Ice make just stopped
I want to first say that before I ordered this part from "Part Select" I first went and talked with a local appliance repair shop. They quoted me a $120 charge to come out and check the problem. Then $30 and hour service fee, plus parts. He provided me a quote of about $250 for the job.
I found this part easily on the web site $77. It was very easy to instal. The only problem I had was the fact that in the side by side it was very difficult for me to get two hands inside the freezer to install it. (I have wide shoulders). Two screws loosened, no need to remove them. Just life the entire unit straight up. Unplug wire harness. Then just reverse order. Could not be easier. If you can change a light bulb you can do this.
I found this part easily on the web site $77. It was very easy to instal. The only problem I had was the fact that in the side by side it was very difficult for me to get two hands inside the freezer to install it. (I have wide shoulders). Two screws loosened, no need to remove them. Just life the entire unit straight up. Unplug wire harness. Then just reverse order. Could not be easier. If you can change a light bulb you can do this.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Alexandria, VA
- Parts Used:
- 5303918277
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Ice maker burned out
Removing the old unit was easy enough, just loosened two screws that attach unit to side of freezer and disconnected the wiring harness. But the new unit never goes in quite as easily because it's always just a little different from the original. In this case, the wiring ended up being about six inches longer and the excess had to be stuffed behind a shield at the rear of the unit. Theoretically, the wire could have been pushed back through the opening, but it got jammed and wouldn't go. I had to remove side rails and pry the shield forward in order to get the wiring back out of the way. The unit is a narrow side by side, so there wasn't a lot of room to move around. But it wasn't difficult, just tedious. I had to make sure the wiring did not come into contact with the heating element at the bottom of the icemaker. Once installed it worked great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from ORANGE, TX
- Parts Used:
- 241798231
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice maker quit working
Followed the steps in the video on your site, really easy to do.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Virginia Beach, VA
- Parts Used:
- 5304464438, 216008900
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
would not freeze
unplugged, removed old parts, replaced with new
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Vicki from Johnson City, TX
- Parts Used:
- 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Refrigerator was not cooling
This was a simple job. Raised the flap in the back that houses the compressor, removed the wire that holds the relay, pulled out the old relay and pushed the new one on. Replaced wire holder and that was it. Plugged it frig and freezer is at zero and lower compartment at 35. As easy as brushing your teeth!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Frederic from Daytona Beach, FL
- Parts Used:
- 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Refrigerator quit running
I located the part that was the culprit as it had buzzed very much before quitting. This is an easy removal as the part is in a two prong jack and just needs to be carefully removed with the new part inserted back in the jack provided. The refrigerator works fine now, but the run capacitor will still buzz on start up of the compressor. I do hope this is normal in this model? anyway it runs fine mow. Thank you.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jennifer from Jonestown, TX
- Parts Used:
- 216008900
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Stopped working, cooling.
I used a small screwdriver to disconnect wires from old starter. I connected the overload and starter, two wires. I put the unit back in the keeper, plugged the unit in, turned up the thermostat and it's working beautifully.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roger from Rochester Hills, MI
- Parts Used:
- 218720500
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Socket set
Ice maker stoped working and the water dispenser also stopped working at different times.
Pulled unit away from the wall. Removed backing from lower controls and compressor. Unhooked water lines and wires to solonoids and removed malfunctioning valve. Hooked new valve to the the plastic water lines, connected wires and mounted new valve to the back support plate.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- paul from traer, IA
- Parts Used:
- 5303918277
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
ice maker would not make ice
un plug fridge. removed ice maker from fridge. loosen 2 mounting screws. lift unit in slots to get over heads of screws. unplug wire harness. remove cover. remove 3 screws from control housing. remove 2 motor mounting screws. unplug motor wires from switches w/needle nose. installation is the reverse. plug in fridge turn on icemaker. takes 10 to 15 min to start to cycle.
easy and cheaper than new fridge or ice maker
easy and cheaper than new fridge or ice maker
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from Springfield,, TN
- Parts Used:
- 5300158289
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Fan Noise
took cover off inside freezer control . removed old fan and unpluged wire harness plugged new one up and fastened back in place and put control cover back on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- debra from new washington, OH
- Parts Used:
- 5303917954
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
freezer kept icing over, refrigerator too hot
First, I unplugged the appliance. Safety, first.
Than I removed the shield which was held in by screws. This covered the fan, thermometer.
