- Daniel from North Plains, OR
- Parts Used:
- 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Freezer & fridge warm / condenser coils iced over
Problem not consistent. OK for 2-3 weeks, then freeze coils. Mark and observe the defrost timers manual rotating adjuster. Timer would stop mid cycle. One revolution equals 8 hours of compressor run time followed by 30 minutes of defrost. Replacing timer took 5 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Terri Ann from Owensboro, KY
- Parts Used:
- 5303323481
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The shelf end cap had broken
I slid the new end cap onto the bar and snapped the bar back into place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- PAUL from WEIRTON, WV
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
freezer frosted up and air could not circulate to the food section, causing the temperature to get warm, 55 degrees
I followed the procedure online and found the thermostat was ok, it had continuity when cold, and the heater coil was also ok, it too had continuity, therefore the problem was a bad defrost timer. the refrigerator works great, thanks parts select!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dana from Bloomington, IN
- Parts Used:
- 5300158289
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Fan Motor Noisy
Emptied freezer, removed fan motor cover (2 screws), removed fan and motor (2 screws), removed old motor from bracket and reassembled with new motor, transferred fan blade from old motor to new), re-installed new fan/motor (2 screws) and reinstalled cover...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- BILL from GENOA, WV
- Parts Used:
- 5303917954
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Refrig unit was frosting up top and bottom, did not properly defrost and stop cooling especially in lower compartment.
Unplug the refrigerator unit from wall. I removed freezer rack, plastic light cover, the ice rack shelf on the right side, then removed the plastic back cover panel, (4) retaining screws, gently tilting the panel toward me, unplug the wiring harness by depressing the clips on the side of the plug, removed panel from unit, set aside. If the unit was froze up, so I defrosted the cooling coils carefully with a common hair dryer until it was thawed. Be careful not to touch or bend the coils , since they are very fragile and SHARP! I located the old thermostat unit attached to a straight length of coolant line. The new unit looked like the old one, so it was easy to locate. I cut the two wires of the old unit close to the round base to make sure I would have enough wire to reconnect. Since my new unit did not indicate a polarity(Neg or Pos), I just wired each wire I cut to one of the new unit. I used the shrink tubing provided and heated the shrink till it was fully melted. I double ck'd to see if the wires were basically waterproof and a good connect. Also, before I replaced the rear panel, I made sure that both wires I had spliced had a drip loop to it so water would not drip down into the newly spliced union. Also made sure the wires will not interfere with the colling fan on the back of the rear panel. Reverse the procedure in reassembling. Plug in unit, and wait and listen for the unit coming back on..I kept a regular thermometer in the upper and lower compartments. Allow 24 hrs. for the unit to return to normal operation. It may defrost several times till the whole operation is back in sync.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from Round Rock, TX
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Weird Noise that continued for at least 60 seconds control OFF.
Unplug the refrigerator. Removed the right hand top shelf. Used a 1/4" nutdriver to remove rear center mounting screw for Control Housing. Used Phillips screwdriver to remove two mounting screws for timer. Unplug cable from timer and plug it into the new timer. Install the new timer and re-install the Control Housing. Plug in the refrigerator and adjust the timer to start the unit. This was a snap with the diagnostic provided by Part Select. At first I thought it was the fan rubbing but when I removed the cover (two screws) it was obvious that wasn't the problem. The diagnostic hinted that it was either the timer or the motor capacitor making the noise. Because the noise continued after turning OFF the control, I thought it was the timer...I was right.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from Waynesburg, PA
- Parts Used:
- 5300158289
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Fan Motor Malfunction
Followed the instruction video. Removed the old one. Attached the fan blade, ground wire and connected power plug. Reinstalled with 2 screws. Works great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ed from Memphis, TN
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Unit keep cutting off
Ordered the new part-Unplugged the refrigerator - took off the cover over the defective timer - put in the new part put the cover back on - plugged the refrigerator back in - so far, so good!~
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Armando from Eagle pass, TX
- Parts Used:
- 5300158289
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
the evaporator fan same time won't stater
change the evaporator fan motor kit working perfect
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- mark from murrieta, CA
- Parts Used:
- 5303917954
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
the freezer coils were not defrosting so they would ice up and cut off the cold air into the refrigerator side
there were three possible problems the timer, the thermostat, or the heating element.i replaced the timer first as that is the problem 65% of the time and that did not fix the problem, i replaced the thermostat and that did fix the problem. after watching the video on line from parts select i took the back off of the freezer from the inside, defrosted the coils with a hair blower and then swapped out the thermostat which pops right off and i spliced the old connectors to the new thermostat. the heat shrink tubing that came with the part was a little to big so i put a smaller peice on each side for water proofing. that is what the cigarette lighter is for to supply heat to the heat shrink tubing.now that i have fixed that problem i may tackle the ice maker next
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roger from Owatonna, MN
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
It would freeze up or not cool at all, depended where the clock stopped.
Removed the lower trim panel from front of fridg. and loosened two screws enough to turn it about 1/4 inch so the screw heads were in the larger holes. Pulled it out disconnected the wire connector and transfered the heat shield and screws to the new clock, connected the wire connector and aligned the screws. tightened them and job done. Has worked like new sense. Thanks Roger
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Guillermo from Miami, FL
- Parts Used:
- 5303917954
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Freezer iced up, fridge section warm
After reading other posts, I decided to change the defrost thermostat, so I watched the videos, and did that. It got better, but the problem persisted, and the ice was still building up in the freezer section. So I decided that the problem was with the defrost heater. I ordered a new one, that was here under 24hs (using the Fedex ground). I replaced it, measured the old one and saw that it was not passing any current at all (so it was really burnt). Now the fridge is good as new, maintaining the proper temperatures both at Freezer and Fridge sections. Thank you Parts Select ! With $ 70 in parts I was able to get back my appliance working !!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jim from Coulee City, WA
- Parts Used:
- 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
the fridge was freezing all the food.
I watched the video you had on-line and it was simple. Thank you so much
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from Nineveh, IN
- Parts Used:
- 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Faulty defrost timer. Freezer would not maintain temperature
Watched the video once. Removed four 1/4 inch screws with a nut driver unplugged the unit, took out two screws securing the timer. Replaced did all of this in about 10 minutes. It was "exactly" as the video showed and it's worked perfectly since the replacement of the faulty timer. I saved a $75.00 service call minimum and the part was more than likely cheaper from Part Select than from the repair facility. Although I'm a pretty good handy man, you would not need any experience to make this repair. The instructions are precise and the part fit perfectly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Raymond from Yorktown Heights, NY
- Parts Used:
- 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator too Warm
tested the thermostat, cleaned the coils, checked seals all clean. defrost timer did not cycle so replaced it but issue not resolved. even though freezer was working while refrigerator was problematic, proceeded to open freezer panel. discovered that fan was not pushing cold air into refrigerator compartment due to ice build up in connecting tubes. cleaned ice and replaced panels to positive result
Was this instruction helpful to you?
Thank you for voting!