CS20Y6W Crosley Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- David from Clintonville, WI
- Parts Used:
- WP61001846, WP52085-29
- Difficulty Level:
- Easy
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Screw drivers
Refridgerator constandly running
Turned out the defrost heater has burnt out in the freezer compartment on both heater tubes. To get to it. 1) take out all the shelves 2)remove the light bulb 3)unscrew 6 screws for back panel 4)Mine had a lot frost build up on the evaporator coils which I used a portable heater to defrost. which it took about 2 hrs to get all the frost thawed out. 5) Defrost heaters are located below each of the coils remove 2 screws on each plate there are 2 plates holding the heaters in place. 5) You may have to bend the sheet metal in order to get the heaters out and trace the wires to where it connects to towards the top or the freezer. 6) Put in the new heaters and plug in then put back together. 7) I also replaced the Defrost thermometer which it is easy to replaced while I had it apart. Now the fridge works perfect just like new.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Winston A from Brooklyn, NY
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- riley from CAVE CREEK, AZ
- Parts Used:
- WP65889-4
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from DAVISBURG, MI
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker stopped making ice
Remove 1 screw under ice maker. Gently pull downwards to unhook ice maker. Disconnected 4 pin wire connector. Remove and set aside the cover and wire loop you will need on new ice maker. Reverse the steps to install new maker. Once new ice maker is installed you will have to wait 2-4 hours for ice. There is a thermostat that will need to reach 10 degrees F to operate.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- bobbie from belleville, IL
- Parts Used:
- WP61001846
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers
Ice Build Up On Evap Coil
Removing the old heater coil was a bit of a task as you need to take off all the brackets holding the heater coil and then remove the wiring from back of the coil. Installing the new heater coil assembly in the brackets and feeding the wirings back up to the top was a major task. Need to have long arms as the heater is located way back in the freezer compartment. The part was the exact match. The part was delivered in 2 days. Thanks alot. Will use your site again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Aliki from Miami, FL
- Parts Used:
- WP628356
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Fill cup broke.
Very easy to order from parts select. Took seconds to replace.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jane from Albuquerque, NM
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Socket set
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- richard from colorado springs, CO
- Parts Used:
- D7824706Q
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Socket set
Ice maker stopped functioning
Part received was what I needed. There was one issue--the 'feed' opening to receive water and direct it into the ice tray was a side feed and what I needed was a back feed. That means I had to do some exchanging of parts to make it work. That exercise took more time that the actual installation.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rick from Livonia, NY
- Parts Used:
- WP61001846
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers
Freezer Cold With Ice Forming, Fresh Food Warm...Replacing Heater Elements.
1. Removed food from freezer and unplug refrigerator or shut circuit breaker. 2. Removed freezer shelves 3. Unscrew all screws on inside back wall and removed back wall plate. Run a fan to defrost the coils. 4. Unscrewed 4 heater bracket nuts on front of cooling coils and removed heater elements. Mine were burnt so I knew I had the correct part. 5. Removed the heater wires from back panel. 6. Install new heater elements being careful not to leave oils from hands on glass tubes and connected 2 wires from heating elements to rear panel. Reinstall nuts to hold heater brackets. 7. Plug in and run refrigerator for 2 hours with doors closed. Remove upper rear panel on fresh food side then use a flat head screwdriver to turn red timer screw above refrigerator thermostat clockwise slowly until compressor shuts down. 8. Open freezer and waited a few minutes to watch defrost heater coils glow. If they don't glow you might need a new thermostat for the freezer which is located on rear panel or a new timer. 9. Unplug and reinstall rear panel and shelves. Plug in. It will take 24 to 48hrs. For temperatures to level out. Good luck.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David P. from DINGMANS FRY, PA
- Parts Used:
- WP68233-3
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Freezer and food compartment not working!! Warm.
Spoke to Rep.Advised that several parts might be involved. Replaced 3 recommended parts and frig works like brand new. Saved hundreds of dollars in repairman costs.l. Plus $1000.00 for cost of new frig. If you can walk and chew gum at the same time? Easy fix. Very skilled Rep's!! Excellent service!! Great prices!! Highly recommend!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Gurnee, IL
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Old Ice Maker failed
I removed the old ice maker and during the short disassembly noticed a burned out connection to the heater element that allows the ice to be broken free of the tray and dumped into the bin. Part Select had a new unit to me next day! I had watched their short install video, and read some of the user comments, already. Re-installing the new unit was a snap, and just as the video had described except for the mount bracket. The only thing that concerned me was that the new unit did not immediately do anything. I began to investigate and found that the flexible water "chute" connection had ice in it! I unplugged the refer, unscrewed the water filter and drained it. I disconnected the water feed on the outside back of the unit as well to make sure water could flow easily to the ice maker port. I filled the water filter with boiling hot water and replaced it, I plugged in the refer, and reprogrammed the date and time. Several hours later I checked the ice maker and it was -- making ice!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Moore, OK
- Parts Used:
- D7824706Q
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
ice maker was over filling and causing water to flow into ice dispenser and freezing it al together
First turned off the water and unplugged the refrigerator and then removed the old ice maker by first removing the side cover plate and then next removed the ice level detector. Remove the screws that hold the ice maker in place and rotating it somewhat soas to gain access to the wires and then unplugged them. Next I had to modify the way the water comes into the new icemaker by adapting a CPVC street ell to fit into the hole on the side and then hook up the water supply. Installation is just the reverse of removal.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Hemet, CA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ross from Sun Lakes, AZ
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice cubes in bin frozen into big lumps due to water leaking into bin from icemaker. Lining of icemaker cube tray worn and damaged allowing leak.
Pull refrigerator out from wall to shut off water and power. Remove ice bin, pulling front down then out. Remove screw at bottom of icemaker, then pull down to release two clips, Pull out a couple inches to get hand behind icemaker to release wiring harness connector. (squeeze top and bottom to release clips). Remove unit. Remove wiring harness and wire bail from old unit and install on new unit. Reverse steps to install new unit. Make sure ice bin is fully inserted, or unit will not function.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Barbara H. from South Hill, VA
- Parts Used:
- WP65889-4
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
The refrigerator stopped running
I was told to order the run capacitor and the technician thought it would repair the refrigerator; but it did not. The appliance technician had to take the run capacitor off and install what he called a "hard start" and the refrigerator is operating right now.
Was this instruction helpful to you?
Thank you for voting!