PAUL from WEIRTON, WV
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
freezer frosted up and air could not circulate to the food section, causing the temperature to get warm, 55 degrees
I followed the procedure online and found the thermostat was ok, it had continuity when cold, and the heater coil was also ok, it too had continuity, therefore the problem was a bad defrost timer. the refrigerator works great, thanks parts select!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Diane from San Antonio, TX
Parts Used:
5303325991, 5303325990
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
The small tabs broke off in one of our many Miltary moves. For ten plus years I have not had the use of the door shelves.
This poor frig.(purchased in 1984) has gone thru five military moves. Somewhere along the line the plastic tabs to the door shelves broke, but I retained the metal bars. I hoped to find the required plastic ends to fix them and you had exactly what I needed. The repair was so fast and easy. The amount of pressure was a bit more than I originally thought was needed but they all went in perfectly.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dean from Sunset, SC
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Freezer worked, Frig would not cool.
Unplugged the frig. Removed temp control module from frig, 1 screw with nut driver. Activated defrost timer by rotating adjustment until 2 clicks are heard. Removed two timer mounting screws, unpluged timer, plugged in the new timer, mounted it to the control module with 2 mounting screws. Replaced control module with the 1 mounting screw. Closed door and plugged it up.
Was this instruction helpful to you?
Thank you for voting!
Customer:
BILL from GENOA, WV
Parts Used:
5303917954
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Refrig unit was frosting up top and bottom, did not properly defrost and stop cooling especially in lower compartment.
Unplug the refrigerator unit from wall. I removed freezer rack, plastic light cover, the ice rack shelf on the right side, then removed the plastic back cover panel, (4) retaining screws, gently tilting the panel toward me, unplug the wiring harness by depressing the clips on the side of the plug, removed panel from unit, set aside. If the unit was froze up, so I defrosted the cooling coils carefully with a common hair dryer until it was thawed. Be careful not to touch or bend the coils , since they are very fragile and SHARP! I located the old thermostat unit attached to a straight length of coolant line. The new unit looked like the old one, so it was easy to locate. I cut the two wires of the old unit close to the round base to make sure I would have enough wire to reconnect. Since my new unit did not indicate a polarity(Neg or Pos), I just wired each wire I cut to one of the new unit. I used the shrink tubing provided and heated the shrink till it was fully melted. I double ck'd to see if the wires were basically waterproof and a good connect. Also, before I replaced the rear panel, I made sure that both wires I had spliced had a drip loop to it so water would not drip down into the newly spliced union. Also made sure the wires will not interfere with the colling fan on the back of the rear panel. Reverse the procedure in reassembling. Plug in unit, and wait and listen for the unit coming back on..I kept a regular thermometer in the upper and lower compartments. Allow 24 hrs. for the unit to return to normal operation. It may defrost several times till the whole operation is back in sync.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barbara from Marcellus, NY
Parts Used:
5303200810
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Failure of temperature control
Unplugged refrigerator. Removed control knob and cover. Unwired control and removed same. Removed plastic tube from old capillary tube and placed on new unit. Installed and wired in new unit, making sure new unit was in the "off" position. Plugged in refrigerator, turned control knob to the first numerical setting, and was rewarded with the startup of the refrigerator compressor. Voila!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jim from Coulee City, WA
Parts Used:
215846602
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
the fridge was freezing all the food.
I watched the video you had on-line and it was simple. Thank you so much
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dana from Bloomington, IN
Parts Used:
5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Fan Motor Noisy
Emptied freezer, removed fan motor cover (2 screws), removed fan and motor (2 screws), removed old motor from bracket and reassembled with new motor, transferred fan blade from old motor to new), re-installed new fan/motor (2 screws) and reinstalled cover...
