Customer:
garth from forest lake, MN
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
My refrigerator stopped cooling and the freezer section stopped freezing
I knew the chances of all the freon leaking out was unlikely so I looked at the wiring to the compressor and there was a capacitor and a starter/overload so i figured I would start there. I went on line and found the parts at this site and they were less than the minimum service call charge for a service tech so I figured what the heck let's give her a shot so I did give it a shot. I ordered the parts and they were there in less time than a service tech could come out and i installed the parts and guess what for 90.00 in parts and 15 minutes in time I repaired my refrigerator. Thanks guys, It took less time to order the parts than it did to make the repair so thanks, your website rocks and is very well designed so my hat is off to you guys!
436 of 547 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gilbert from Clinton, MO
Parts Used:
W10613606, WP65889-4
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
The compressor would not run.
I removed the screws in the lower back panel where the compressor is located. Then I unplugged the capacitor and plugged the new one in. I then checked to see if the compressor would start. It wouldn't so I replaced the overload relay with capacitor and that fixed the problem. The capacitor just plugs into the relay then plugs into the compressor. There are several screws but all in all it is easy.
326 of 372 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Canyon Country, CA
Parts Used:
WP10442411
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Frig was hot freezer was cold. Freezer was fronzen over.
The frig was hot but the freezer was cold. I opened the back of the freezer and found the condenser all frozen over. Upon inspecting the defrost thermostat I found that it was split open, as if water got into it and the froze breaking it open. I used a blow dryer to defrost the condenser. I then spent a long time trying to find the model on-line, even the manufactor said it did not exist. Partselect.com was the only place that said the model did exist. When that part came in I toke the back of the freezer out again. Unplugged the defrost thermostat plugged the new one in clipped it back on the condenser and put the it all back together. Everything is working fine now.
100 of 104 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Clint from Rayville, MO
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Lights inside refrigerator not working
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.
136 of 249 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Denise from SOUTHINGTON, CT
Parts Used:
W10613606
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers
Frig not cold at all,Freezer was all defrosted
Well the frist thing I did was get out the all the paper work and look under trouble shooting.This frig has a list of codes to try to help narrow down what parts might be bad.Well at frist it seemed it was a Defrost Thermastat?Well thanks to PartSelect it showed me right where it was and step by step how to remove and replace it.It took me over 2Hr's,after that I let the frig run all night and the next morning(yep warm frig)not the part I needed,well now Im mad,the local part store said you need a 3in1 jump starter easy to in stall at $50.Can'nt bring parts back no way weather thier opened or not.So get home and can'nt see how this jumper is going to wire up to my compresser?So on to the Web site to get some info,find out that this part gets a thumb's down,it puts out more volt's then needed and kills your compresser the reviews where very help full.So back to PartSelect to see more info,then I spoted the Overload/Relay and went to the back of my Frig and this part just plugs right into the compresser,I pulled it of with pliers and Bingo a burn spot melted right through the Overload/Relay.Ordered the right part the same as the old one.Put the part in and Bam,compresser fired right up.If I only did alittle more home work I could off saved alot of head ach and money.Thanks PartSelect I'll alway's click on to your web site for future parts and advise.
64 of 70 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Anna from Lincoln, RI
Parts Used:
WPW10189190
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Our Refrigerator and freezer stopped working
I had read on a fix it site that the start device for the compressor on this particular model was known to fail after 3-5 years. When we received the part it looked like something that just plugged into the compressor. My husband unscrewed the panel in the back of the fridge and saw the part on the compressor. He first removed the three wires that it was connected to, and the wires were inside a plug so all he had to do was remove the plug from the start device. He then removed the old start device from the compressor. Plugged in the wire plug into the new start device, and pushed in the new start device into the compressor. There was also another black part plugged into the old start device that he plugged inot the new start device that connected to the compressor. Our freezer and refrigerator starting working. Within a couple of hours our freezer had made ice.
60 of 71 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
brice from irving, TX
Parts Used:
W10613606
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
compressor clicking but not turning on
I just opened up the fridge back panel accessed the old relay/capacitor, pulled it out, replaced with the new one, snapped it back into place, tested it (compressor came on), replaced the back panel and went on my way. Really, really easy repair.
45 of 55 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rodolfo from South San Francisco, CA
Parts Used:
W10613606, WP65889-4
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Refrigerator stopped cooling
Problem: My Maytag side by side door refrigerator just stopped cooling and has to discard all frozen items after I discovered being away for 3 days. First, I went to my computer and read some of the repair stories at Part Select “Need help with your repair?” and installation video guide.
