Amber from SHERMANS DALE, PA
Parts Used:
5303918774
Difficulty Level:
Very Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Socket set
Fan motor no longer functioning and needed to be replaced
The most difficult part was the removal of the existing fan and shroud. There is very little room to work between the condenser and the coils where the fan is located. The old shroud had to be removed as it was not compatible with the mounting for the new fan motor and blade. Make sure to unplug the refrigerator and give the coils some time to cool down. The first step was to remove the old fan blade... it simply pulls off. Next you need to remove the two bolts holding the fan shroud to the floor of the refrigerator. Then you need to remove the old fan motor from the shroud... unplug the wire connection and remove two small bolts that hold it on. I was lucky to have a VERY small ratchet to get into these tight spaces. Now is the really hard part, removing the metal fan shroud takes a lot of twisting and turning to get it out. The coils have a little play in them, but you must be very careful of the tubing and connections. Also, the coils are very sharp. Once this is out, IF you can get it out....I had my doubts along the way, you can start to put the new parts in... beginning with the new fan shroud which fortunately is made of plastic and has some give which makes it easier to get in. Then you can mount the new motor to the shroud with the three new screws. Plug in the wire connection, add the foam tape to the shroud and mount the shroud to the floor of the frig with the original two bolts. Lastly, attach the fan blade. This replacement kit is well constructed, fits perfectly and contained all the necessary parts (fan motor with wiring connection, mounting screws, wire connection adapter, fan shroud, foam tape and fan blade), but no detailed instructions come with it. I was lucky to get the old fan shroud out without doing any damage to the surrounding parts, but this part was very difficult for a do it yourself person. I would be interested to know if a professional has some other tips for this part of the replacement process.
12 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jim from Carlsbad, CA
Parts Used:
240338001
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Plastic Shelf Broke
Snapped in place in less than 30 seconds
11 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from SEQUIM, WA
Parts Used:
5304518034
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Freezer would not run; no electrical power to the compressor
Looking on-line at your diagnostic for this problem, I saw the most common part to cause this problem was the start capacitor, so I purchased one & installed it with no positive outcome. I then purchased the next recommended part which was a defrost timer & installed it with no run again. Frustrated, I looked at another diagnostic web site that claimed 90% of the time the problem is caused by the cold control thermostat. I tested mine and it tested bad, so I bought a control elsewhere, since your site did not list a PN for that device. I installed the new control and the freezer started up correctly. Looking at the wiring diagram for these parts, I see the start capacitor and defrost control are downstream of the cold control thermostat, and to my mind should have been the first part recommended for testing versus the parts I bought, so I am somewhat disappointed in the diagnostics on your site, where I spent about $80 for parts that were functional.
11 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mike from Los Banos, CA
Parts Used:
297309000
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Evap fan motor intermitant
Removed evap cover from Commercial Refrigerator. Removed mounting screws from Evap motor mount. Replaced evap fan motor. Repositioned. Reinstalled evap cover. Tested . This motor was hard to find locally. Glad I called.
11 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
TIM from Lockport, IL
Parts Used:
240524102
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
broken fan with vacumme cleaner
I remembered to unplug first. took the little cover off on the bottom, unscrewed the 3 screws. then just held the base that the fan is on and pulled rite off, pushed the other one rite on. it took me five min, i want to say thanks to parts select, had the part, fast shipping, great job, thank you.
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from Argyle, WI
Parts Used:
5304518034
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Freezer not defrosting
Replaced defrost thermostat and defrost timer on my commercial Kelvinator freezer. Took out screws inside freezer compartment that hold panel at top inside freezer.Once the screws were removed I pulled out the thermostat dial so the panel was free to drop down and expose coils to the freezer that were located in the top rear of the inside freezer compartment.The defrost thermostat was located on the top of the coil to the top left as you face the inside of the Kelvinator KFS220RHY1 freezer. Very easy unplug old and plug in new defrost thermostat. Also replaced timer located in the back side of the freezer down near the middle of the bottom of the freezer near the compressor. There were two nuts holding the timer in the back of the freezer once I took those out I just unplugged the old timer and plugged the new timer in ....very simple fix. I have only run my freezer for a week since I replaced both parts but so far all is working well.
