Models > FPCE24VWPW1 > Instructions

FPCE24VWPW1 Frigidaire Refrigerator - Instructions

Jump to:

All Instructions for the FPCE24VWPW1
76 - 90 of 173
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Robert from HELENA, AL
Parts Used:
218906802
Difficulty Level:
A Bit Difficult
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Getting the light socket to snap back in properly
It snapped in place.
1 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Stuart, FL
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
coil Iceing up
took 4 screws out of the discharge vent on top of the refrigerator section and unpluged the wiring harness and put the section on the counter and unscrewed the timer and put the new one in and reinstalled the assembly and plugged the Jack and put the 4 screws back in, and rotated the timer and put it on defrost removed the back and check the heaters and drain .
0 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from Tullahoma, TN
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer and main compartment had wide temperature variations
I first thought the defroster heater broke - took the back wall of the freezer off and cooling fins were fine. Then took the defroster timer out and opened it up. The contacts were badly burnt so the compressor and fan ran during only part of the cooling cycle. Replacing the timer took less than 5 minutes - turn off the power, remove one screw to take out the control box, cut the ground wire (new timer housing is plastic and does not have a ground connection), remove two screws to unmount the timer, unplug the old timer, plug in the new timer, fasten with two screws, put the control unit in and fasten with one screw, turn power back on.
Was this instruction helpful to you?
Thank you for voting!
Customer:
BILL from GENOA, WV
Parts Used:
5303917954
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Refrig unit was frosting up top and bottom, did not properly defrost and stop cooling especially in lower compartment.
Unplug the refrigerator unit from wall. I removed freezer rack, plastic light cover, the ice rack shelf on the right side, then removed the plastic back cover panel, (4) retaining screws, gently tilting the panel toward me, unplug the wiring harness by depressing the clips on the side of the plug, removed panel from unit, set aside. If the unit was froze up, so I defrosted the cooling coils carefully with a common hair dryer until it was thawed. Be careful not to touch or bend the coils , since they are very fragile and SHARP! I located the old thermostat unit attached to a straight length of coolant line. The new unit looked like the old one, so it was easy to locate. I cut the two wires of the old unit close to the round base to make sure I would have enough wire to reconnect. Since my new unit did not indicate a polarity(Neg or Pos), I just wired each wire I cut to one of the new unit. I used the shrink tubing provided and heated the shrink till it was fully melted. I double ck'd to see if the wires were basically waterproof and a good connect. Also, before I replaced the rear panel, I made sure that both wires I had spliced had a drip loop to it so water would not drip down into the newly spliced union. Also made sure the wires will not interfere with the colling fan on the back of the rear panel. Reverse the procedure in reassembling. Plug in unit, and wait and listen for the unit coming back on..I kept a regular thermometer in the upper and lower compartments. Allow 24 hrs. for the unit to return to normal operation. It may defrost several times till the whole operation is back in sync.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dana from Bloomington, IN
Parts Used:
5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Fan Motor Noisy
Emptied freezer, removed fan motor cover (2 screws), removed fan and motor (2 screws), removed old motor from bracket and reassembled with new motor, transferred fan blade from old motor to new), re-installed new fan/motor (2 screws) and reinstalled cover...
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donald from Round Rock, TX
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Weird Noise that continued for at least 60 seconds control OFF.
Unplug the refrigerator. Removed the right hand top shelf. Used a 1/4" nutdriver to remove rear center mounting screw for Control Housing. Used Phillips screwdriver to remove two mounting screws for timer. Unplug cable from timer and plug it into the new timer. Install the new timer and re-install the Control Housing. Plug in the refrigerator and adjust the timer to start the unit. This was a snap with the diagnostic provided by Part Select. At first I thought it was the fan rubbing but when I removed the cover (two screws) it was obvious that wasn't the problem. The diagnostic hinted that it was either the timer or the motor capacitor making the noise. Because the noise continued after turning OFF the control, I thought it was the timer...I was right.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Susan from Rapid City, SD
Parts Used:
218906802, 316538904
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
My Frig Light Stopped
I am a 65 year old woman with no mechanical aptitude: I just unplugged the frig. And used a screw driver to pry of the plastic socket from its outside edge. . Then you just unplug two tiny contact plugs that appear when you pull out the socket and replug in those two the same way on the new part. Pop the socket back into the hole . . . . And screw in the new bulb. I knew I needed the socket part cause when the bulb burned out , a new bulb still did not work. . . If I can do it, anyone can!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Armando from Eagle pass, TX
