Customer:
George from Gilroy, CA
Parts Used:
297309000
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Socket set
condenser fan stop working
Replaced fan. I ordered the fan and received it the following.(-:
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mike from Satellite Beach, FL
Parts Used:
297309000
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Fan would not start occasionally
I unscrewed the screws that held the old fan on, disconnected the wiring harness and removed the old fan. I pulled the blades off the motor and put it on the new fan. One thing of note, the screw holes on the new fan weren't threaded. I assume this is by design, so I used the screws to thread the holes before installing it in the freezer. Once I did this, the rest of the installation was easy, just screw it back in and connect the wiring harness.