PLRU1778ES0 Frigidaire Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Raymond from Houston, TX
- Parts Used:
- 240524102
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
I broke the fan while cleaning the coil
The broken fan made my refrigerator sound like a lawn mower I pulled the refrigerator out of it's nook and disconnected the power, removed the back panel with my battery powered drill motor, slid the old fan off of motor shaft, slid the new fan back on ran it to make sure the problem was corrected. The entire repair took less than fifteen minutes and was as simple as it could be. Please be careful when cleaning your coil, as the fan is easily damaged if you should contact it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jim from Carlsbad, CA
- Parts Used:
- 240338001
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Plastic Shelf Broke
Snapped in place in less than 30 seconds
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from SEQUIM, WA
- Parts Used:
- 5304518034
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Freezer would not run; no electrical power to the compressor
Looking on-line at your diagnostic for this problem, I saw the most common part to cause this problem was the start capacitor, so I purchased one & installed it with no positive outcome. I then purchased the next recommended part which was a defrost timer & installed it with no run again. Frustrated, I looked at another diagnostic web site that claimed 90% of the time the problem is caused by the cold control thermostat. I tested mine and it tested bad, so I bought a control elsewhere, since your site did not list a PN for that device. I installed the new control and the freezer started up correctly. Looking at the wiring diagram for these parts, I see the start capacitor and defrost control are downstream of the cold control thermostat, and to my mind should have been the first part recommended for testing versus the parts I bought, so I am somewhat disappointed in the diagnostics on your site, where I spent about $80 for parts that were functional.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mike from Los Banos, CA
- Parts Used:
- 297309000
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Evap fan motor intermitant
Removed evap cover from Commercial Refrigerator. Removed mounting screws from Evap motor mount. Replaced evap fan motor. Repositioned. Reinstalled evap cover. Tested . This motor was hard to find locally. Glad I called.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- TIM from Lockport, IL
- Parts Used:
- 240524102
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
broken fan with vacumme cleaner
I remembered to unplug first. took the little cover off on the bottom, unscrewed the 3 screws. then just held the base that the fan is on and pulled rite off, pushed the other one rite on. it took me five min, i want to say thanks to parts select, had the part, fast shipping, great job, thank you.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tom from Argyle, WI
- Parts Used:
- 5304518034
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Freezer not defrosting
Replaced defrost thermostat and defrost timer on my commercial Kelvinator freezer. Took out screws inside freezer compartment that hold panel at top inside freezer.Once the screws were removed I pulled out the thermostat dial so the panel was free to drop down and expose coils to the freezer that were located in the top rear of the inside freezer compartment.The defrost thermostat was located on the top of the coil to the top left as you face the inside of the Kelvinator KFS220RHY1 freezer. Very easy unplug old and plug in new defrost thermostat. Also replaced timer located in the back side of the freezer down near the middle of the bottom of the freezer near the compressor. There were two nuts holding the timer in the back of the freezer once I took those out I just unplugged the old timer and plugged the new timer in ....very simple fix. I have only run my freezer for a week since I replaced both parts but so far all is working well.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Letitia from OFallon, IL
- Parts Used:
- 240338001
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Door Shelf Was borken held together by duck tape
I receive the part the next day eventhough I paid for 3-5 day delivery. It took lest than 10 seconds to snap into place and now it looks like new.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jaime from Harrisburg, PA
- Parts Used:
- 240530811
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Cracked drawer
I slid out the old drawer and slid in the new drawer. Easy as that! I would recommend this website to anyone.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Venita from MENA, AR
- Parts Used:
- 240524102
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Broken fan blade
Followed video instructions which were to unplug refrigerator, on lower back use screwdriver, loosen 4 screws, take off plastic cover, pull out fan, replace with new fan, replace cover and 4 holding screws, plug in refrigerator. I am female, 77 years old and if I can do it, anyone can.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Walter from SALT LAKE CTY, UT
- Parts Used:
- 297309000
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Squealing noise and bottom half of freezer only froze
I removed the shelves, unscrewed the cover panel of the fan motor and regulator dial, disconnected the fan motor from power, unscrewed 2 screws holding the motor to the mounting bracket and put the new motor in it's place. New motor had no thread in the mounting holes, so I put new tread in so I could use the 2 screws. Another option would have been to drill all the way through the mounting holes and use longer screws or bolts. Of course I turned the power off before I started repairs. Freezer runs like new now. Technicians wanted $400 for the job, while it cost me a mere $55 for the Motor.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from McBee, SC
- Parts Used:
- 5303918774
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Socket set
Freezer compartment warm / Ice cream soft
I worked for GM as a Frigidaire Tech, before starting my own business. I have retired now.
I took the three screws off the back of the bracket holding the motor. Disconected wire harness and pulled out the motor. Reverse to install. servantoftheking@hughes.net
I took the three screws off the back of the bracket holding the motor. Disconected wire harness and pulled out the motor. Reverse to install. servantoftheking@hughes.net
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marsha from BEVERLY, MA
- Parts Used:
- 5304518034
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Wrench set
Refigerator Not Staying Cold
Bought the defrost timer based on PartSelect recommendations, installed it and no change. Apparently the old one was fine but since the refrigerator was in a flood and this part got submerged in water I kept it rather than returning it. I looked at everything closely and realized all the mechanical functions were working properly. Rarely does a condenser coil fail so I decided to look into recharging the coolant. Bought a 1/4 inch bullet valve, a 12oz. can of R-134a and a cheap resealable can adapter with hose, gauge and R22 to R-134a adapters. After a $30. investment Bingo, after one squirt the refrigerator began to cool and after 4oz. it now works better than new. I understand that PartSelect is in the business of selling only their parts but please consider that there can be other simple problems.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ivette from Grand Island, NY
- Parts Used:
- 218909912
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Freezer wouln't start
First I removed the clamp, pulled out the part, and diconnected the two wires on the side and a small screw. Reconnected the new part with the small screw, connected the wires and plugged the part back to the side of the motor. Whaa La, Done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeanne from SAN ANTONIO, TX
- Parts Used:
- 5304518034
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Freezer was running too warm
Removed the old defrost timer by removing 4 screws on the holding bracket. Disconnected the wire harness. Reconnected the wire harness to the new part. Installed the new part with 2 screws on the top of the molded bracket. I am a 67 year old woman... easy-peasy. (the defost timer is located in the bottom left rear of the freezer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bruce from MARTINEZ, CA
- Parts Used:
- 5308000010
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Fridge made a hellacious noise and wasn't cooling well
From discussions with friends, I determined the problem might be easy to fix. The fridge made a lot of noise, but the compressor DID come on, and inside the freezer was cold, but the main fridge was warming.
After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to uncouple.
I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.
I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to uncouple.
I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.
I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
Was this instruction helpful to you?
Thank you for voting!