the help. You just saved me about $400.
19 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Springfield,, TN
Parts Used:
5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Fan Noise
took cover off inside freezer control . removed old fan and unpluged wire harness plugged new one up and fastened back in place and put control cover back on.
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
alonso from Compton, CA
Parts Used:
5300158289
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Wrench (Adjustable)
Freezer starter acumulating lots of ice and the lower part of fridge was not cooling at all.
just took the back cover of the freezer of and then the fan. To do this, I just removed like four bolts at the corners and then four bolts that attached the fan to the cover. At the end, I just unplugged the cables. I got my new fan the very next day, which was like extremly fast, plug in the cables and attached the fan to the cover and then attached the cover to the original place. It's a pretty simple repair. My fridge is now working like it should be.
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Stephen from Bloomfield, NJ
Parts Used:
5300158289
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
the evaporator fan stopped working
I removed the plastic cowl in the rear of the freezer to gain access to the fan, took out two screws that secured the brackets holding the fan. Then I separated the coupling wires which had a sort of locking mechanism that was simple to undue. I took out the brackets along with the fan, separated the brackets and removed the screw for the ground wire. Then I simply reversed the process.
8 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dale from Fort Myers, FL
Parts Used:
5300158289
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Thought the evaporator fan was the issue
Did the obvious. Removed the stick-out cover, then the back of the freezer wall, after taking the bad evaporator fan out. Replaced the old motor with the new one, stuck the fan blades back on, and put the replacement back in place. Checked to see that the new motor and fan, before final hook up, had no issues. That was a success. However, when I put the parts in place, I had some significant vibrations. By taking things apart and re-doing the install, the vibrations went away. However, the final install, even if quiet, did not work. Apparently the condenser was kaput. No cooling after all the adjustments. We gave up and are replacing the fridge.
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Norman, OK
Parts Used:
5300158289
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
fan motor worn out
Removed the old and installed the new. Electrical plug/socket made connection easy. Biggest problem is working space in freezer side of a side by side with the fan in the back. If I can do it anyone can.
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Darrell from Bentley, ND
Parts Used:
5300158289
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
the evaporator fan quit when we had a power surge
A screw driver was used to remove two screws that held the old fan in place the new fan ws installed exactly where the old one came out and presto the job was complete. No major deal.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from BASKING RIDGE, NJ
Parts Used:
215846604
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Refrigerator had not been cooling
Discovered the coil was covered with 1/2 inch of ice because defrost cycle had not been working. Replacing the defrost timer and melting ice with hair dryer fixed problem. Hooray!
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Partlow, VA
Parts Used:
5300158289
Difficulty Level:
Very Difficult
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Motor squeal
I didn’t do the repair because the new motor had a female pigtail connector while the original motor has male connection. It came with wire clamps but didn’t want to cut wires to make repair. The pictures online show a male connection. Put the old motor back in and now it works fine.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
gary from ARANSAS PASS, TX
Parts Used:
5308000010
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerry from PHOENIX, AZ
Parts Used:
5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Freezer was freezing but refridgerator was warm. Checked fan and it was not turning.
Unplug fridge. Removed 2 nuts to get the vent plate off and two more nuts to get the motor mount off. Removed fan blade and then the fan motor. I put the new motor in and put everything back as it was. It was very easy. I had items in the freezer, so I didn't turn the fridge off other than to replace the part. It took about 6 hours for the fridge to reach optional temps because I didn't get to defrost and the fridge had to work it out on it's own. If you don't need the freezer then you should turn the refridgerator off for at least an hour and open the doors so the coils can defrost and any ice blockage between the freezer and fridge portion can melt away as well.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
earl a from GIRDLER, KY
Parts Used:
218906802
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
light blub blew
unplug power from ref removed old light socket only difference wired a little different checked new socket compaired to old checked terminal ends small big looked at wires big,little plugged up put in new light blub plugged ref power back on work power off pushed socket bac in power on works
4 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!