FRT22NRCD1 Frigidaire Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Wayne T from Galway, NY
- Parts Used:
- 5303917954
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Freezer was not defrosting thus refrigerator was not cooling
1. Unplug the refrigerator.2. Remove the storage rack and back panel in the freezer. 3. Locate the thermostat. 4. Defrost the freezer coils , i used a hair dryer. 5. Remove the thermostat from the cooling coil and then clip the connecting wires close to the unit. 6. Strip the ends of these wires and connect these wires to the wires of the replacement unit using the supplied wire connectors. 6. Heat seal with a lighter the connections using the water shield sleeves provided and further wrap connections with electrical tape. 7. Reconnect the thermostat to the cooling coil at the location it was removed from. 8. Replace the freezer back panel removed earlierand the storage rack if you have one. 9. Plug the freezer back in. My refrigerator has been working ever since the repair. There are several YouTube videos available that walk you through the diagnoses and repair process. They are very good.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronnie from Abbott, TX
- Parts Used:
- 5317842502
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Freezer was freezing up and would run all the time and not cycle off.
Unplug the refrigerator. You will ultimately need to remove the back panel of the freezer. But first, you will need to unscrew 2 screws on a small vertical fan vent and unscrew two screws on the fan. Maneuver the fan out of the round hole in the back panel and unplug the 3 prong wire connection. Then remove the fan. Unscrew the 4 remaining visible screwson the back pannel and remove the panel. This will expose the freon coils. On this model, the heater has two connections at the top of the coils. Unplug those wire connections. The heater extends down each side of the coils and along the bottom of the coils. Unhook two aluminum ties that connect the heater element to the coils. These ties stabilize the heater element and also prevents any current from flowing along the element because of the touching of two different metalic parts. Maneuver the heater element out of the coils. To install the new heater, reverse the above process beginning with installing the new heater element. If it hasn't already been done, it is good idea to test the old heater element with an ohm meter to make sure that the element is actually bad. The circuit should be open. This is the second heater element that I had to replace on this refrigerator, and it was actually burned in half both times, so I knew for sure the element was bad. Then test the new element to make sure it is good, and start the installation..
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- gustavo from gilroy, CA
- Parts Used:
- 5300158289
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
Fridge was warm and no cold air was coming in
The repair was straightfoward. The evaporator motor I received from partselect was a different model with different wiring configurations. I cut the wires from the new motor per the instructions I received with the new motor and I did the same with the wires that connect to the fridge. Once I matched the wires and secured them with electrical caps I began to put the evaporator motor to the base and started screwing the screws the way I took them off. Once I connected the wire harness to the back of the freezer and turned it on I noticed a big difference in air flow. I was surprised at how easy it was to fix my refrigirator problem. It's been a few weeks now and the fridge is cold and working like it should. Don't be afraid of this task. it's very easy and will save you a ton of money. Thanks partselect.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Curtis from Winlock, WA
- Parts Used:
- 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
won't start repaced the run capacitor didn't solve the problem so I ordered a defrost timer
I watched the videos (they really help) and followed the steps. Everything went smooth with no surprises
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- doug from Franklin, TX
- Parts Used:
- 5300158289
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
bottom of fridge quit cooling
dismantled the top rear panel of the freezer and found I had the wrong part. Hand started the fan motor and it has been working fine since.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from Hudson, FL
- Parts Used:
- 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
not cold enough
per the video..easy installation....unfortunately the temperature did not improve. We still have a refrigerator temp in the upper freezer.....and a "cooler" in the refrigerator section
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- FRANK from BRADENTON, FL
- Parts Used:
- 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Frige and freezer not cooling
