Models > FPE17TJW2 > Instructions

FPE17TJW2 Frigidaire Refrigerator - Instructions

Jump to:

All Instructions for the FPE17TJW2
16 - 30 of 55
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
randy from brown deer, WI
Parts Used:
5303917098
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
water was not pumping up to the ice maker
It was very easy. Took off water line and two screws. Put new valve back on and presto life (ice) is good again.
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Partlow, VA
Parts Used:
5300158289
Difficulty Level:
Very Difficult
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Motor squeal
I didn’t do the repair because the new motor had a female pigtail connector while the original motor has male connection. It came with wire clamps but didn’t want to cut wires to make repair. The pictures online show a male connection. Put the old motor back in and now it works fine.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeff from GLENDORA, CA
Parts Used:
5303917954
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
freezer colk, refrig warm
Followed the instructions provided in your video, took less than 15 minutes and works like new. Thank you for the parts and the advice.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carol from OSHKOSH, WI
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
freezer was warm
Top freezer took off the panel in freezer and melted the ice around coils and found the defrost thermostat and replaced with the new one. Just followed the instructions from your video on line. Freezer works just fine now. Refrigerator is 38 years old.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerry from PHOENIX, AZ
Parts Used:
5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Freezer was freezing but refridgerator was warm. Checked fan and it was not turning.
Unplug fridge. Removed 2 nuts to get the vent plate off and two more nuts to get the motor mount off. Removed fan blade and then the fan motor. I put the new motor in and put everything back as it was. It was very easy. I had items in the freezer, so I didn't turn the fridge off other than to replace the part. It took about 6 hours for the fridge to reach optional temps because I didn't get to defrost and the fridge had to work it out on it's own. If you don't need the freezer then you should turn the refridgerator off for at least an hour and open the doors so the coils can defrost and any ice blockage between the freezer and fridge portion can melt away as well.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Justin from FRANKLIN, TN
Parts Used:
5300158289
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
The original fan motor began masking a noise and finally stoped working.
Followed video instruction and completed the replacement. I had to join the wires since the connector was a male plug to a make plug.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
WESTLEY from HATTIESBURG, MS
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Fridge not cooling
My fridge side had warmed up to 70 degrees but the freezer side was still cold. The coils inside had iced up. After thawing with a hair dryer, it froze back after another week. I removed the old defrost thermostat and wired the heater strip directly and turned on the defrost timer. It began melting the ice so that ruled out the heater strip being bad. I couldn't get a reading with my ohm meter on the defrost thermostat so I took a chance and bought the part. Installation was a breeze and it fixed the problem.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fred from Belton, MO
Parts Used:
5303917098
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Ice maker quit making cubes, instead it made a large block of ice.
Unplugged the fridge. Removed water inlet valve from fridge. Used voltmeter to test for resistance (between 50 and 150 ohms). Didn't pass the test.
My original part was 218720400. I ordered part PS468507 from partselect.com. My original part had a "garden hose" coupling so PS468507 fit the bill.
This part's electrical connection wasn't angled the same way as the original so we had to finagle it.
Hooked the plastic refridgerator supply hose up first.
Then screwed on the copper "garden hose" connection to the valve using channel lock pliers. Was careful not to over tighten.
Then the fun started. The electrical connector wires were a tight fit between the copper tubing and the refridgerator frame. Did I mention that the electrical connetion wasn't angled the same as the original? My daughter got her smaller hands in there and was able to make the connection.
NOTE: Because of the angling issue I was unable to screw the anchor plate to the fridge.
I made sure that the valve did not interfere with the fan.
Turned on the water and checked for leaks.
Plugged the fridge back in and in a couple of hours we had ice cubes. Works like a charm!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Myron from West Palm Beach, FL
Parts Used:
5303917098
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set, Wrench (Adjustable)
No water to Ice Maker
Made sure water was going into valve, shut off water to valve, removed it. removed two connections, replaced with new valve, Walla, off & running. Incidentally, rec'd new valve much quicker than I ever expected.
3 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeff from Sunrise, FL
Parts Used:
5303917098
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Ice Make Stopped Making Ice
It was very easy. Pulled off the old valve and replaced with the new one and it started making ice right away. There are a couple of issues you need to be aware of that I am watching closely now. The old valve was a 15 watt valve. The one they sent me is a 35 watt valve. It really pressures the water into the ice maker. So much so I am getting a little leaking from the overflow. Its working so well and powering the water in so fast it starts to leak a little due to being to full. When I ordered the part, no where did it show the wattage of the valve so be careful. It works great but will have to keep an eye on it so it does not overflow.
3 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from WHITE BEAR LK, MN
Parts Used:
5303917098
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Ice maker quit
Removed dead water valve. Installed new water valve.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marvin from Pima, AZ
Parts Used:
5303917954
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Refrigerator keeps frosting up and not cooling
Refrigerator started frosting up and running all the time.I'd defrost it and it would frost up again in about a week.The timer seems to be work so I just guest it mite be the Defrost Thermostat.I removed the duck in the center and back panel in the freezer compartment defrosted it and switched Thermostats and replaced panel and duck, going to lower compartment of the refrigerator.So far it seems to be working a little more time while tell.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Matthews, NC
Parts Used:
5303917098
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Ice maker wouldn't make ice
Needed to replace the valve in the back. My first attempt at a fridge repair. New valve went on in a flash and the ice maker is working great.
1 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Armando from Eagle pass, TX
Parts Used:
5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
the evaporator fan same time won't stater
change the evaporator fan motor kit working perfect
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barbara from Marcellus, NY
Parts Used:
5303200810
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Failure of temperature control
Unplugged refrigerator. Removed control knob and cover. Unwired control and removed same. Removed plastic tube from old capillary tube and placed on new unit. Installed and wired in new unit, making sure new unit was in the "off" position. Plugged in refrigerator, turned control knob to the first numerical setting, and was rewarded with the startup of the refrigerator compressor. Voila!
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the FPE17TJW2