- Customer:
- Jack from WALLING, TN
- Parts Used:
- 241639502
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Socket set
Fridge started making a loud racket. Condenser Fan Blade then disintegrated to dust and pieces. The plastic had degraded significantly.
The repair itself total time was quick and easy. Since the original fan blade blew apart, it was only a matter of putting the new one on in it's place. This can be done by feeding the blade between the cowling and Condenser coil and applying pressure to get it on the shaft.
If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.
In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.
Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.
Hope this helps someone. :)
If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.
In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.
Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.
Hope this helps someone. :)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- DAVE from CRESTON, IA
- Parts Used:
- 241684503
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers
Ice maker would not dischare ice
Followed the online video from this site
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joel from SODUS POINT, NY
- Parts Used:
- 242252702
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
No water to ice maker
Repair was easy. Unplug refrigerator, turn off water to ice maker, remove back panel, disconnect water inlet valve, disconnect water supplies and electrical connections. Cut ends off tubing to modify to new part connections, connect tubing, connect electrical supplies, reinstall back panel, plug refrigerator in, turn water supply back on. We made sure that there was no ice build up in the supply tube into the ice maker and made sure that everything worked correctly before putting it all back together. It was an easy repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from SEATTLE, WA
- Parts Used:
- 242009604
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Water filter would not disconnect from OEM Water Filter Base
Disconnect the two water supply tubes at the base of the Water Filter Base. Using a 7/16" open end wrench, press up on the blue "O" rings to disconnect the tubes. Use a Using an 8" long magnetic phillips head screw driver I was able to unscrew the 4 short screws holding the original water filter base and the immovable attached water filter. Replacement was easy. Simply slide the new base into the fixed slot on the refrigerator and reinstall the 4 holding screws. Reconnect the water supply tubes to the Water Filter Base. Install a new water filter.
Was this instruction helpful to you?
Thank you for voting!
I HAD 2 BROKEN BINS, THIS COMPANY HELP ME TO FIND MY NUMBER. OF PARTS
WAS SO EASY, THE PART WAS PERFECT IN SIZE AND EVERYTHING.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ville from SAN JOSE, CA
- Parts Used:
- 241547902
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Ice maker doesn’t work
Open freezer
Pry the switch out (bottom first, then push the tab on top while prying out)
Move wires to
New switch
Push switch in
Test
Pry the switch out (bottom first, then push the tab on top while prying out)
Move wires to
New switch
Push switch in
Test
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bill from FORT MYERS, FL
- Parts Used:
- 241860803
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Icemaker jammed
Installed new Auger drawer assembly
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John A from BRUNSWICK, GA
- Parts Used:
- 242252702
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
No water to ice maker
Original unit had screw on lugs. After removing old unit, I unscrewed the lugs, cut the lines to remove the nuts and inserted them into the new unit. Everything was color coded so connection was simple. Reinstalled unit, cycled the ice maker several times only to discover the fill tube at in the freezer had frozen ice blocking the tray from getting water. Used a hair dryer to thaw out the tube, water flowed instantly. Very easy repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- GEORGE C from Sweet Water, AL
- Parts Used:
- 241860803
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Would not dispense ice.
Very simple installation.Gentle pull out on the old Ice Container and Auger Assembly.Take the new Ice Container and Auger Assembly and slide in place.Make sure everything is lined up.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Billie from ROGERSVILLE, MO
- Parts Used:
- A01078804
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Double door. Refrigerator control panel displayed HI [temp 55*f or higher]
I bought and replaced the control board as suggested. It didn't help. It was suggested that it was the Damper [lets cold air from the freezer into the refrigerator side]. I bought a new Damper unit. It didn't help. It was suggested that I replace the temp sensor[s]. I replaced them both, and the HI alert disappeared, but it did not help with cooling the refrigerator. I gave up after spending $400 on parts with no solution; I bought a new double-door refrigerator.
Note .... None of these parts come with any instructions. You have to watch youtube.
Note .... None of these parts come with any instructions. You have to watch youtube.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sam from Ravenswood, WV
- Parts Used:
- 241850615
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Wrench set
Not making ice
Took out old replaced with new. Now it makes ice
Was this instruction helpful to you?
Thank you for voting!
Ice Crusher Houseing cracked broke into pieces
Remove ice drawer ,Removed front of drawer 4 screws ,Removed broken crusher 3 screws Ordered new parts reassembled replaced fix blade spacer that was broken and blade cover housing reattached front of drawer !
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Les from LIVERMORE, CA
- Parts Used:
- 241885001
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
The ice crushing housing was broken.
The repair went easily after watching the video, took me less than an hour to complete the repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- shawn from CORTEZ, CO
- Parts Used:
- 241885001
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Ice crusher selection door broken
Removed ice bucket from freezer. Remove ice. Remove 2 phillips head screws from the inside front of ice bucket, and 2 fromt the bottom front to remove the front cover. Remove the E clip and washer from ice crusher shaft. Remove 4, 1/4” head screws from ice crusher housing. Unclip the selector shaft from crusher door paying attention to position.Slide housing off of shaft and discard. Install new housing over shaft and install the 4 screws. Install selector shaft into door. Install the E clip and washer onto shaft. Install front housing with the 4 screws previously removed. Refill bucket with ice and install bucket back into freezing taking care to orient the ice screw shaft into the cog in the back of the freezer as well as the door selection shaft. Test operation.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Glen from HENDERSONVLLE, NC
- Parts Used:
- 242077705, 5308000010
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
EVAPORATOR FAN MOTOR & BLADE
The service manual diagram shows the 149 complete fan shroud in a vertical (upright) position. Misleading! Of course.
The actual mounting of the lay in fan shroud fully assembled is in the horizontal position laying in a tray area just above the evaporator coil cage assembly. The entire shroud assembly can be installed incorrectly by the diagram and will still fit. BUT... no cold air will flow or be forced into the ice maker vent nor the refrigerator vent. I found this out the hard way by trial & error.
If the drawing had shown it in the horizontal position for both removal and reinstallation... it would have saved a lot of time and headaches. Also, the diagram does not show the (2) plastic angle supports on the shroud, another scratch your head event. Parts included on drawing... 149, 5, 8, 9, 13, 14 on CTFFHS2611PF4 diagram page of service manual.
ALSO, the (4) lower cabinet plate screws have to be removed, and the first left hand screw counting up to allow the next upper panel to swing out enough to lay the shroud in correctly (horizontal) on top of the evaporator coil cage. BOTTOM LINE... THE AIR FLOW HAS TO BE UP IN ORDER TO WORK PROPERLY.
The actual mounting of the lay in fan shroud fully assembled is in the horizontal position laying in a tray area just above the evaporator coil cage assembly. The entire shroud assembly can be installed incorrectly by the diagram and will still fit. BUT... no cold air will flow or be forced into the ice maker vent nor the refrigerator vent. I found this out the hard way by trial & error.
If the drawing had shown it in the horizontal position for both removal and reinstallation... it would have saved a lot of time and headaches. Also, the diagram does not show the (2) plastic angle supports on the shroud, another scratch your head event. Parts included on drawing... 149, 5, 8, 9, 13, 14 on CTFFHS2611PF4 diagram page of service manual.
ALSO, the (4) lower cabinet plate screws have to be removed, and the first left hand screw counting up to allow the next upper panel to swing out enough to lay the shroud in correctly (horizontal) on top of the evaporator coil cage. BOTTOM LINE... THE AIR FLOW HAS TO BE UP IN ORDER TO WORK PROPERLY.
Was this instruction helpful to you?