CT19X3A Crosley Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Robert from Yelm, WA
- Parts Used:
- WP68233-3
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Refrigurator warm, would not cool. Freezer working fine.
All you need is a 1/4" nut driver or a 1/4" socket and ratchet. Remove the plastic cover to the freezer fan. remove cover to light fixture, bulb, pop out the light socket and remover 2 wires. Remove Ice maker by removing bottom screw and loosing the top 2 screws then lift up and out the ice maker enough to disconnect wiring harness. Revove 4 screws in back panel and the panel can be moved foward. Remove 2 screws holding the fan to the panel. Lay the fan on top of the cooling coil and remove ice maker electrical plug and the panel can be removed easely. Both the heating coil and thermostate switch are easly excessable.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Arlington, MA
- Parts Used:
- W11384469
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Both light bulbs had been replaced, but lights did not turn on.
I tried to remove the old light switch using a putty knife and a hammer. It was hard to compress the plastic tabs to pull it back through the hole, but all of a sudden, the lights came on. I guess banging on the switch freed-up the contacts. The new switch is now a spare part in case I need it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cliff from Metairie, LA
- Parts Used:
- WP10097202
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
compressor will not start - when you turn it on - it hums for a few seconds and them you hear a click sound (the overload opens) and the hum stops
be sure the power cable is NOT plugged into an electrical outlet - removed the cover on the bottom rear of the refrigerator - using a flat blade screw driver pry the cover off the side of the compressor - remove the old relay - remove the wires from the old relay and install them on the new relay in the same location - install the new relay on the compressor connections - snap the cover back on the compressor - replace the cover - power the refrigerator on - the compressor should start and run normally
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paula from Rush, NY
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
light switch sticking
I watched the video and thought "I can do this". Made some notes and then proceeded to remove the old switch and replace with the new one. Thank you.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Irene from Whitehall, MT
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
No light in frig
We tried repairing with a new switch which was very easy to install but it didn't fix the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dennis from Lawrenceville, GA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Light switch which turns on the lights when the door opens went out
This is an easy fix, simply remove and replace. What I was impressed with is that a how to video was provided along with my part. I wish all manufactures would offer this, the video was easy to understand and you had a good view of the operation. Thanks, a job well done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from St. Pete Beach, FL
- Parts Used:
- W11384469
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Broke the arm off the food compartment rocker switch
After receiving the new part almost immediately,using two screw drivers, removed the broken switch from the plastic frame. Be careful not to scratch or otherwise tear the plastic...very pliable. Since the original switch was factory installed and the wires were packed in fiberglass insulation, the switch came out but the wires and clips were still in place and could not reach the new switch. It was necessary to pull them down with bent long nose pliers...used a lot of "pull" but the wires held up.Connected the switch, turned the power on and there was light! Reports from other users really took the uncertainty out of the task.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Salem, WI
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Freezer was not getting cold enough
Mine was alittle different than the online instructions. 1. I removed the motor. 2. I took the fan off the old motor and cut the wires about 3" back from old motor. 3. Mounted the new fan on bracket and put the fan on the new motor. 4.connected wires that were cut and used wire nuts to connect. 5. Mounted bracket and motor/fan to unit and it works like its brand new. Thank you PartSelect!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Henry from Newland, NC
- Parts Used:
- WP68601-6
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Refrigerator was running very cold
Unscrewed the right control knob. Removed the left temperature control knob (there is no screw holding it), removed one screw to rear of small panel then pried open from the rear of the small panel, there are two plastic tabs in front of the small panel holding it in place. Unscrewed the failed control unit and replaced it with the new one. Replaced the small panel and screw then the left side control knob, making sure of the alignment in the "off" position as the knob has to be pressured into a clamp arrangement on the cold control thermostat. Re-screwed the right knob into place, as well.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from New Albany, IN
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Condensor fan motor quit working
Pulled the fridge out, Took bottom panel off. Removed 3 screws holding motor. Unplugged connector, cut wires, attached old connector on new motor. put blade on new motor.installed in fridge, put cover back on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- michael from woodstock, MD
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
excessive water in condensate pan
just as video instructions said, very easy just following them ,part arrived in very short time and was exact fit completely satisfied, saved repair man service charges and wait time
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Hickory, NC
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Condensor Fan going bad
I knew the repair wasn't difficult. It was a matter of finding the replacement part. Luckily, I found the part via the internet on your site. Lucky for me, there was an installation video!! These videos are worth 1000 bucks!! Never have encountered a site with installation videos before. It gave me complete insight as to how the job was sequenced. I'm a very visual person, so videos are the perfect helper for me. With fewer and fewer affordable local service companies around to fix problems like mine, your site gave me the complete confidence to easily switch out the condensor fan. I completed the repair for about $63.00. Your site ROCKS! Keep up the repair videos because they are awesome and extremely helpful. I felt like your pricing was competitive for this item. Thanks again!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- john from thibodaux, LA
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Condensor motor was frozen
pull unit away from the wall, and unplug it. remove the grill, and cardboard guard on the lower back of the unit. remove Three screws for the motor bracket. Remove the bracket legs from the old motor and assemble them to the new motor. take the fan blade off the old motor, place it on the new. Cut the wires at the old motor, strip the insulation back, use supplied wire nuts to connect the new motor. Reverse order to reassemble. Plug in unit to test function.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Andrew from Pinckney, MI
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Freezer was not Defrosting
I have an Amana freeze and I followed the procedure in the video. Which is very good! However on the Amana Model there two slight differences in the procedure that I felt I needed to do. The first one is, the condenser fan bracket is attached to the Freezer chassis with 4 screws, not three. The removal and installation of the back screw by the fan is a bear. I removed the other three and it allowed me to rotate the fan slightly to get more access to the fourth and did same on installation by just starting the 4th screw and then tightening it later. The second issue was my new fan hit the housing when I spun the fan. When I looked at the old one. It had a phenolic washer, between the fan and motor which spaces the fan out about a washer thickness from the motor. When I tried to remove the old one it broke in four pieces due to age. So, I made my own with a washer that I super glued to the motor housing after carefully centering it on and clearing the motor shaft . Seemed to work with out any more noise or balance issues...Thanks, your delivery was blindly fast and video was great!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Martin, TN
- Parts Used:
- WP68233-3
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator was not staying cold enough. Coils in freezer not defrosting.
Unplugged the unit. Removed items from the freezer. Remove 2 phillip head screws from the cover over the coils. Defrosted the unit with a blow dryer. Upon completion of defrosting, put everything back together. Removed items and top shelf in refrigerator to gain access to the controls. Removed a 1/4 inch nut head screw and loosened 2 each phillip head screws. Unplug the controls from unit and placed on kitchen counter. Removed 3 each phillip head screws holding the timer in place and unplugged the timer. Installed new timer, connected everything back together and placed everything back into the refrigerator. Plugged the unit back up and it is now cooling and defrosting properly. This whole process took approximately 45 minutes.
Was this instruction helpful to you?
Thank you for voting!