FPG19TPLW0 Frigidaire Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Ronald from Defiance, OH
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
leaking water down into fridge
just like the video showed...it was excellent!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephen from Strongsville, OH
- Parts Used:
- 5303325991, 5303325990
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
end cap hooks broke off cap
Put new end caps on door bar..put soap around door slots diped end caps in boiing water for 20-30 seconds and snapped in place
I HAVE SENT IN TWO STORIES I"M DONE OK
BUT THANKS FOR GREAT SERVICE
Thanks Steve 10-3-09
I HAVE SENT IN TWO STORIES I"M DONE OK
BUT THANKS FOR GREAT SERVICE
Thanks Steve 10-3-09
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jim from Decatur, GA
- Parts Used:
- 5303323480
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
front rack broke off
Slipped out the end caps with the broken prongs from the front rack and slipped in the new end caps. (3 mins.)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from HELENA, AL
- Parts Used:
- 218906802
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Getting the light socket to snap back in properly
It snapped in place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- BILL from GENOA, WV
- Parts Used:
- 5303917954
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Refrig unit was frosting up top and bottom, did not properly defrost and stop cooling especially in lower compartment.
Unplug the refrigerator unit from wall. I removed freezer rack, plastic light cover, the ice rack shelf on the right side, then removed the plastic back cover panel, (4) retaining screws, gently tilting the panel toward me, unplug the wiring harness by depressing the clips on the side of the plug, removed panel from unit, set aside. If the unit was froze up, so I defrosted the cooling coils carefully with a common hair dryer until it was thawed. Be careful not to touch or bend the coils , since they are very fragile and SHARP! I located the old thermostat unit attached to a straight length of coolant line. The new unit looked like the old one, so it was easy to locate. I cut the two wires of the old unit close to the round base to make sure I would have enough wire to reconnect. Since my new unit did not indicate a polarity(Neg or Pos), I just wired each wire I cut to one of the new unit. I used the shrink tubing provided and heated the shrink till it was fully melted. I double ck'd to see if the wires were basically waterproof and a good connect. Also, before I replaced the rear panel, I made sure that both wires I had spliced had a drip loop to it so water would not drip down into the newly spliced union. Also made sure the wires will not interfere with the colling fan on the back of the rear panel. Reverse the procedure in reassembling. Plug in unit, and wait and listen for the unit coming back on..I kept a regular thermometer in the upper and lower compartments. Allow 24 hrs. for the unit to return to normal operation. It may defrost several times till the whole operation is back in sync.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- daryl from n.las vegas, NV
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
frig side not cool/freezer coils not defrosting
unplugged frig,removed bottom front cover and loosend 2 screws at bottom front left and slid defrost timer out from behind metal panel,unplugged the old and plugged in the new.frig works great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael E from Uniontown, PA
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
freezer was freezing and no refrigerator
Followed instruction vedeo from partselect. THANKS!!!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- GERALD from NORTHPORT, MI
- Parts Used:
- 5303325991, 5303325990
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
broken caps
Snapped new caps in place . Took about 30 seconds!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from North Plains, OR
- Parts Used:
- 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Freezer & fridge warm / condenser coils iced over
Problem not consistent. OK for 2-3 weeks, then freeze coils. Mark and observe the defrost timers manual rotating adjuster. Timer would stop mid cycle. One revolution equals 8 hours of compressor run time followed by 30 minutes of defrost. Replacing timer took 5 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Terri Ann from Owensboro, KY
- Parts Used:
- 5303323481
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The shelf end cap had broken
I slid the new end cap onto the bar and snapped the bar back into place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christopher from Wilmington, DE
- Parts Used:
- 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Freezer was cold bit the refrigerator was warm.
Based on the diagnosis on this site I thought the 66% odds of the problem being the Defrost Timer looked pretty good, $30 including shipping versus a Sears tech phone estimate of $250-300. BINGO! Just follow the online installation instructions and don't forget to use the reset switch as described. Works like new! THANK YOU
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- PAUL from WEIRTON, WV
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
freezer frosted up and air could not circulate to the food section, causing the temperature to get warm, 55 degrees
I followed the procedure online and found the thermostat was ok, it had continuity when cold, and the heater coil was also ok, it too had continuity, therefore the problem was a bad defrost timer. the refrigerator works great, thanks parts select!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Diane from San Antonio, TX
- Parts Used:
- 5303325991, 5303325990
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The small tabs broke off in one of our many Miltary moves. For ten plus years I have not had the use of the door shelves.
This poor frig.(purchased in 1984) has gone thru five military moves. Somewhere along the line the plastic tabs to the door shelves broke, but I retained the metal bars. I hoped to find the required plastic ends to fix them and you had exactly what I needed. The repair was so fast and easy. The amount of pressure was a bit more than I originally thought was needed but they all went in perfectly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dean from Sunset, SC
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Freezer worked, Frig would not cool.
Unplugged the frig. Removed temp control module from frig, 1 screw with nut driver. Activated defrost timer by rotating adjustment until 2 clicks are heard. Removed two timer mounting screws, unpluged timer, plugged in the new timer, mounted it to the control module with 2 mounting screws. Replaced control module with the 1 mounting screw. Closed door and plugged it up.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- thomas from Chepachet, RI
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
at first auto defrost would not work so I had to take the frezer panel apart and defrost it with a hair dryer every ten days
pulled down the thermostat cover and unpluged the timer control and replaced it with the new part. total time to repair was about 15 min. there was a vidio on how to replace the new part that just informed me that I did it right!!!!very easy site to find what you are looking for!!!!
Was this instruction helpful to you?
Thank you for voting!