Models > GLRH1779GW0 > Instructions

GLRH1779GW0 Frigidaire Refrigerator - Instructions

Jump to:

All Instructions for the GLRH1779GW0
16 - 30 of 53
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Marsha from BEVERLY, MA
Parts Used:
5304518034
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Wrench set
Refigerator Not Staying Cold
Bought the defrost timer based on PartSelect recommendations, installed it and no change. Apparently the old one was fine but since the refrigerator was in a flood and this part got submerged in water I kept it rather than returning it. I looked at everything closely and realized all the mechanical functions were working properly. Rarely does a condenser coil fail so I decided to look into recharging the coolant. Bought a 1/4 inch bullet valve, a 12oz. can of R-134a and a cheap resealable can adapter with hose, gauge and R22 to R-134a adapters. After a $30. investment Bingo, after one squirt the refrigerator began to cool and after 4oz. it now works better than new. I understand that PartSelect is in the business of selling only their parts but please consider that there can be other simple problems.
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeanne from SAN ANTONIO, TX
Parts Used:
5304518034
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer was running too warm
Removed the old defrost timer by removing 4 screws on the holding bracket. Disconnected the wire harness. Reconnected the wire harness to the new part. Installed the new part with 2 screws on the top of the molded bracket. I am a 67 year old woman... easy-peasy. (the defost timer is located in the bottom left rear of the freezer.
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bruce from MARTINEZ, CA
Parts Used:
5308000010
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Fridge made a hellacious noise and wasn't cooling well
From discussions with friends, I determined the problem might be easy to fix. The fridge made a lot of noise, but the compressor DID come on, and inside the freezer was cold, but the main fridge was warming.

After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to uncouple.

I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.

I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
gary from ARANSAS PASS, TX
Parts Used:
5308000010
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Warren, MA
Parts Used:
5304507200
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
frost and ice build up/ gasket wasnt sealing properly
I did watch a repair a utube video which I asked for when ordering. Pretty much followed most of the directions but:

started in left corner an lossed all screws from left to right. took off old gasket in small sections and inserted the new gasket and semi tighten screws

proceeded down left side then right little by little as above. to get to bottom of door.

bottom corners were a little snug to get them into place. the last corner was snug but once connected. tighten screws not too tight. You dont want to strip them.

test door with piece of paper.

if paper is not a snug tug, you can adjust gasket with a hair dryer set to low.

it was easy. freezer is all set.

Partselect was great to deal with, support verified the part number was correct for my freezer and help with that video.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
DAVE from LOS RANCHOS, NM
Parts Used:
5304518034
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Defrost Timer
The old defrost timer started making a screeching noise (probably bearings going out). The replacement part was a cinch to install. When I initially spoke to a PartsSelect person, they said the part number I gave them was not consistent with my old '94 Tappan Freezer. They were able to still find the proper replacement part number. The video that was on-line helpful also.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mike from Jacksonville, FL
Parts Used:
297217900, 5303305677
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers
Copper lines leaking freon
Removed the inside evaporator coil to do inside solder job, use torch to heat solder joints on the outside drier in order to remove it and install new drier. Soldered Heat exchanger line to drier and 1/4” copper line to compressor. Wrapped with new insulation wrap. Pulled a vacuum on system and then charged with 4.4 ounces of 134a freon. Works like a champ again!
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jack from WALLING, TN
Parts Used:
241639502
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
Fridge started making a loud racket. Condenser Fan Blade then disintegrated to dust and pieces. The plastic had degraded significantly.
The repair itself total time was quick and easy. Since the original fan blade blew apart, it was only a matter of putting the new one on in it's place. This can be done by feeding the blade between the cowling and Condenser coil and applying pressure to get it on the shaft.

If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.

In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.

Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.

Hope this helps someone. :)
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
CONSTANCE from NEW COLUMBIA, PA
Parts Used:
5304507200
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Door alarm going off indicating door ajar
This did not fix the problem. Call a repairman and he cannot come until 9/11. Food is staying frozen. Alarm sounds for awhile and then shuts off for a bit.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from GRANBURY, TX
Parts Used:
5304518034
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer not cooling due to icing up of coil.
The timer in this older unit is clearly exposed at the back of the freezer underneath the freezer compartment. It is attached with two Phillips head screws. After the screws are removed, the timer can be unplugged and the new one plugged in. The new timer has an extra flange to allow it to be used on more than one model of freezer. In order to mount the timer in this unit, you have to remove the extra flange by carefully cutting it away from the timer body, in similar fashion to what's depicted in the online video. This will allow you to mount the new timer to the mounting plate using the two screws from the old timer.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Stirling from FORT WORTH, TX
Parts Used:
5304518034
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Coils were freezing up. Defrost cycle not working
First unplug freezer, then disconnected wires from timer.
Removed 2 screws from bracket holding time to freezer.
Attached New part with screws. .The mounting bracket is now part of New time. Reattach wires.
I let coils defrost and then plugged it.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chris from Lockport, NY
Parts Used:
241639502
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
One blade broke from condenser fan
The part i recieved, from parts select was a larger in circumfrence (<1/4) than the original. However i was not aware of this until after i treid to repair it.

I removed the broken fan from the condenser. This was very sipmle.

When i pluged the refridgerator back in to the outlet the fan tried to start up but soon began to make aloud noise, due to there not being enough clerance.
11 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
W Howard from KEENE, NH
Parts Used:
240396102
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Old part broke
The original part broke. The plastic attachment end of the part snapped off. The new part was easy to attach.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Randolph from Edwards, MS
Parts Used:
297309000
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Evaporator fan not working
Took off cover, unplugged wires, removed old motor, mounted new motor, remounted new motor and replaced cover.

Now need a new control board for same model.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Paulden, AZ
Parts Used:
297036907
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Replace air filter light was on not on know
Easy
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GLRH1779GW0