Models > CT19X3V > Instructions

CT19X3V Crosley Refrigerator - Instructions

Jump to:

All Instructions for the CT19X3V
91 - 105 of 162
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Thomas from Northfield Center, OH
Parts Used:
WP65889-4, WP10097202, 833697
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Socket set
Unit was running loudly and frequently
Followed the utube video demonstration. There was no instructions for changing the relay and overload and so this part was not used.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edward from Sykesville, MD
Parts Used:
WP60106-35
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Socket set, Wrench set
Freezer and Refrigerator not cooling properly
Researched this problem on the web. Disassembled the main refrigeration unit (slide out freezer floor panel). The cooling coils were completely iced up. Thawed overnight. Tested the coil thermostat with a multimeter and discovered it worked. Note that the activation temp on this thermostat is 15 degrees Fahrenheit so the ice-water bath test on many web videos will NOT work. My test was in another refrigerator freezer compartment (everyone has two, right?). When the temperature went below 15 and stayed there for 15 minutes, the thermostat opened the circuit. Further investigation revealed that the defrost heater was burnt and shorted. Replaced the defrost heater only to discover that the defrost timer was also broken. After replacing the defrost timer and testing each component thoroughly, the refrigerator is back in service. Freezer maintains about 8 F and the main refrigerator stays at about 36. The unit cycles off properly and the defrost timer is correctly initiating a defrost cycle. Further, when the defrost heater is cycled on, the thermostat correctly shuts it off once the coils are defrosted. Watch the youtube videos. Find your parts and note their specifications so you can test them properly. And good luck.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barbara from Apollo, PA
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Refrigerator not shutting off, liquids freezing in fridge
It wasn't quite as easy to get to the bolts as the video showed. The lay out of the part wasn't exactly like the video either. However, I managed to put the new part in. Unfortunately, it didn't solve the problem. At first the fridge cycled on and off but after 12 hrs it started to freeze liquids again. Since the appliance was 17 years old we opted to just get a new one.
Was this instruction helpful to you?
Thank you for voting!
Customer:
PHILLIP from SUN CITY CENTER, FL
Parts Used:
WP65889-4
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Nutdriver
Loud, non-rythmic clicking noise shortly after the compressor comes on, continuing for several seconds.
Replaced the "Run Capacitor. The non-rythmic clicking associated with the compressor coming on continues. The problem was obviously not the Run Capacitor". I don't know what to do next. Any suggestion would be appreciated.

Thanks,

Phillip
Was this instruction helpful to you?
Thank you for voting!
Customer:
john from white pine, TN
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
More than 2 hours
Tools:
Screw drivers, Socket set
Fan motor stopped working
Well I could what laid on the floor and replaced it but I didn't I emptied refrigerator laid it over change the motor then stood it back up actual work about three hours
Was this instruction helpful to you?
Thank you for voting!
Customer:
larry from indianapolis, IN
Parts Used:
833697
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Pliers, Socket set, Wrench set
not cooling
removed condenser fan -located behind refrigerator next to compressor, Not much clearance to work, there are 3 screws to remove from condensing motor,sounds easy but clearance is lacking to remove them ,(takes alot of PATIENCE). Then you have to remove the fan blades to be able to get clearance to remove motor!! I wouldn't reccommend trying this repair unless you are a pro.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from St. Pete Beach, FL
Parts Used:
W11384469
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Broke the arm off the food compartment rocker switch
After receiving the new part almost immediately,using two screw drivers, removed the broken switch from the plastic frame. Be careful not to scratch or otherwise tear the plastic...very pliable. Since the original switch was factory installed and the wires were packed in fiberglass insulation, the switch came out but the wires and clips were still in place and could not reach the new switch. It was necessary to pull them down with bent long nose pliers...used a lot of "pull" but the wires held up.Connected the switch, turned the power on and there was light! Reports from other users really took the uncertainty out of the task.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Salem, WI
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Freezer was not getting cold enough
Mine was alittle different than the online instructions. 1. I removed the motor. 2. I took the fan off the old motor and cut the wires about 3" back from old motor. 3. Mounted the new fan on bracket and put the fan on the new motor. 4.connected wires that were cut and used wire nuts to connect. 5. Mounted bracket and motor/fan to unit and it works like its brand new. Thank you PartSelect!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Yelm, WA
Parts Used:
WP68233-3
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Refrigurator warm, would not cool. Freezer working fine.
All you need is a 1/4" nut driver or a 1/4" socket and ratchet. Remove the plastic cover to the freezer fan. remove cover to light fixture, bulb, pop out the light socket and remover 2 wires. Remove Ice maker by removing bottom screw and loosing the top 2 screws then lift up and out the ice maker enough to disconnect wiring harness. Revove 4 screws in back panel and the panel can be moved foward. Remove 2 screws holding the fan to the panel. Lay the fan on top of the cooling coil and remove ice maker electrical plug and the panel can be removed easely. Both the heating coil and thermostate switch are easly excessable.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Arlington, MA
Parts Used:
W11384469
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Both light bulbs had been replaced, but lights did not turn on.
I tried to remove the old light switch using a putty knife and a hammer. It was hard to compress the plastic tabs to pull it back through the hole, but all of a sudden, the lights came on. I guess banging on the switch freed-up the contacts. The new switch is now a spare part in case I need it.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cliff from Metairie, LA
Parts Used:
WP10097202
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
compressor will not start - when you turn it on - it hums for a few seconds and them you hear a click sound (the overload opens) and the hum stops
be sure the power cable is NOT plugged into an electrical outlet - removed the cover on the bottom rear of the refrigerator - using a flat blade screw driver pry the cover off the side of the compressor - remove the old relay - remove the wires from the old relay and install them on the new relay in the same location - install the new relay on the compressor connections - snap the cover back on the compressor - replace the cover - power the refrigerator on - the compressor should start and run normally
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from Paducah, KY
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
The freezer compartment was not cold enough.
I found the condenser fan was not working so I bought a new condenser fan kit and installed it. Fixed!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mary E. from Chicago, IL
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Frozen Lettuce In Crisper
My husband put in in, no problem and all is well. My husband is a mechanic for large machinery/motors so installation was no problem. Thanks, better than buying a new fridge!!!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chris from Greenville, OH
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers, Socket set
Condenser motor stopped working
Removed bad motor with socket set and pliers then removed the connectors from the old motor and soldered them on the new one. Then installed new motor. Works like new! Problem Solved! Easy fix!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Martin, TN
Parts Used:
WP68233-3
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Refrigerator was not staying cold enough. Coils in freezer not defrosting.
Unplugged the unit. Removed items from the freezer. Remove 2 phillip head screws from the cover over the coils. Defrosted the unit with a blow dryer. Upon completion of defrosting, put everything back together. Removed items and top shelf in refrigerator to gain access to the controls. Removed a 1/4 inch nut head screw and loosened 2 each phillip head screws. Unplug the controls from unit and placed on kitchen counter. Removed 3 each phillip head screws holding the timer in place and unplugged the timer. Installed new timer, connected everything back together and placed everything back into the refrigerator. Plugged the unit back up and it is now cooling and defrosting properly. This whole process took approximately 45 minutes.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the CT19X3V
91 - 105 of 162