ANGELA from MEBANE, NC
Parts Used:
316538904
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Refrigerator Light bulb went out
I replaced the bulb using my hands to twist the bulb in the socket located at the top of the refrigerator.
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Arthur from Lithonia, GA
Parts Used:
5303917954
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Freezer was getting a build up of frost on the condenser and wasn't cooling.
First I remove the back panel which had 4 screws. Then I removed the ice maker. The icemaker is held in place by the 2 screws that requires backing the screws out just a litter, than lift up and remove the electrical connector. Used a volt ohm meter to check the resisitant in the heater element and the defrost timing switch. Both tested good and that left only the thermostat. Removed and replaced the thermastat swich. I cut the ends of the old switch and crimp the ends of wire with the crimps that came with the swict i purchased from parts select. My refrigerator is working properly and making ice like normal.
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fernando from La Grange, AL
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Wrench set
freezer would not defrost
tested defrost timer and heater. And then tested defrost timer with ohm test($6 at hard ware store) Closed and would not open replace and tested freezer take 30mins to get switch cold and retest.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from LECANTO, FL
Parts Used:
5303288973
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Broken crisper holder (bracket)
Removed broke bracket. Installed new bracket (part #100). Now, everything is O-TAY!
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from ABINGDON, VA
Parts Used:
5304464438
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Fridge would not cool at all, because the compressor was not running. Fan running, lights working, just no cool.
Remove the cardboard access cover at the bottom back of the fridge. On the left side, locate the run capacitor. Remove it by prying it loose from its socket, after first removing the wire hold down clamp. One wonders why the clamp is there, which makes it difficult to get the run capacitor out. Be careful not to disrupt in any way the copper refrigerant tubes. If you mess them up, you will have wasted your time and effort trying to repair the machine. I was lucky, since a failed run capacitor is the problem only about 12% of the time, based on what I’ve read. Hallelujah! It was the problem with my fridge.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Darrell from Bentley, ND
Parts Used:
5300158289
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
the evaporator fan quit when we had a power surge
A screw driver was used to remove two screws that held the old fan in place the new fan ws installed exactly where the old one came out and presto the job was complete. No major deal.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alan from SAN MATEO, CA
Parts Used:
316538904
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Repaired Oven Range Light Bulb
The bulb has a plastic clear cover. That cover can just be carefully removed using a screwdriver. It's held in by a metal bracket. After you remove the cover. You'll just need to replace the bulb and then re-install the cover and bracket.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rosemarie from BOYNTON BEACH, FL
Parts Used:
218428101
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Door Handle Broke off
Part arrived in tack.
Removed original screws. Place bottom of handle on sideways then horizontal position.
Next slightly raised top of handle over bump protector. Took orginial screw and screwd Top of door handle into place. Really easy!
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Partlow, VA
Parts Used:
5300158289
Difficulty Level:
Very Difficult
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Motor squeal
I didn’t do the repair because the new motor had a female pigtail connector while the original motor has male connection. It came with wire clamps but didn’t want to cut wires to make repair. The pictures online show a male connection. Put the old motor back in and now it works fine.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kyle from Porter, OK
Parts Used:
5303917954
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Freezer coils kept freezing over.
1. Turned off the cooling cycle and unplugged the refrigerator.
2. Removed all of the shelving and bottom basket.
3. Removed rear covering in the freezer section.
4. If frosted over, manually defrost coils with hairdryer.
5. Located original thermostat and after marking the wire locations cut the wires and removed the Thermostat.
6. Connected matching wires using a lighter to melt the wires together. Wrapped repaired wires with electricians tape.
7. Unable to install the thermostat in the recommended location (freezer is a tight fit) the new part was installed at the original location.
8. Replaced the rear cover and shelves.
9. Plugged in the refrigerator and set the cycle back to cooling.
10. Monitored freezer coils couple of days/weeks depending on how fast they freeze over (slots at bottom of cover) to validate if problem solved.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Don from MELBOURNE BCH, FL
Parts Used:
218428101
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Handle broke off of door
New handle was easy to obtain from you and had the new one on in ten minutes. Thank you Very easy repaired.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marilyn from LOS ANGELES, CA
Parts Used:
218428101
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Someone broke ref. Door handle in garage, with car door!!!!
Just screw new one on again. All done, like new
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
chester from Oak Lawn, IL
Parts Used:
215501901
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Fan not running.
removed old fan and replaced it.3 screws and plug.Always unplug appliance when working on it.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerry from PHOENIX, AZ
Parts Used:
5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Freezer was freezing but refridgerator was warm. Checked fan and it was not turning.
Unplug fridge. Removed 2 nuts to get the vent plate off and two more nuts to get the motor mount off. Removed fan blade and then the fan motor. I put the new motor in and put everything back as it was. It was very easy. I had items in the freezer, so I didn't turn the fridge off other than to replace the part. It took about 6 hours for the fridge to reach optional temps because I didn't get to defrost and the fridge had to work it out on it's own. If you don't need the freezer then you should turn the refridgerator off for at least an hour and open the doors so the coils can defrost and any ice blockage between the freezer and fridge portion can melt away as well.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Justin from FRANKLIN, TN
Parts Used:
5300158289
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
The original fan motor began masking a noise and finally stoped working.
Followed video instruction and completed the replacement. I had to join the wires since the connector was a male plug to a make plug.
2 of 2 people found this instruction helpful.