- Customer:
- Jim from Coulee City, WA
- Parts Used:
- 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
the fridge was freezing all the food.
I watched the video you had on-line and it was simple. Thank you so much
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- jose from brownsville, TX
- Parts Used:
- 5303917954, 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
The bottom part of the Refrigarater was warm
we removed the food from the freezer, disconnected the fridge , removed the cover, the evaporater fan was running, condeser fan was running, then we checked heater with multimeter and it was ok. next step we replaced the frostimer, and defrost thermostat . and then the refrigarater was working ok, problm was the frost thermastat damaged.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from Goldsboro, NC
- Parts Used:
- 5303917590
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Wrench set
Deforst Drain Pan rusted out
The old drain pan had a 1 ½” tall bushing attached to the center of the pan. The new pan did not have this bushing which was great. I had to cut about 1 inch off the bushing to remove the old pan. Also after cutting the bushing I had to screw the bushing off after cutting the old pan from the bushing. I installed new pan onto the ½” of threads that was left on the top of the compressor. Checked repair two days later all was great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronnie from Abbott, TX
- Parts Used:
- 5317842502
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Freezer was freezing up and would run all the time and not cycle off.
Unplug the refrigerator. You will ultimately need to remove the back panel of the freezer. But first, you will need to unscrew 2 screws on a small vertical fan vent and unscrew two screws on the fan. Maneuver the fan out of the round hole in the back panel and unplug the 3 prong wire connection. Then remove the fan. Unscrew the 4 remaining visible screwson the back pannel and remove the panel. This will expose the freon coils. On this model, the heater has two connections at the top of the coils. Unplug those wire connections. The heater extends down each side of the coils and along the bottom of the coils. Unhook two aluminum ties that connect the heater element to the coils. These ties stabilize the heater element and also prevents any current from flowing along the element because of the touching of two different metalic parts. Maneuver the heater element out of the coils. To install the new heater, reverse the above process beginning with installing the new heater element. If it hasn't already been done, it is good idea to test the old heater element with an ohm meter to make sure that the element is actually bad. The circuit should be open. This is the second heater element that I had to replace on this refrigerator, and it was actually burned in half both times, so I knew for sure the element was bad. Then test the new element to make sure it is good, and start the installation..
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Amarillo, TX
- Parts Used:
- 5303917954, 215846602
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers
The evaporator in the freezer unit was not defrosting
According to the information from the parts select website the thermostat and the defrost timer where ranked number 1&2 as likely to fail and cause the condition experienced. To replace the Defrost thermostat just remove the freezer bins and the lower panel covering the evaporator. Remove the old thermostat, measure the wire lengths and install the provided crimp splices. Note: the heat shrink tubing is WAY over-sized and will not shrink to the size needed. You will need another means of sealing the wire connection. Install the thermostat and replace the panel and shelves. The timer is real easy. On my model it is located under the freezer door under the kick panel on the front. Simply remove 2 Phillips head screws, unplug the old unit and install the new one. Be sure to cycle the thermostat past the defrost cycle on the timer (rotate until an audible click is heard once for the beginning of the cycle and one at the end) so that the unit will start up when power is reconnected. This resolved my problem and the unit is working great!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- STEVE from ROEBUCK SPRINGS, AL
- Parts Used:
- 5303917954, 215846602
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Frost Free Freezer Would Ice Up On Back Wall, And Fridge Would Be Warm
One of the three top comments from other replys had similar problems, so I took their advice, since the prices were resonable, I went and replaced two parts instead of just the defrost timer. If I had to do it a second time I could probably do it all in about 20 mins.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- wayne from marietta, GA
- Parts Used:
- 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
fridge not blowing cold
bottom left cornerof fridge defrost timer replaced two bolts and a wire
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Barbara from Marcellus, NY
- Parts Used:
- 5303200810
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Failure of temperature control
Unplugged refrigerator. Removed control knob and cover. Unwired control and removed same. Removed plastic tube from old capillary tube and placed on new unit. Installed and wired in new unit, making sure new unit was in the "off" position. Plugged in refrigerator, turned control knob to the first numerical setting, and was rewarded with the startup of the refrigerator compressor. Voila!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mainul from Portland, OR
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The refrigerator part was not cooling enough