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bonnie from Plain City, OH
Parts Used:
5300158289, 215846602
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers
Freezer Was Cold, Refrigerator Was Warm
I found this website via a google search and clicked on the link suggesting solutions for the symptoms I had. I decided to order the part (defrost timer) that was proven the larger percentage of time to fix my issue (warm refrigerator) but decided to also purchase the evaporator fan motor as it was suggested by my brother to replace it as well. We powered off the refrigerator and removed the back wall of the freezer and completely defrosted the unit. This seemed to be the most work and longest time to complete. We used a hair dryer to do this. Once the ice was gone, we replaced the defrost timer, which seemed to fix the warm refrigerator part. We didn't immediately swap out the evaporator fan as the power plugs did not connect properly and it was a little confusing on how to accomplish this. I called partselect back and they didn't have anyone that could talk to me throught the replacement process but recommended we call frigidaire. Meanwhile, we found out that the defrost timer corrected the warm refrigerator and now that the evaporator fan could move (no longer frozen in ice) it was making a lot of noise. So we contacted fridgidaire, and they were able to provide me with a similar video on connecting the power between the new evaporator fan motor and the refrigerator. . We ended up snipping both power connectors (from fridge and new part) and twisted the wires togehter and now the fan is moving without noise, the freezeer and refrigerator is working like a champ! Very happy outcome!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Memphis, TN
Parts Used:
5303917954, 215846602
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
refrigerator was not cooling
Ordered new parts, removed old parts, put in new parts. Done.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Exton, PA
Parts Used:
5303917954, 215846602
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
Freezer icing up
Part Select suggested probable causes and supplied videos of how to make the repair of a 25 yr.old refrigerator along with the specific parts to order. I was about to trash the old refrigerator but after replacing the parts for a total of about $40 and 1 hour of time it works fine now.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerald from Goldsboro, NC
Parts Used:
5303917590
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Wrench set
Deforst Drain Pan rusted out
The old drain pan had a 1 ½” tall bushing attached to the center of the pan. The new pan did not have this bushing which was great. I had to cut about 1 inch off the bushing to remove the old pan. Also after cutting the bushing I had to screw the bushing off after cutting the old pan from the bushing. I installed new pan onto the ½” of threads that was left on the top of the compressor. Checked repair two days later all was great.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Wayne T from Galway, NY
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Freezer was not defrosting thus refrigerator was not cooling
1. Unplug the refrigerator.2. Remove the storage rack and back panel in the freezer. 3. Locate the thermostat. 4. Defrost the freezer coils , i used a hair dryer. 5. Remove the thermostat from the cooling coil and then clip the connecting wires close to the unit. 6. Strip the ends of these wires and connect these wires to the wires of the replacement unit using the supplied wire connectors. 6. Heat seal with a lighter the connections using the water shield sleeves provided and further wrap connections with electrical tape. 7. Reconnect the thermostat to the cooling coil at the location it was removed from. 8. Replace the freezer back panel removed earlierand the storage rack if you have one. 9. Plug the freezer back in. My refrigerator has been working ever since the repair. There are several YouTube videos available that walk you through the diagnoses and repair process. They are very good.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ronnie from Abbott, TX
Parts Used:
5317842502
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Freezer was freezing up and would run all the time and not cycle off.
Unplug the refrigerator. You will ultimately need to remove the back panel of the freezer. But first, you will need to unscrew 2 screws on a small vertical fan vent and unscrew two screws on the fan. Maneuver the fan out of the round hole in the back panel and unplug the 3 prong wire connection. Then remove the fan. Unscrew the 4 remaining visible screwson the back pannel and remove the panel. This will expose the freon coils. On this model, the heater has two connections at the top of the coils. Unplug those wire connections. The heater extends down each side of the coils and along the bottom of the coils. Unhook two aluminum ties that connect the heater element to the coils. These ties stabilize the heater element and also prevents any current from flowing along the element because of the touching of two different metalic parts. Maneuver the heater element out of the coils. To install the new heater, reverse the above process beginning with installing the new heater element. If it hasn't already been done, it is good idea to test the old heater element with an ohm meter to make sure that the element is actually bad. The circuit should be open. This is the second heater element that I had to replace on this refrigerator, and it was actually burned in half both times, so I knew for sure the element was bad. Then test the new element to make sure it is good, and start the installation..
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from merrillville, IN
Parts Used:
215846602
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Heater not coming on - coil frosting up- freezer and Refrig. warm
The instructions given to me by part Select were very good.I replaced the Timer- checked the heater with oham meter it was good- checked the door weather striping it was good and replaced the thermostat with new .So at this point I may need to call a professional unless some one has another solution.
Was this instruction helpful to you?
Thank you for voting!
Customer:
K from Lakeview, MI
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
Refrigerator side not cooling (of Side by Side)
Turned off Refrigerator by thermostat switch in Freezer Compartment,(allowing for light to work in freezer). Then removed all food from freezer side,then all shelves & basket drawer. Next, unplugged refrigerator from electrical source. Removed back of inside of the freezer. Located the Thermostat for defrosting cooling coil. Removed and replaced with new part.(Tip-unplugged the wires for the original thermostat, remove from freezer and cut off and splice with connectors provided with new part, it's easier because you're not trying to do this in the narrow space of the freezer). Then attach the thermostat with new bracket and plug thermostat wires back in, replace back panel, shelves, plug in power supply, turn thermostat switch in Freezer to normal setting. Wait for Freezer to cool and replace food. It's currently working like new. BTW I thought I need a defrost time as well...however after I ordered that part and received it, I turned the existing defroster timer manually with a straight ended screwdriver very slowly and it cycled and the defrost rods glowed/functioned just fine. Therefore I didn't replace defrost timer. I'll save the new timer for future repair if needed. All in all it was fairly easy, and I didn't have to buy another fridge. I was really pleased with the service of this website...and the parts arrived very quickly via Fedex. Thanks www.partselect.com ! KJ
Was this instruction helpful to you?
Thank you for voting!