I should have ordered start kit instead of start capacitor. The start cap astir did not fix problem so I ordered kit. Compasator comes as part of kit. Followed enclosed instructions. Cut existing wires and reconnected new wiring. Simple as that. It's a plug in item. Now worried it may be working to good. Freezer down to 10 deg. Watching to see if compressor is running to long. Seems ok lol. Wife hates me now. She wanted new frige.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from Glenmoore, PA
- Parts Used:
- 5300158289
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Refridgerator compartment warm but freezer frosty
First I replaced the defrost thermostat, then I realized that the evaporator fan would stop turning periodically. I could restart it by spinning the fan with my finger. The fan is behind a cover in the back of the freezer. If you remove the cover and check on the fan when you hear the condenser fan in the back running. (They seem to run at the same time.) It was easy to replace the fan and the new one is more powerful than the original. The refrigerator runs fine now. Thank you for this great site. Saved me a lot of $$.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Baltimore, MD
- Parts Used:
- 215095900
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Wrench set
hinge pin missing
replaced the hinge pin then put the doors on and was finish.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- wilson from indialantic, FL
- Parts Used:
- 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
compressor not running
thanks to all of the people who had the same problems I was able to make a quick fix on my fridge. I pulled the back cover off and found the compressor not kicking on so I replaced the start cap. and im back in bussiness.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bart from goldsboro, NC
- Parts Used:
- 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
the compressor capacitor overheated
it was great. I ordered the capacitor for my frigidaire frig and it arrived
in 3 days. plugged in the part to the compressor and my frig has been
working ever since. I spent 3 minutes ordering the part and 30 seconds
attaching it to the frig. Easy, very easy. saved myself a 75 dollar repair
visit. thanks
in 3 days. plugged in the part to the compressor and my frig has been
working ever since. I spent 3 minutes ordering the part and 30 seconds
attaching it to the frig. Easy, very easy. saved myself a 75 dollar repair
visit. thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- B from PEPPERELL, MA
- Parts Used:
- 5303288973
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Broken shelfe supporrt
real easy with the help of the video , made the difference
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- jerry from petaluma, CA
- Parts Used:
- 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
refer quit cooling and so did freezer
I replaced the defrost timer,defrost thermostat,and run cap.as it turned out the compressor went bad. I dont know the model because but the time I got this review I replaced the refer with a knew one . two weeks living out of coolers was so much fun !!!!!!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mike from Kilgore, TX
- Parts Used:
- 5304464438, 216008900
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
compressor wouldn't start
I used a pick to remove the lugs from the old starter. Clicked them right in the new one and it went to woking!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- BILL from GENOA, WV
- Parts Used:
- 5303917954
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Refrig unit was frosting up top and bottom, did not properly defrost and stop cooling especially in lower compartment.
Unplug the refrigerator unit from wall. I removed freezer rack, plastic light cover, the ice rack shelf on the right side, then removed the plastic back cover panel, (4) retaining screws, gently tilting the panel toward me, unplug the wiring harness by depressing the clips on the side of the plug, removed panel from unit, set aside. If the unit was froze up, so I defrosted the cooling coils carefully with a common hair dryer until it was thawed. Be careful not to touch or bend the coils , since they are very fragile and SHARP! I located the old thermostat unit attached to a straight length of coolant line. The new unit looked like the old one, so it was easy to locate. I cut the two wires of the old unit close to the round base to make sure I would have enough wire to reconnect. Since my new unit did not indicate a polarity(Neg or Pos), I just wired each wire I cut to one of the new unit. I used the shrink tubing provided and heated the shrink till it was fully melted. I double ck'd to see if the wires were basically waterproof and a good connect. Also, before I replaced the rear panel, I made sure that both wires I had spliced had a drip loop to it so water would not drip down into the newly spliced union. Also made sure the wires will not interfere with the colling fan on the back of the rear panel. Reverse the procedure in reassembling. Plug in unit, and wait and listen for the unit coming back on..I kept a regular thermometer in the upper and lower compartments. Allow 24 hrs. for the unit to return to normal operation. It may defrost several times till the whole operation is back in sync.
Was this instruction helpful to you?
Thank you for voting!