I watched the video online where it described the troubleshooting tips for this type of symptom. So I knew exactly what the problem was which is the defrost timer. After the part came in I just unscrewed (4 screws) the box which houses the thermostat and the defrost timer from top ceiling of the refrigerator section. Then I just unscrewed and unhooked the old defrost timer and replaced it with the new one. After finishing the installation I turned the fridge on. At first nothing happened. So I turned the dial on the defrost timer with a flathead screw until it clicked and the fridge came alive. I waited for an hour or so. The cooling cycle completed and the fridge stopped as expected. When I opened the door I noticed the interior is much colder than before and right after closing the door the fridge hummed back into life again. So I know my fridge is working again. Thanks to PartSelect for providing the right part for my refrigerator. I will definitely buy from them again if anything goes wrong.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Long Beach, CA
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Freezer wouldn't go in to defrost cycle
After some troubleshooting to ensure the thermostat and heating element were working, determined that the defrost timer was the problem. With the defective part, I was able to manually advance the timer to activate the defrost cycle, but it wouldn't do so on its own. Unplugged the refrigerator from the wall. Timer is located in the refrigerator compartment at the very top. The compartment houses the cooling thermostat, the light bulb and the defrost timer. Using 1/4" nut driver, remove 4 screws holding compartment cover to top of fridge. Lower a bit to access electrical wiring. Wiring harness can be unplugged to work on the timer away from the fridge which makes it a bit easier. Timer is mounted with 2 phillips head screws. Remove screws and unplug timer from wiring. Install new timer, plug in wiring, secure with the phillips head screws and remount entire compartment.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- BILL from GENOA, WV
- Parts Used:
- 5303917954
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Refrig unit was frosting up top and bottom, did not properly defrost and stop cooling especially in lower compartment.
Unplug the refrigerator unit from wall. I removed freezer rack, plastic light cover, the ice rack shelf on the right side, then removed the plastic back cover panel, (4) retaining screws, gently tilting the panel toward me, unplug the wiring harness by depressing the clips on the side of the plug, removed panel from unit, set aside. If the unit was froze up, so I defrosted the cooling coils carefully with a common hair dryer until it was thawed. Be careful not to touch or bend the coils , since they are very fragile and SHARP! I located the old thermostat unit attached to a straight length of coolant line. The new unit looked like the old one, so it was easy to locate. I cut the two wires of the old unit close to the round base to make sure I would have enough wire to reconnect. Since my new unit did not indicate a polarity(Neg or Pos), I just wired each wire I cut to one of the new unit. I used the shrink tubing provided and heated the shrink till it was fully melted. I double ck'd to see if the wires were basically waterproof and a good connect. Also, before I replaced the rear panel, I made sure that both wires I had spliced had a drip loop to it so water would not drip down into the newly spliced union. Also made sure the wires will not interfere with the colling fan on the back of the rear panel. Reverse the procedure in reassembling. Plug in unit, and wait and listen for the unit coming back on..I kept a regular thermometer in the upper and lower compartments. Allow 24 hrs. for the unit to return to normal operation. It may defrost several times till the whole operation is back in sync.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ed from Memphis, TN
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Unit keep cutting off
Ordered the new part-Unplugged the refrigerator - took off the cover over the defective timer - put in the new part put the cover back on - plugged the refrigerator back in - so far, so good!~
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bertha from Lakewood, CA
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Refrigerator warm and freezer defrosting too quickly.
1. Disconnected electrical. 2. Removed upper console in refrigerator by removing 2 nuts. 3. Disconnected wiring from console. 4. Removed 2 screws from defroster timer part and pulled off from connector. 5. Replaced with new defroster timer and put everything back together. Thank you Steve for the U-Tube step by step video.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- hugh from delray beach, FL
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Frig did not run
Simply replaced the defrost timer located inside the frig just behind the temp dial. Very easy job. Removed the 3 screws holding the temp sw and light assembly. Removed the defrost timer w/ 2 screws and put i all back together. 15 mins at most. Suggest you watch the install video for pointers.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- gustavo from gilroy, CA
- Parts Used:
- 5300158289
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
Fridge was warm and no cold air was coming in
The repair was straightfoward. The evaporator motor I received from partselect was a different model with different wiring configurations. I cut the wires from the new motor per the instructions I received with the new motor and I did the same with the wires that connect to the fridge. Once I matched the wires and secured them with electrical caps I began to put the evaporator motor to the base and started screwing the screws the way I took them off. Once I connected the wire harness to the back of the freezer and turned it on I noticed a big difference in air flow. I was surprised at how easy it was to fix my refrigirator problem. It's been a few weeks now and the fridge is cold and working like it should. Don't be afraid of this task. it's very easy and will save you a ton of money. Thanks partselect.
Was this instruction helpful to you?
Thank you for voting!