Customer:
CRAIG from PRESCOTT VALLEY, AZ
Parts Used:
297309000
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Noisy fan
Remove the cover panel inside the freezer, remove and replace the fan motor (pull fan blades off old motor and push on the new one) and replace the cover.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Warren, TX
Parts Used:
297309000, 216514000, 216513900
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer only cold on bottom
Pulled freezer out from where located to allow shelves to be removed.Unplugged unit, removed shelves and evaporator cover, installed new fan motor. Plugged unit up to check fan motor operation. Reassembled unit, installed shelves and moved freezer back into original location.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Clovis, NM
Parts Used:
297309000, 5308000010
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Evaporator Fan Motor was making loud rattling sound.
Unplugged freezer from electrical socket. Removed lower trays from freezer. Removed sound proof stripping from sides of back panel. Removed upper, lower and side screws from back, lower panel using No. 2 phillips screwdriver. Disconnected motor wires from quick disconnect power supply. Removed motor bracket from freezer back using nut driver. Removed motor from bracket using same nut driver. Replaced motor and screws in bracket. reattached quick disconnect. Attached fan blade to motor making certain to push blade on shaft securely. Replaced bracket to freezer back. Replaced back cover. Replaced stripping. Plugged into power supply. Total time 15-20 minutes.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from Yulee, FL
Parts Used:
5304518034
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Coils not Defrosting and stopped freezing
Upluged power pulled freezer out from wall removed the two screws that holds the defrost timer unpluged defrost timer pluged new timer in mounted new timer back with the two screws pluged freezer back in and job was complete. Freezer working fine.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from GAINESVILLE, GA
Parts Used:
297013500
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Replaced drawer slides L & R
Removed three screws each side to remove old slides. Needed spacers under new slide so that drawer would stay on track. Cut old slide to make spacers and installed both slides in 15 mins.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scott J from Westminster, CO
Parts Used:
301036
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Side rail for sliding shelf would not stay tight
The sliding shelf side rail is held by three philips head screws that tighten into nut inserts. No amount of tightening would keep two of the three screws tight. I found that the nut inserts which are plastic and insert into the side of the freezer would pull loose, probably from years of overloading the sliding shelf basket. Ordered two nut inserts from PartSelect. 1. Remove three screws to remove shelf slide side rail. 2. Remove nut inserts to be replaced with needle nose pliers or reinsert screw a couple of turns and pull nut insert out with pliers. 3. Insert new nut inserts, position side rail, and tighten screws. Replace sliding shelf/basket.
Was this instruction helpful to you?
Thank you for voting!