1. I ordered the Refrigerator Adaptive Defrost Board (ADP) - followed the procedures how to disconnect and installed the new part. Unfortunately, it did not correct the problem and only warm is coming out.
2. I ordered the Defrost Heater Thermostat Assembly - removed the old and replaced with new assembly. Again, warm air coming out. Meanwhile, I kept on hearing “clicking sound every few second” not knowing where this coming from. Again, at Part Select, I read the story about it and I ordered the
Run Capacitor and the Overload/Relay with Capacitor. Soon as I opened the parts and tried to match it from the part at the back of the refrigerator and to the part from the compressor, I have discovered that they are not in compatible with the original parts from my Maytag Refrigerator and cannot be installed. And so I contacted (Email) Part Select customer service (Jeanette) if I could return the unused parts and had provided me the “Return address and the Reference Number”. This time, I gave Jeanette the Maytag Model and Serial numbers and asked where I could find this on my refrigerator and make the necessary repair and came back with the diagram and located #4 to the compressor. Ordered the correct part# PS2004058.
3. Upon receipt of the part above, I was puzzled, in the plastic container are four parts, included a plastic cover. I have not given up, I removed the original part encased in white plastic container pulled straight off the compressor and examined it closely. Before detaching all the wiring, I also noted before disconnecting from wire harness and read the Diagram/Instruction Sheet provided.
4. From the four new parts provided, installed the Overload Terminal, bottom part on Compressor with one terminal to the Blue wire. Connected White Jumper to the old harness. Lastly, I plugged the PTC Start Device (two terminals) above the Overload Terminal on the Compressor with the proper wiring as I previously noted and installed the electrical cover. “Plugged in the refrigerator to the power outlet”. To test the result, I left a glass of water inside the freezer and a bottle of wine into the refrigerator. The result - I checked after 2 hours, the water was frozen and a cool wine. “Little frustration included here, as I am not an electrician.” But now, I could say, I fixed it, and very proud of this accomplishment.
Thank You, PartSelect and to a great Customer Support!
Safety Note: Always make sure to unplugged the refrigerator (power off) prior doing the necessary repairs.
Rodolfo Julao/S. San Francisco, CA
42 of 48 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Davis Junction, IL
Parts Used:
WP10442411
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Refrigerator was warm, freezer was cold.
I removed the shelves from the freezer. I unscrewed 6 screws with a 1/4" nut driver and removed the back panel. The coil was solid ice because the defrost cycle wasn't working. I thawed the ice with a hairdryer (5 minutes), unplugged the thermostat and installed the new one (it simply clipped on to the coils), and reassembled the back panel and installed the shelves. Total time, about 14 minutes. Total cost, less than $20.00. I can't even get an appliance repairman to show up at my door for less than $100.00! Thanks to your website, I was able to diagnose my problem, order the correct part and fix it myself! (I bookmarked your site under my favorites). Thanks for this great consumer service. It's easy, inexpensive and quick to do it yourself!
39 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James Richard from St. Cloud, MN
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Light Switch broke
An easy job for smaller hands. Removed the two bolts holding the light cover. Removed two electrical connections from the old switch by pinching the retaining clip,removed the switch, snapped in the new one and re-attached the connectors. Your online illustrations helped me to know that the plastic housing for the light switch would only swing down so far and was not intended to be removed. Saved me from breaking that plastic cover's tabs. This home repair saved me more than 5 times the cost of hiring a professional to do it. Very happy homeowner.
48 of 76 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Serge from Richmond, CA
Parts Used:
WP10442411
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers, Socket set
Freezer was not defrosting and the refrigerator was warming up.
This is a bottom freezer refrigerator. First I unplugged the refrigerator. I then removed the wire shelf and wire tray from the freezer. I then removed the ice maker be removing the three screws that hold it in place. I then disconnected the icemaker electrical connector. I then removed the 7 screws that hold the panel at the back of the freezer revealing the evaporator and heat exchanger. I then unclipped the icemaker wiring harness from the panel. The whole evaporator/heat exchanger was buried in ice. I defrosted it with a hairdryer. This took about half an hour. The bi-metal thermostat is attached to the heat exchanger by a clip. Be sure to wear latex gloves to prevent cutting your fingers on the aluminum fins. I disconnected the electrical connectors and then carefully unclipped the thermostat. I discovered that the new thermostat had spade connectors where as the original had one spade connector and a bullet connector on the brown wire. I reused the original bullet connector by cutting it off the old thermostat and splicing it onto the new thermostat. I reversed the process for reassembly. There is no longer any ice build up and the refrigerator is working normally.
27 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Albany, OR
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The light switch on the refridgerator broke - no light.
Once I saw the replacement part I understood how to pry out the switch with a small screwdriver. Then just unplug the old one, plug in the new one and pop it into place.

