Models > FP18TLF1 > Instructions

FP18TLF1 Frigidaire Refrigerator - Instructions

Jump to:

All Instructions for the FP18TLF1
121 - 135 of 190
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Gerry from Apache Jct, AZ
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
changed defrost timer
followed the video very esay
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Long Beach, CA
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers, Socket set
Freezer wouldn't go in to defrost cycle
After some troubleshooting to ensure the thermostat and heating element were working, determined that the defrost timer was the problem. With the defective part, I was able to manually advance the timer to activate the defrost cycle, but it wouldn't do so on its own. Unplugged the refrigerator from the wall. Timer is located in the refrigerator compartment at the very top. The compartment houses the cooling thermostat, the light bulb and the defrost timer. Using 1/4" nut driver, remove 4 screws holding compartment cover to top of fridge. Lower a bit to access electrical wiring. Wiring harness can be unplugged to work on the timer away from the fridge which makes it a bit easier. Timer is mounted with 2 phillips head screws. Remove screws and unplug timer from wiring. Install new timer, plug in wiring, secure with the phillips head screws and remount entire compartment.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bertha from Lakewood, CA
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Refrigerator warm and freezer defrosting too quickly.
1. Disconnected electrical. 2. Removed upper console in refrigerator by removing 2 nuts. 3. Disconnected wiring from console. 4. Removed 2 screws from defroster timer part and pulled off from connector. 5. Replaced with new defroster timer and put everything back together. Thank you Steve for the U-Tube step by step video.
Was this instruction helpful to you?
Thank you for voting!
Customer:
hugh from delray beach, FL
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Frig did not run
Simply replaced the defrost timer located inside the frig just behind the temp dial. Very easy job. Removed the 3 screws holding the temp sw and light assembly. Removed the defrost timer w/ 2 screws and put i all back together. 15 mins at most. Suggest you watch the install video for pointers.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mainul from Portland, OR
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The refrigerator part was not cooling enough
I watched the video online where it described the troubleshooting tips for this type of symptom. So I knew exactly what the problem was which is the defrost timer. After the part came in I just unscrewed (4 screws) the box which houses the thermostat and the defrost timer from top ceiling of the refrigerator section. Then I just unscrewed and unhooked the old defrost timer and replaced it with the new one. After finishing the installation I turned the fridge on. At first nothing happened. So I turned the dial on the defrost timer with a flathead screw until it clicked and the fridge came alive. I waited for an hour or so. The cooling cycle completed and the fridge stopped as expected. When I opened the door I noticed the interior is much colder than before and right after closing the door the fridge hummed back into life again. So I know my fridge is working again. Thanks to PartSelect for providing the right part for my refrigerator. I will definitely buy from them again if anything goes wrong.
Was this instruction helpful to you?
Thank you for voting!
Customer:
BILL from GENOA, WV
Parts Used:
5303917954
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Refrig unit was frosting up top and bottom, did not properly defrost and stop cooling especially in lower compartment.
Unplug the refrigerator unit from wall. I removed freezer rack, plastic light cover, the ice rack shelf on the right side, then removed the plastic back cover panel, (4) retaining screws, gently tilting the panel toward me, unplug the wiring harness by depressing the clips on the side of the plug, removed panel from unit, set aside. If the unit was froze up, so I defrosted the cooling coils carefully with a common hair dryer until it was thawed. Be careful not to touch or bend the coils , since they are very fragile and SHARP! I located the old thermostat unit attached to a straight length of coolant line. The new unit looked like the old one, so it was easy to locate. I cut the two wires of the old unit close to the round base to make sure I would have enough wire to reconnect. Since my new unit did not indicate a polarity(Neg or Pos), I just wired each wire I cut to one of the new unit. I used the shrink tubing provided and heated the shrink till it was fully melted. I double ck'd to see if the wires were basically waterproof and a good connect. Also, before I replaced the rear panel, I made sure that both wires I had spliced had a drip loop to it so water would not drip down into the newly spliced union. Also made sure the wires will not interfere with the colling fan on the back of the rear panel. Reverse the procedure in reassembling. Plug in unit, and wait and listen for the unit coming back on..I kept a regular thermometer in the upper and lower compartments. Allow 24 hrs. for the unit to return to normal operation. It may defrost several times till the whole operation is back in sync.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donald from Waynesburg, PA
Parts Used:
5300158289
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Fan Motor Malfunction
Followed the instruction video. Removed the old one. Attached the fan blade, ground wire and connected power plug. Reinstalled with 2 screws. Works great.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Guillermo from Miami, FL
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Freezer iced up, fridge section warm
After reading other posts, I decided to change the defrost thermostat, so I watched the videos, and did that. It got better, but the problem persisted, and the ice was still building up in the freezer section. So I decided that the problem was with the defrost heater. I ordered a new one, that was here under 24hs (using the Fedex ground). I replaced it, measured the old one and saw that it was not passing any current at all (so it was really burnt). Now the fridge is good as new, maintaining the proper temperatures both at Freezer and Fridge sections. Thank you Parts Select ! With $ 70 in parts I was able to get back my appliance working !!!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Glenmoore, PA
Parts Used:
5300158289
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Refridgerator compartment warm but freezer frosty
First I replaced the defrost thermostat, then I realized that the evaporator fan would stop turning periodically. I could restart it by spinning the fan with my finger. The fan is behind a cover in the back of the freezer. If you remove the cover and check on the fan when you hear the condenser fan in the back running. (They seem to run at the same time.) It was easy to replace the fan and the new one is more powerful than the original. The refrigerator runs fine now. Thank you for this great site. Saved me a lot of $$.
Was this instruction helpful to you?
Thank you for voting!
Customer:
jose from brownsville, TX
Parts Used:
5303917954, 215846602
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
The bottom part of the Refrigarater was warm
we removed the food from the freezer, disconnected the fridge , removed the cover, the evaporater fan was running, condeser fan was running, then we checked heater with multimeter and it was ok. next step we replaced the frostimer, and defrost thermostat . and then the refrigarater was working ok, problm was the frost thermastat damaged.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ed from Glendale, CA
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
ice buil up on freezer,not defrosting
first I replaced the timer control hoping thats the problem,unfortunately situation the same ice build up on the freezer.so I replaced the defrost thermostat.right now I'll still observing the condition if still the same.may be in couple days.so far its good.and to replace the parts is not difficult and easy.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eric from San Angelo, TX
Parts Used:
5308000010, 5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Fan Motor was making noise and freezing up.Fan was missing one blade.
Removed screws that fastened bracket to fridge. Next, I replaced the motor and carefully lined the brackets up so the motor would rotate smoothly. Put the fan blade on the motor and screwed the brackets back on the fridge. Motor kept popping out of alignment while I was screwing the brackets back in but I kept snapping it back in till it stayed.
Was this instruction helpful to you?
Thank you for voting!
Customer:
wayne from marietta, GA
Parts Used:
215846602
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
fridge not blowing cold
bottom left cornerof fridge defrost timer replaced two bolts and a wire
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jim from Coulee City, WA
Parts Used:
215846602
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
the fridge was freezing all the food.
I watched the video you had on-line and it was simple. Thank you so much
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barbara from Marcellus, NY
Parts Used:
5303200810
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Failure of temperature control
Unplugged refrigerator. Removed control knob and cover. Unwired control and removed same. Removed plastic tube from old capillary tube and placed on new unit. Installed and wired in new unit, making sure new unit was in the "off" position. Plugged in refrigerator, turned control knob to the first numerical setting, and was rewarded with the startup of the refrigerator compressor. Voila!
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the FP18TLF1