The defrost thermostat was taken out, with a little extra force. The wires on the defective part were no longer attached to the part. The instructions were easy to follow in replacing the defrost thermostat. I stripped the coating on the wire, attached it with the enclosed electical bugs. The assy was able to follow, and the part went back on. The refrigerator is working perfectly. I couldn't have done it without the help in diagnosing the problem and with the speedy delivery of the new part. Thanks for all your help and the ease of the installing the new part!
Than I removed the shield which was held in by screws. This covered the fan, thermometer.
The defrost thermostat was taken out, with a little extra force. The wires on the defective part were no longer attached to the part. The instructions were easy to follow in replacing the defrost thermostat. I stripped the coating on the wire, attached it with the enclosed electical bugs. The assy was able to follow, and the part went back on. The refrigerator is working perfectly. I couldn't have done it without the help in diagnosing the problem and with the speedy delivery of the new part. Thanks for all your help and the ease of the installing the new part!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard Allen from PHOENIX, AZ
- Parts Used:
- 241798231
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Replacing Icemaker
Pull refrigerator from wall and disconnect the water line and unplug the power.
On top of the icemaker, two machine screws hold the icemaker to the side of the refrigerator. You will have to feel around to find the machine screws, but once you do, it is simple to slip the appropriate size socket over the hex heads. I found it helpful to have an extension on the socket wrench. Disconnect the power cable inside the refrigerator (there are little pressure clips on the side that help release the cable) and move it out of the way for the time-being.
Back out both machine screws several turns, but do not remove them completely. The icemaker slips over the screws, so leaving them in the side of the refrigerator makes that process a lot easier. Hand tighten the machine screws once you have positioned the new icemaker in place. One thing to be sure and do is make sure the water line hose coming out of the back of the refrigerator inside is on top of the icemaker. It fits into a slot in the top of the icemaker - failing to do this will result in water pouring into the freezer compartment, not into the icemaker..
Reconnect the power cable to the new icemaker and tuck it up behind the icemaker assembly. Tighten the machine screws completely, but do not over-tighten.
Reconnect the water line on the back of the refrigerator at the wall, and plug in the refrigerator. You should hear the unit fill immediately.
In about an hour you should have ice filling the bin. Enjoy!
On top of the icemaker, two machine screws hold the icemaker to the side of the refrigerator. You will have to feel around to find the machine screws, but once you do, it is simple to slip the appropriate size socket over the hex heads. I found it helpful to have an extension on the socket wrench. Disconnect the power cable inside the refrigerator (there are little pressure clips on the side that help release the cable) and move it out of the way for the time-being.
Back out both machine screws several turns, but do not remove them completely. The icemaker slips over the screws, so leaving them in the side of the refrigerator makes that process a lot easier. Hand tighten the machine screws once you have positioned the new icemaker in place. One thing to be sure and do is make sure the water line hose coming out of the back of the refrigerator inside is on top of the icemaker. It fits into a slot in the top of the icemaker - failing to do this will result in water pouring into the freezer compartment, not into the icemaker..
Reconnect the power cable to the new icemaker and tuck it up behind the icemaker assembly. Tighten the machine screws completely, but do not over-tighten.
Reconnect the water line on the back of the refrigerator at the wall, and plug in the refrigerator. You should hear the unit fill immediately.
In about an hour you should have ice filling the bin. Enjoy!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Guy from Califon, NJ
- Parts Used:
- 215501901
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Condensor fan motor failed
Removed the old fan--three small nuts and snap off connection. Ordered part and received the next day. Your company is great!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- alonso from Compton, CA
- Parts Used:
- 5300158289
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Wrench (Adjustable)
Freezer starter acumulating lots of ice and the lower part of fridge was not cooling at all.
just took the back cover of the freezer of and then the fan. To do this, I just removed like four bolts at the corners and then four bolts that attached the fan to the cover. At the end, I just unplugged the cables. I got my new fan the very next day, which was like extremly fast, plug in the cables and attached the fan to the cover and then attached the cover to the original place. It's a pretty simple repair. My fridge is now working like it should be.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffrey from Indianapolis, IN
- Parts Used:
- 5303918277
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice maker was not making ice
I replaced the solenoid first because the ice maker was not getting water. After replacing the solenoid valve, I waited about 1/2 an hour, still no water. So, I ordered a replacement ice maker. I then installed the replacement ice maker, waited a 1/2 an hour, still no water. Then, I waited overnight. Yeah, ice! WORD OF ADVICE. WAIT OVERNIGHT TO SEE IF THE ICE MAKER CREATES ICE. Not sure how long a cycle takes, but it's longer than you would think. Hope your installation is a success!
Was this instruction helpful to you?