- Customer:
- JAMES from Middleboro, MA
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from West Warwick, RI
- Parts Used:
- W11396033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
broken light switch
followed the instructions provided and that's it!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from Newton Grove, NC
- Parts Used:
- W11396033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Light switch rocker broke, disabling freezer internal light, water dispenser, and ice dispenser
Very simple. Matched female plugs with respective male color coded prong; pushed together then inserted unit in slot of freezer sidewall and rotated into position...job done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Glenwood, MN
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers
fan had stopped-freezer not performing etc.
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- robert from central point, OR
- Parts Used:
- W10613606
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Fridge random humming
Unscrewed back of fridge and unplugged relay from compressor and plugged in the new one remember that the new one turns 180 degrees from existing switch.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Miriam from Canyon Country, CA
- Parts Used:
- W10613606
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
No cooling, compressor not running and was very hot
Plied off the relay switch with a screw driver. I could not pull it off by hand. Disconnected the wires to it and replaced with new part. Had problem getting the part back on and lining up the pins with the connector. I had to line up one pin and start at an angle and roll the part onto the contact pins.
I was impressed with the one day delivery without paying because it was shipped from a warehouse in California where the repair was made.
I was impressed with the one day delivery without paying because it was shipped from a warehouse in California where the repair was made.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from SAN SABA, TX
- Parts Used:
- WPW10503278, W11619328
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Refrigerator would not cool,freezer worked.
Took too panel down. Remove.bulbs . Unplugged refrigerator. Removed electronic control board .installed new electronic control board. Plugged in refrigerator , programmed control for ice in about 1 hour refrigerator went to work and got cold Simple operation. Donald Harrell, Don's Repair Service .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Fidel from Forest, MS
- Parts Used:
- WPW10128551
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Refrigerator wouldn't cool
First I removed the six screws from the cover. I then disconnected the two wires and pulled the small motor out with its base and removed two screws that hold it in place. I then changed the old one for the new one and set it back in its place. I then set the cover back and turned it on. I was happy again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Pennsylvania Furnace, PA
- Parts Used:
- D7824706Q
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Ice maker leaked water
Overall, replacing the ice maker wasn't too bad but it wasn't nearly as easy for me as it seems to have been for some. In my case, the fridge was an Amana and the ice maker was mounted in such a way that disconnecting the power connector was difficult. The ice maker had to be completely dismounted before any access to the power connector was even possible. The short power cables made it very difficult to get the ice maker into a position where I had a good view of the power connector enabling me to see how to release it. The only other challenge was the cup that the water line goes into. The replacement ice maker did not come with the right cup - the instructions said to replace the provided one with the old one. No instructions for this procedure were provided and it looked to me like it might involve significant disassembly, something I wanted to avoid for fear of breaking a plastic part on the new ice maker (something I had already done when disassembling the old ice maker). So instead of replacing the cup, I modified the new one to match the old one. This involved removing a cutout on one side and covering a hole on the other. Installation of the new ice maker went fine and the water leak problem was fixed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronald from Marion, IL
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
didn't eject icecubes
R & R Icemaker Assembly. Took out 3 screws and unpluged Icemaker & replaced with new part. very easy and the service from PartSelect was fantastic.
Very Satisfied,
Ron Martin
Very Satisfied,
Ron Martin
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alvin from ORANGE PARK, FL
- Parts Used:
- W10613606
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Socket set
Power surge cause compressor to stop functioning
Followed the YouTube video linked to the Compressor Start Device and Capacitor I purchased. The repair was just as easy as the technician in the video said it would be. Removed the back panel, remove the clamp, worked the Compressor Start Device and Capacitor off the electrical prongs and replace it with the new one. After I reassemble the refrigerator, it was fully operational. Very easy to do and only required a few tools.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Tucson, AZ
- Parts Used:
- 12001937
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
evaporator coil in freezer section fozen solid, refer not cool
To remove freezer door, push white tabs, inside rail toward back, remove door and rails as one unit. Unscrew plastic rail support on one side, remove ice maker, then back panel. Cut off thermostat, strip old leads, match colors, twist copper wires together, then crimp on new part using connectors provided. Reassemble, hardest part was figuring out how to remove freezer door. Check for continuity between heater lead and white terminal of icemaker plug just to make sure the heater is good while everything is apart.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rich from Monon, IN
- Parts Used:
- W10613606
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Compressor would not start
Removed back access cover with quarter inch nut driver, unplugged wire harness, pulled old relay out & plugged in new one, reconnected wire harness, and reinstalled access cover. Piece of cake. (Shipping was very quick) ***Frig was only 3yr an 1 mounth old.*** Maytag - Dependable Huh?
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- BRUCE from AMMON, ID
- Parts Used:
- W10613606
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Not freezing or keeping thing cold in fridge
Once I got the right part the repair was quick and easy. All I had to do is get the old part off with a screwdriver and curved needle nose pliers and the old part came right off. The new part went in just as easy. Quick and easy. Less than 15 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- walter from crete, IL
- Parts Used:
- WP67006704
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The glass shattered in a 1000 pieces during a mild cleaning!
These guys had my part mailed in lighting fast! It arrived in 2 days in a padded box in perfect shape.The price was the best on line and they saved my life one day before thansgiving!! They got my vote and respect! Great job partselect!!! walt , crete illinois
Was this instruction helpful to you?
Thank you for voting!