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Letitia from OFallon, IL
Parts Used:
240338001
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Door Shelf Was borken held together by duck tape
I receive the part the next day eventhough I paid for 3-5 day delivery. It took lest than 10 seconds to snap into place and now it looks like new.
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jaime from Harrisburg, PA
Parts Used:
240530811
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Cracked drawer
I slid out the old drawer and slid in the new drawer. Easy as that! I would recommend this website to anyone.
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Venita from MENA, AR
Parts Used:
240524102
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Broken fan blade
Followed video instructions which were to unplug refrigerator, on lower back use screwdriver, loosen 4 screws, take off plastic cover, pull out fan, replace with new fan, replace cover and 4 holding screws, plug in refrigerator. I am female, 77 years old and if I can do it, anyone can.
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from McBee, SC
Parts Used:
5303918774
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
Freezer compartment warm / Ice cream soft
I worked for GM as a Frigidaire Tech, before starting my own business. I have retired now.
I took the three screws off the back of the bracket holding the motor. Disconected wire harness and pulled out the motor. Reverse to install. servantoftheking@hughes.net
9 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Walter from SALT LAKE CTY, UT
Parts Used:
297309000
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Squealing noise and bottom half of freezer only froze
I removed the shelves, unscrewed the cover panel of the fan motor and regulator dial, disconnected the fan motor from power, unscrewed 2 screws holding the motor to the mounting bracket and put the new motor in it's place. New motor had no thread in the mounting holes, so I put new tread in so I could use the 2 screws. Another option would have been to drill all the way through the mounting holes and use longer screws or bolts. Of course I turned the power off before I started repairs. Freezer runs like new now. Technicians wanted $400 for the job, while it cost me a mere $55 for the Motor.
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marsha from BEVERLY, MA
Parts Used:
5304518034
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Wrench set
Refigerator Not Staying Cold
Bought the defrost timer based on PartSelect recommendations, installed it and no change. Apparently the old one was fine but since the refrigerator was in a flood and this part got submerged in water I kept it rather than returning it. I looked at everything closely and realized all the mechanical functions were working properly. Rarely does a condenser coil fail so I decided to look into recharging the coolant. Bought a 1/4 inch bullet valve, a 12oz. can of R-134a and a cheap resealable can adapter with hose, gauge and R22 to R-134a adapters. After a $30. investment Bingo, after one squirt the refrigerator began to cool and after 4oz. it now works better than new. I understand that PartSelect is in the business of selling only their parts but please consider that there can be other simple problems.
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeanne from SAN ANTONIO, TX
Parts Used:
5304518034
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer was running too warm
Removed the old defrost timer by removing 4 screws on the holding bracket. Disconnected the wire harness. Reconnected the wire harness to the new part. Installed the new part with 2 screws on the top of the molded bracket. I am a 67 year old woman... easy-peasy. (the defost timer is located in the bottom left rear of the freezer.
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bruce from MARTINEZ, CA
Parts Used:
5308000010
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Fridge made a hellacious noise and wasn't cooling well
From discussions with friends, I determined the problem might be easy to fix. The fridge made a lot of noise, but the compressor DID come on, and inside the freezer was cold, but the main fridge was warming.

After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to uncouple.

I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.

I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Wendy from OCALA, FL
Parts Used:
240350608
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Broken Crisper Glass
Very easy. Watched a video on your site prior to getting the glass replacement. Removed the crisper drawers. Placed the glass in the front and placed it down. Took just a few minutes. Love your site and will come back again when needed. Thank-you.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the PLRU1777DS0
16 - 30 of 189