The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.

I'm very pleased!
36 of 56 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dawn from Middleton, WI
Parts Used:
WPD7694803
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Broken refrigerator door handle
The part arrived in one day!!

First I removed the two screws that attached the handle to the door. Then I removed the white insert from the old handle and installed it on the new handle (4 screws involved). Last, I installed the new handle by attaching it with 2 screws. It was a breeze!
21 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fred from Niskayuna, NY
Parts Used:
WP10442411
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Refridgerator not cold becasue coils encased in ice
There is already a lot of good advice on this web site and others on how to diagnose and do this repair. I'll add a few additional comments that might be helpful.

I wanted to confirm that my old thermostat was in fact bad. I did this by disconnecting the two connectors and connecting them to each other to bypass the thermostat. This is like having the thermostat always closed. With the back panel still open so I could see the frozen coils I plugged the fridge back in and turned the defrost timer knob with a screwdriver to get to a defrost cycle. I could then see the heater element slowly melting the ice. This is of course not a safe way to operate the fridge. Over time this would get too hot and damage the food or worse. I only did this for a few minutes to see the system operating. I did not melt all the ice at that time. Also, it is of course dangerous to plug the fridge in with the panel open, so a great deal of caution is advised.

When I got my new thermostat I wanted to confirm that it worked before going through the install procedure. To do this I cooled it down and then used an ohm-meter to see that the circuit was closed. The important thing I found out is that ice-water, even 2 parts ice, one part cold water, was not cold enough to do this. Only when I put the thermostat into a cold freezer for a while did it get cold enough to close the circuit. I did this side by side with my old thermostat and saw that it was in face bad -it never closed the circuit.

This part from Part Select was an exact match for this freezer-on-bottom Whirlpool refrigerator. The connectors were identical so I did not have to solder wires together as others have need to do.

Some people get the ice off of the coils with a hair dryer. For me this could take half an hour. What worked better and much faster was spraying warm water on the ice with an old spray bottle. This adds extra water to the mix, but it did not overflow the drain pan. Even if it did, it would be easily mopped up if you can roll the fridge out.

One last thing. I suspect this thermostat broke in the winter, but with the dry air the fridge worked for a long time. Once summer hit and the house got humid, the coils iced up quickly.

Good Luck!
21 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Darrell from Hammond, LA
Parts Used:
WPW10189190
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Refrigerator not cooling, water dripping from doors
Water was dripping out of top freezer door and had water under the refridgerator. I could hear a clicking noice from bottom of refrigerator every 3-5 minutes.
After removing back panel, I noticed the fan was running and the clicking seemed to be coming from somewhere around the compressor which was warm. I noticed on the site a simular problem had been submitted. It said to remove the start relay and if it rattled it was bad. I removed two wires from it ( it is connected onto the side of the compressor) then took a small screw driver to pry it away from the compressor. It not only rattled but had tiny pieces falling out. I ordered the part and replaced it in less than 15 minutes total and all is well.
21 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!