Models > EI23BC30KS1 > Instructions

EI23BC30KS1 Electrolux Refrigerator - Instructions

Jump to:

All Instructions for the EI23BC30KS1
31 - 45 of 123
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Douglas from Denver, IN
Parts Used:
242252702
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Water dripped from water outlet on door
Replaced the Triple Water Valve
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chris from Lockport, NY
Parts Used:
241639502
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
One blade broke from condenser fan
The part i recieved, from parts select was a larger in circumfrence (<1/4) than the original. However i was not aware of this until after i treid to repair it.

I removed the broken fan from the condenser. This was very sipmle.

When i pluged the refridgerator back in to the outlet the fan tried to start up but soon began to make aloud noise, due to there not being enough clerance.
10 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Liberty Twp, OH
Parts Used:
242252702
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Wrench (Adjustable)
Leaking water valve
I ordered the part from PartSelect using the part number located on the valve itself. The part was delivered in less than 48 hours from the time I entered it. Replacing the valve was easy and went according to the online video instructions provided by PartSelect. The only thing extra was that I had to replace the brass compression fitting on the copper tubing connected to the inlet of the valve. The old one would not seal properly. The compression fitting was about $1.50 at Home Depot. This is my third purchase from PartSelect and I continue to be impressed by them.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Allen from Palmer Lake, CO
Parts Used:
242252702
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers, Wrench (Adjustable)
Icemaker worked sporadically, infrequently, not at all
Not knowing the history of the refrigerator/freezer and observing that the icemaker would cycle (ice ejector fingers would rotate when the off/on arm was toggled), I concluded that the water valve must have some hard water scale in it which was causing it to stick. I replaced the water valve and the exact same behavior continued. By elimination, I concluded that the microswitch in the icemaker must be sticking. I removed the icemaker, used a hair blow-dryer to heat/dry out the microswitches and then a little shot of WD-40 on the mechanical arms, switches, and cams fixed it.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kevin from CHICAGO, IL
Parts Used:
241778307
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Torn gasket
Replace gasket
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tim from SYLVANIA, OH
Parts Used:
240597203
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
2 drawer undercounter beverage ref not getting cold enough. Wont get below 48°
Took drawers out by removing 2 screws on top of rail near front, then popped black plastic cover off in lower right inside cabinet...sensor just un plugged and new one plugged in easily...did not fix problem though...display set at 34 but bottom drawer reads about 40 at best and upper drawer reads around 55...dont think the 3 little fans inside on back wall have been running
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Harry from Orange City, FL
Parts Used:
242252702
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench (Adjustable)
freezer filled up with ice leaking from ice maker shut off valve bad
It was real easy took the lines off one by one put them on the new unit one by one same with the three plugs than tighten new unit back on fridge.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Marco Island, FL
Parts Used:
242252702
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice maker was over filling.
Old valve comes out with 2 screws, water lines removed and reinstalled on new valve just as they came off the old valve. Entire job took less than 10 minutes. Very easy replacement.
5 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Melissa from Olden, TX
Parts Used:
242252702
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Icemaker was producing hollow ice due to water was free flowing out the water dispenser during fill time for icemaker.
Removed old water valve w/ screwdriver, cut threads off old hose (as they just plug straight into new valve) & pushed hoses into new water valve. Solved both problems!!!!
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert E from MILL HALL, PA
Parts Used:
240597203
Difficulty Level:
Very Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver
Warm refrigerator temperature
Did not repair, sensor was not located where you said, wrong sensor was sent to me, can't return oe exchange it COSTERMER SERVICE WILL NOT ANSWER MY EMAILS.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jack from WALLING, TN
Parts Used:
241639502
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
Fridge started making a loud racket. Condenser Fan Blade then disintegrated to dust and pieces. The plastic had degraded significantly.
The repair itself total time was quick and easy. Since the original fan blade blew apart, it was only a matter of putting the new one on in it's place. This can be done by feeding the blade between the cowling and Condenser coil and applying pressure to get it on the shaft.

If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.

In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.

Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.

Hope this helps someone. :)
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
ELIZABETH from HENRICO, VA
Parts Used:
242010901
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Wrong Part sent!!!!!
I did not do a repair. You sent the wrong part & I didn't open the package but I can't get hold of anyone to return the part and get the correct part.

I am very upset that no one will help me. I paid $ 37.28 for the part I ordered and then the wrong part was sent

The sku # on the package is 242010901.This is a roller type part and I ordered a small wheel.
I can't even find a return address to send it to.. Please help me
Elizabeth Romage
libbieinrichmond@comcast.net
8042627963
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rene from DIAMOND BAR, CA
Parts Used:
242252702
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Wrench (Adjustable)
LEAKING WATER valve
very easy, make sure to watch the provided you tube video.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John A from BRUNSWICK, GA
Parts Used:
242252702
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers, Wrench (Adjustable)
No water to ice maker
Original unit had screw on lugs. After removing old unit, I unscrewed the lugs, cut the lines to remove the nuts and inserted them into the new unit. Everything was color coded so connection was simple. Reinstalled unit, cycled the ice maker several times only to discover the fill tube at in the freezer had frozen ice blocking the tray from getting water. Used a hair dryer to thaw out the tube, water flowed instantly. Very easy repair.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
fred from Austin, TX
Parts Used:
EAFCBF
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
routine maintenance
slide old filter out and insert new one
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the EI23BC30KS1