Parts Used:
5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
the evaporator fan same time won't stater
change the evaporator fan motor kit working perfect
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donald from Waynesburg, PA
Parts Used:
5300158289
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Fan Motor Malfunction
Followed the instruction video. Removed the old one. Attached the fan blade, ground wire and connected power plug. Reinstalled with 2 screws. Works great.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ed from Memphis, TN
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Unit keep cutting off
Ordered the new part-Unplugged the refrigerator - took off the cover over the defective timer - put in the new part put the cover back on - plugged the refrigerator back in - so far, so good!~
Was this instruction helpful to you?
Thank you for voting!
Customer:
mark from murrieta, CA
Parts Used:
5303917954
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
the freezer coils were not defrosting so they would ice up and cut off the cold air into the refrigerator side
there were three possible problems the timer, the thermostat, or the heating element.i replaced the timer first as that is the problem 65% of the time and that did not fix the problem, i replaced the thermostat and that did fix the problem. after watching the video on line from parts select i took the back off of the freezer from the inside, defrosted the coils with a hair blower and then swapped out the thermostat which pops right off and i spliced the old connectors to the new thermostat. the heat shrink tubing that came with the part was a little to big so i put a smaller peice on each side for water proofing. that is what the cigarette lighter is for to supply heat to the heat shrink tubing.now that i have fixed that problem i may tackle the ice maker next
Was this instruction helpful to you?
Thank you for voting!
Customer:
Roger from Owatonna, MN
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
It would freeze up or not cool at all, depended where the clock stopped.
Removed the lower trim panel from front of fridg. and loosened two screws enough to turn it about 1/4 inch so the screw heads were in the larger holes. Pulled it out disconnected the wire connector and transfered the heat shield and screws to the new clock, connected the wire connector and aligned the screws. tightened them and job done. Has worked like new sense. Thanks Roger
Was this instruction helpful to you?
Thank you for voting!
Customer:
Guillermo from Miami, FL
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Freezer iced up, fridge section warm
After reading other posts, I decided to change the defrost thermostat, so I watched the videos, and did that. It got better, but the problem persisted, and the ice was still building up in the freezer section. So I decided that the problem was with the defrost heater. I ordered a new one, that was here under 24hs (using the Fedex ground). I replaced it, measured the old one and saw that it was not passing any current at all (so it was really burnt). Now the fridge is good as new, maintaining the proper temperatures both at Freezer and Fridge sections. Thank you Parts Select ! With $ 70 in parts I was able to get back my appliance working !!!
Was this instruction helpful to you?
Thank you for voting!
Customer:
K from Lakeview, MI
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
Refrigerator side not cooling (of Side by Side)
Turned off Refrigerator by thermostat switch in Freezer Compartment,(allowing for light to work in freezer). Then removed all food from freezer side,then all shelves & basket drawer. Next, unplugged refrigerator from electrical source. Removed back of inside of the freezer. Located the Thermostat for defrosting cooling coil. Removed and replaced with new part.(Tip-unplugged the wires for the original thermostat, remove from freezer and cut off and splice with connectors provided with new part, it's easier because you're not trying to do this in the narrow space of the freezer). Then attach the thermostat with new bracket and plug thermostat wires back in, replace back panel, shelves, plug in power supply, turn thermostat switch in Freezer to normal setting. Wait for Freezer to cool and replace food. It's currently working like new. BTW I thought I need a defrost time as well...however after I ordered that part and received it, I turned the existing defroster timer manually with a straight ended screwdriver very slowly and it cycled and the defrost rods glowed/functioned just fine. Therefore I didn't replace defrost timer. I'll save the new timer for future repair if needed. All in all it was fairly easy, and I didn't have to buy another fridge. I was really pleased with the service of this website...and the parts arrived very quickly via Fedex. Thanks www.partselect.com ! KJ
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sam from Marshall, NC
Parts Used:
5303917954
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver
freezer cold, fridge not cold
Removed shelving, and rear panels. Replaced condenser fan and defrost thermostat. Defrost coil ohmed fine. Reassembled and plugged in fridge with thermometers inside. Freezer at 22degrees and fridge at 32 degrees. My first time repairing a fridge. the partselect videos were very helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the FPCE24VWPW1